利用高帧率超声与光学显微镜定量汽化靶向纳米液滴

Quantification of Vaporised Targeted Nanodroplets Using High-Frame-Rate Ultrasound and Optics.
PubMed 文献 · Ultrasound Med Biol · 2019-02-28

本研究在体外将叶酸受体靶向与非靶向纳米液滴与MDA-MB-231乳腺癌细胞共孵育,于超声激活后即刻用高帧率超声联合光学显微镜评估汽化纳米液滴的声学响应与尺寸分布。结果显示靶向纳米液滴的声学信号持续时间更长、附着于细胞的汽化液滴数量更多且尺寸更大。

要点

  • 高帧率超声可定量汽化纳米液滴的声学信号衰减与尺寸分布。
  • 靶向纳米液滴激活后1秒仍有70%声学信号,非靶向仅40%。
  • 光学显微镜显示靶向组附着细胞的汽化液滴数量约为非靶向组的6倍。

核心结论

  • 高帧率超声联合光学显微镜可评估靶向与非靶向纳米液滴汽化后的尺寸与声学响应差异,有助于优化影像与治疗应用的方法学设计。

研究设计与样本

  • 体外研究,将叶酸受体靶向与非靶向纳米液滴与MDA-MB-231乳腺癌细胞共孵育,超声激活后即刻用高帧率超声、流速映射技术、斯托克斯理论与光学显微镜评估汽化纳米液滴。

关键影像表现/征象

  • 漂浮的汽化纳米液滴平均比附着于细胞的汽化纳米液滴大7倍以上。
  • 靶向汽化纳米液滴激活后1秒仍有70%声学信号,非靶向仅40%。
  • 光学显微镜显示靶向组附着细胞的汽化纳米液滴平均多6倍,直径范围4至68微米;非靶向组直径范围1至7微米。
  • 附着于细胞的靶向汽化纳米液滴平均尺寸约为非靶向组的3倍。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Molecular targeted nanodroplets that can extravasate beyond the vascular space have great potential to improve tumor detection and characterisation. High-frame-rate ultrasound, on the other hand, is an emerging tool for imaging at a frame rate one to two orders of magnitude higher than those of existing ultrasound systems. In this study, we used high-frame-rate ultrasound combined with optics to study the acoustic response and size distribution of folate receptor (FR)-targeted versus non-targeted (NT)-nanodroplets in vitro with MDA-MB-231 breast cancer cells immediately after ultrasound activation. A flow velocity mapping technique, Stokes' theory and optical microscopy were used to estimate the size of both floating and attached vaporised nanodroplets immediately after activation. The floating vaporised nanodroplets were on average more than seven times larger than vaporised nanodroplets attached to the cells. The results also indicated that the acoustic signal of vaporised FR-targeted-nanodroplets persisted after activation, with 70% of the acoustic signals still present 1 s after activation, compared with the vaporised NT-nanodroplets, for which only 40% of the acoustic signal remained. The optical microscopic images revealed on average six times more vaporised FR-targeted-nanodroplets generated with a wider range of diameters (from 4 to 68 µm) that were still attached to the cells, compared with vaporised NT-nanodroplets (from 1 to 7 µm) with non-specific binding after activation. The mean size of attached vaporised FR-targeted-nanodroplets was on average about threefold larger than that of attached vaporised NT-nanodroplets. Taking advantage of high-frame-rate contrast-enhanced ultrasound and optical microscopy, this study offers an improved understanding of the vaporisation of the targeted nanodroplets in terms of their size and acoustic response in comparison with NT-nanodroplets. Such understanding would help in the design of optimised methodology for imaging and therapeutic applications.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Zhang G, Lin S, Leow CH, et al. Quantification of Vaporised Targeted Nanodroplets Using High-Frame-Rate Ultrasound and Optics. Ultrasound Med Biol. 2019. PMID: 30827708. doi:10.1016/j.ultrasmedbio.2019.01.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。