合成2D乳腺摄影与常规2D数字乳腺摄影联合3D断层摄影的诊断准确性比较

Accuracy of Synthetic 2D Mammography Compared With Conventional 2D Digital Mammography Obtained With 3D Tomosynthesis.
PubMed 文献 · AJR Am J Roentgenol · 2019-03-27

本研究回顾性纳入筛查乳腺摄影中经活检证实的乳腺癌89例及随访365天后阴性或良性(BI-RADS 1或2类)100例,由三名盲法阅片者分别评估DBT联合合成2D与DBT联合FFDM的BI-RADS分类及恶性概率。结果显示两种方案在敏感度、特异度、阳性预测值、阴性预测值及AUC上均无统计学显著差异;作者认为DBT联合合成2D表现不劣于DBT联合FFDM,可能作为降低辐射剂量的可行替代方案。

要点

  • DBT联合合成2D与DBT联合FFDM在敏感度、特异度、PPV、NPV上均无统计学显著差异。
  • 各阅片者两种方案的恶性概率AUC均无统计学显著差异。
  • 作者认为DBT联合合成2D可能作为降低辐射剂量的可行替代方案。

核心结论

  • DBT联合合成2D乳腺摄影在诊断准确性指标上表现与DBT联合FFDM相当且不更差,可能作为降低辐射剂量而不牺牲诊断性能的可行替代方案。

研究设计与样本

  • 回顾性研究,纳入筛查乳腺摄影中经活检证实的乳腺癌89例及随访365天后阴性或良性(BI-RADS 1或2类)100例,由三名盲法阅片者分别评估DBT联合合成2D与DBT联合FFDM并分配BI-RADS分类及恶性概率。

诊断标准与关键数值

  • 以活检证实的乳腺癌及随访365天阴性或良性(BI-RADS 1或2类)为参考标准,计算敏感度、特异度、阳性预测值、阴性预测值。
  • 以ROC分析估计恶性概率的AUC评估阅片者性能。
  • DBT联合合成2D与DBT联合FFDM在敏感度、特异度、阳性预测值、阴性预测值上均无统计学显著差异。
  • 各阅片者两种方案的恶性概率AUC均无统计学显著差异。

临床应用与阅片要点

  • 作者认为DBT联合合成2D乳腺摄影可能作为降低辐射剂量的可行替代方案,而不牺牲诊断性能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to compare the diagnostic performance of synthetic 2D imaging generated from 3D tomosynthesis (DBT) with traditional 2D full-field digital mammography (FFDM) by use of the most up-to-date software algorithm in an urban academic radiology practice. MATERIALS AND METHODS. The records of patients undergoing screening mammography with DBT, synthetic 2D imaging, and FFDM between August 13, 2014, and January 31, 2016, were retrospectively collected. The cohort included all biopsy-proven breast cancers detected with screening mammography during the study period (n = 89) and 100 cases of negative or benign (BI-RADS category 1 or 2) findings after 365 days of follow-up. In separate sessions, three readers blinded to outcome reviewed DBT plus synthetic 2D or DBT plus FFDM screening mammograms and assigned a BI-RADS category and probability of malignancy to each case. The diagnostic performance of each modality was assessed by calculating sensitivity and specificity. Reader performance was assessed by ROC analysis to estimate the AUC of the likelihood of malignancy. RESULTS. No statistically significant difference was found in diagnostic accuracy (sensitivity, specificity, positive predictive value, or negative predictive value) between DBT plus synthetic 2D mammography and DBT plus FFDM. There was no statistically significant difference between the AUC of DBT plus synthetic 2D mammography and the AUC of DBT plus FFDM for any reader. CONCLUSION. DBT plus synthetic 2D mammography performs as well as and not worse than DBT plus FFDM in measures of diagnostic accuracy and may be a viable alternative for decreasing radiation dose without sacrificing diagnostic performance.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Simon K, Dodelzon K, Drotman M, et al. Accuracy of Synthetic 2D Mammography Compared With Conventional 2D Digital Mammography Obtained With 3D Tomosynthesis. AJR Am J Roentgenol. 2019. PMID: 30917028. doi:10.2214/AJR.18.20520

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。