文献速递泌尿生殖US

经直肠实时剪切波弹性成像测量前列腺硬度用于前列腺癌检测的可行性研究

Stiffness of prostate gland measured by transrectal real-time shear wave elastography for detection of prostate cancer: a feasibility study.
PubMed 文献 · Br J Radiol · 2019-03-26

本研究纳入215例患者,在经直肠超声引导活检前于六个相同平面行剪切波弹性成像,以全前列腺杨氏模量均值与病理结果比较。恶性病变的杨氏模量最大值、均值、最小值均显著高于良性病变(均p<0.05),全前列腺杨氏模量可用于鉴别良恶性前列腺病变。

要点

  • 恶性前列腺病变的杨氏模量最大值、均值、最小值均显著高于良性病变(均p<0.05)。
  • 前列腺癌最佳截断值:杨氏模量最大值128.48 kPa、均值62.27 kPa、最小值20.03 kPa。
  • 全前列腺杨氏模量越高,前列腺特异抗原和Gleason评分越高。

核心结论

  • 全前列腺杨氏模量可用于鉴别良性与恶性前列腺病变,杨氏模量越高恶性病变风险越高且与更高的前列腺特异抗原和Gleason评分相关。

研究设计与样本

  • 可行性研究,215例患者,在经直肠超声引导活检前于六个相同平面行经直肠实时剪切波弹性成像,以活检病理结果为参考标准。

诊断标准与关键数值

  • 前列腺癌最佳截断值:杨氏模量最大值128.48 kPa,敏感度77.88%,特异度85.33%。
  • 前列腺癌最佳截断值:杨氏模量均值62.27 kPa,敏感度81.42%,特异度74.51%。
  • 前列腺癌最佳截断值:杨氏模量最小值20.03 kPa,敏感度60.18%,特异度63.73%。
  • 前列腺特异抗原与杨氏模量最大值和均值正相关(r=0.686和0.678)。
  • Gleason评分与杨氏模量最大值和均值正相关(r=0.410和0.382)。

临床应用与阅片要点

  • 剪切波弹性成像可量化全前列腺硬度,无论病变在灰阶和彩色多普勒超声上是否可见,均可用于检测前列腺癌。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to evaluate the value of the Young's modulus obtained by transrectal real-time shear wave elastography (SWE) for detection of prostate cancer (PCa).

METHODS: 215 patients underwent SWE in six identical planes before biopsy guided with transrectal ultrasonography. The Young's modulus of the entire prostate gland was defined as the mean of the results in these planes. The measurements were compared with the pathological results, the prostate specific antigen (PSA), and the Gleason score (GS) after biopsy.

RESULTS: The Young's modulus of elasticity, including the maximum Young's modulus (Emax), the mean Young's modulus (Emean), and the minimum Young's modulus (Emin), were significantly higher in malignant lesions than those in benign lesions (all p < 0.05). The optimal cut-off values for PCa were 128.48 kPa, 62.27 kPa, and 20.03 kPa, respectively. The sensitivities were 77.88%, 81.42%, and 60.18%, respectively, and the specificities were 85.33%, 74.51 and 63.73 %, respectively. PSA positively correlated with Emax and Emean (r = 0.686 and 0.678, respectively), as did the GS (r = 0.410 and 0.382, respectively).

CONCLUSION: The Young's modulus of entire prostate gland can be used to differentiate benign from malignant prostatic lesions. There were higher Young's modulus of elasticity and higher risk of malignant lesions. Meanwhile, higher Young's modulus correlated with higher PSA and GS.

ADVANCES IN KNOWLEDGE: This study indicates SWE can detect PCa by quantified the stiffness of entire prostate gland whether the lesions have been visible or not on gray-scale and Doppler ultrasound.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Ji Y, Ruan L, Ren W, et al. Stiffness of prostate gland measured by transrectal real-time shear wave elastography for detection of prostate cancer: a feasibility study. Br J Radiol. 2019. PMID: 30875242. doi:10.1259/bjr.20180970

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。