浸润性乳腺癌的肿瘤-间质比(TSR):与多参数乳腺MRI表现的相关性
本研究纳入126例经手术证实的浸润性乳腺癌患者,分析肿瘤-间质比(TSR)与MRI表现的相关性。高间质组(>50%)的STIR信号强度及病灶/肌肉信号比(L/M ratio)显著低于低间质组(<50%),且高间质组廓清型强化模式比例显著更低、持续型强化模式比例显著更高。TSR与ADC值无显著相关性。
要点
- 高间质组(>50%)STIR信号强度和L/M比值显著低于低间质组(<50%)。
- 高间质组廓清型强化模式比例显著低于低间质组,持续型强化模式比例显著高于低间质组。
- TSR与ADC值之间无显著相关性。
核心结论
- 乳腺MRI的STIR序列和动态增强序列可反映浸润性乳腺癌的间质成分。
研究设计与样本
- 经机构审查委员会批准,连续纳入126例经手术证实的浸润性乳腺癌患者,所有患者均行乳腺MRI检查,包括STIR T2加权成像、扩散加权成像(DWI)和增强后动态成像;测量每个病灶的平均信号强度(SI)和表观扩散系数(ADC)值,并计算病灶信号强度与肌肉信号强度的比值(L/M ratio)以及动态图像的动力学参数百分比;TSR定义为间质成分的百分比,分为高间质组(>50%)和低间质组(<50%)。
关键影像表现/征象
- 高间质组(>50%)的SI显著低于低间质组(<50%)(208.64 vs 331.86,p < 0.001)。
- 高间质组(>50%)的L/M ratio显著低于低间质组(<50%)(5.69 vs 9.31,p < 0.001)。
- 高间质组(>50%)廓清型强化模式百分比显著低于低间质组(<50%)(25% vs 34.7%,p = 0.012)。
- 高间质组(>50%)持续型强化模式百分比显著高于低间质组(<50%)(36.92% vs 28.26%,p = 0.044)。
诊断标准与关键数值
- TSR定义为间质成分的百分比,分为高间质组(>50%)和低间质组(<50%)。
- 高间质组SI为208.64,低间质组SI为331.86(p < 0.001)。
- 高间质组L/M ratio为5.69,低间质组L/M ratio为9.31(p < 0.001)。
- 高间质组廓清型强化模式百分比为25%,低间质组为34.7%(p = 0.012)。
- 高间质组持续型强化模式百分比为36.92%,低间质组为28.26%(p = 0.044)。
临床应用与阅片要点
- STIR序列和动态增强序列可用于评估浸润性乳腺癌的间质成分。
- TSR与ADC值之间无显著相关性,ADC值可能不反映肿瘤间质成分。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To correlate the tumor-stromal ratio (TSR) of invasive breast cancer and MRI findings.
METHODS: This study was approved by our institutional review board. 126 consecutive patients with surgically proven invasive breast cancer were included. All patients underwent MRI exams including short-tau inversion-recovery (STIR) T 2 weighted imaging, diffusion-weighted imaging (DWI) and post-contrast dynamic imaging. The mean signal intensity (SI) and apparent diffusion coefficient (ADC) value of each lesion were measured. To objectively evaluate the STIR images, the ratio of the SI of the lesion to the muscle (L/M ratio) was also measured. Percentages of MRI kinetic parameters obtained from dynamic images were also measured. The TSR was defined as the percentage of the stromal component, and categorized into high-stroma (> 50%) and low-stroma (< 50%) groups. Intergroup differences in the SI, L/M ratio, ADC value and percentages of kinetic parameters were examined.
RESULTS: The SI and L/M ratio of the high-stroma group were significantly lower than those of the low-stromal group (208.64 vs 331.86 for SI, 5.69 vs 9.31 for L/M ratio) (p < 0.001). The high-stroma group had significantly lower percentages of a washout pattern (25% vs 34.7 %) (p = 0.012) and significantly higher percentages of a persistent pattern (36.92% vs 28.26 %) (p = 0.044). There were no significant correlations between the TSR and ADC value.
CONCLUSION: STIR and dynamic sequence of breast MRI reflects the stromal component of invasive breast cancer.
ADVANCES IN KNOWLEDGE: This is the first study to correlate TSR and MRI findings. STIR and post-contrast dynamic study correlated with the stromal component of breast cancer.
引用
- Yamaguchi K, Hara Y, Kitano I, et al. Tumor-stromal ratio (TSR) of invasive breast cancer: correlation with multi-parametric breast MRI findings. Br J Radiol. 2019. PMID: 30835501. doi:10.1259/bjr.20181032
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。