乳腺肿块彩色多普勒超声的多中心前瞻性研究:本课题组彩色多普勒方法的效用
日本16家机构对1408个乳腺实性肿块(恶性839个、良性569个)行彩色多普勒超声评估,多因素分析示血管丰富度、血管流型(边缘环绕血流或穿入血流)及穿入血流入射角为鉴别良恶性的显著征象;但B模式单独与加用彩色多普勒的敏感度(97.6%→97.9%)和特异度(38.3%→41.5%)无显著改善。模拟实验提示考虑年龄后特异度显著提高(38.3%→46.0%,p<0.001),据此改进了诊断标准。
要点
- 血管丰富度、边缘环绕血流或穿入血流及穿入血流入射角为鉴别乳腺良恶性的显著征象。
- B模式加用彩色多普勒后敏感度97.6%→97.9%、特异度38.3%→41.5%,无显著改善。
- 模拟实验提示考虑年龄后特异度由38.3%升至46.0%(p<0.001),据此改进诊断标准。
核心结论
- 多因素分析示血管丰富度、血管流型(边缘环绕血流或穿入血流)及穿入血流入射角为鉴别乳腺良恶性的显著征象;B模式加用彩色多普勒未显著改善敏感度和特异度,模拟实验提示考虑年龄后特异度显著提高并据此改进诊断标准。
研究设计与样本
- 日本16家机构的多中心前瞻性研究(JABTS BC-04研究),纳入1408个乳腺实性肿块(恶性839个、良性569个),评估彩色多普勒超声图像。
关键影像表现/征象
- 血管丰富度(血流量)为鉴别乳腺良恶性的显著征象。
- 血管流型为「边缘环绕血流」或「穿入血流」为鉴别良恶性的显著征象。
- 穿入血流的入射角为鉴别良恶性的显著征象。
诊断标准与关键数值
- B模式单独与加用彩色多普勒的敏感度分别为97.6%与97.9%,特异度分别为38.3%与41.5%。
- 模拟实验提示考虑年龄后特异度由38.3%升至46.0%(p<0.001)。
局限性
- 原文指出在评估血管丰富度时应考虑年龄。
- 原文为探索上述阴性结果的原因并改进诊断标准而进行了模拟实验。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The use of color Doppler ultrasound (CD) for distinguishing between benign and malignant breast lesions remains controversial. This study (JABTS BC-04 study) was aimed at confirming the usefulness of our CD diagnostic criteria. We evaluated ultrasound images of 1408 solid breast masses from 16 institutions in Japan (malignant: 839, benign: 569). Multivariate analysis indicated that vascularity (amount of blood flow), vascular flow pattern ("surrounding marginal flow" or "penetrating flow") and the incident angle of penetrating flow were significant findings for distinguishing between benign and malignant lesions. However, the sensitivity and specificity of B-mode alone did not improve significantly with CD addition (97.6% → 97.9%, 38.3% → 41.5%, respectively). We explored the causes of these negative results and found that age should have been considered when evaluating vascularity. Simulation experiments suggested that specificity is significantly improved when age is taken into consideration (38.3% → 46.0%, p < 0.001) and we thereby improved our diagnostic criteria.
引用
- Watanabe T, Kaoku S, Yamaguchi T, et al. Multicenter Prospective Study of Color Doppler Ultrasound for Breast Masses: Utility of Our Color Doppler Method. Ultrasound Med Biol. 2019. PMID: 30905536. doi:10.1016/j.ultrasmedbio.2019.01.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。