文献速递泌尿生殖腹部MR

前列腺癌MRI:计算高b值DWI能否替代原生采集?

MRI for prostate cancer: can computed high b-value DWI replace native acquisitions?
PubMed 文献 · Eur Radiol · 2019-03-18

在124例疑似前列腺癌男性中,比较由低b值DWI(100、400、800 s/mm²)经单指数扩散衰减模型计算得到的高b值DWI(2000和2500 s/mm²)与直接采集的高b值DWI(2000 s/mm²),评估图像质量和肿瘤检出率。计算DWI整体图像质量评分更高但鬼影加重;在63例接受活检的患者中检出率相似,肿瘤清晰度计算DWI更优(p<0.001);不采集高b值原生DWI每例节省220秒采集时间。

要点

  • 计算高b值DWI(2000和2500 s/mm²)由b值100、400、800 s/mm²图像经单指数扩散衰减模型生成。
  • 在63例活检患者中,计算DWI与原生高b值DWI的前列腺癌检出率相似。
  • 计算DWI整体图像质量评分高于原生高b值DWI,但鬼影加重。

核心结论

  • 计算高b值DWI在保持前列腺癌检出率相当的同时大幅缩短采集时间,并改善整体图像质量。

研究设计与样本

  • 124例连续疑似前列腺癌男性在3.0 T MR系统使用32通道相控阵体线圈行诊断性前列腺MRI,其中63例接受前列腺活检;MRI方案包括3D T2w、高分辨率FOCUS™ DWI(b值100、400、800、2000 s/mm²)和动态对比增强图像;由低b值DWI经单指数扩散衰减模型生成b值2000和2500 s/mm²的计算DWI;由四名放射科医师比较计算DWI与原生高b值DWI(2000 s/mm²)的图像质量和肿瘤清晰度。

关键影像表现/征象

  • 计算DWI整体图像质量评分高于原生高b值DWI,但鬼影加重。
  • 计算DWI背景信号抑制更好。
  • 计算DWI对可疑病灶的清晰度更优(p<0.001)。
  • 计算DWI与原生高b值DWI在前列腺癌检出率上相似。

诊断标准与关键数值

  • 计算DWI b值2000和2500 s/mm²由b值100、400、800 s/mm²图像经单指数扩散衰减模型生成。
  • 原生高b值DWI b值为2000 s/mm²。
  • 图像质量从背景信号抑制、解剖清晰度、鬼影、变形四方面评价。
  • 肿瘤清晰度计算DWI优于原生高b值DWI,p<0.001。

临床应用与阅片要点

  • 计算高b值DWI可替代原生高b值DWI,每例减少采集时间220秒。
  • 阅片时注意计算DWI鬼影较原生高b值DWI加重。
  • 计算DWI背景实质抑制更好,有助于突出可疑病灶。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare computed high b-value diffusion-weighted images (c-DWI) derived from low b-value DWI images and acquired high b-value DWI (a-DWI), in overall image quality and prostate cancer detection rate.

MATERIALS AND METHODS: A total of 124 consecutive men with suspected prostate cancer (PCa) underwent diagnosis prostate MRI on a 3.0 T MR system using a 32-channel phased-array torso coil. Among them, 63 underwent prostate biopsy. MRI protocol included 3DT2w images, high resolution Fov Optimized and Constrained Undistorted Single-Shot (FOCUS™) DWI images with b-values of 100, 400, 800, and 2000 s/mm2 and dynamic contrast enhanced images. C-DWI images (2000 and 2500 s/mm2) were derived from the three lower acquired b-value DWI images using a mono-exponential diffusion decay. C-DWI and acquired high b-value DWI (a-DWI) (2000 s/mm2) were compared for image quality (background signal suppression, anatomic clarity, ghosting, distortion) and tumor conspicuity by four radiologists.

RESULTS: C-DWIs demonstrated higher rating than a-DWIs for overall image quality despite worsened ghosting. In patients with a biopsy, similar detection rate was observed while conspicuity was better with c-DWI (p < 0.001). Non-acquisition of high b-value a-DWI reduced total acquisition time by 220 s per patient.

CONCLUSION: C-DWI provides a substantial reduction in acquisition time while maintaining comparable prostate cancer detection rate and improving global image quality.

KEY POINTS: • Computed DWI improves global quality of prostate MRI. • Computed DWI improves analysis of DWI images with decrease acquisition time. • Computed DWI provides greater background suppression of parenchyma and improves conspicuity of suspicious lesion.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Jendoubi S, Wagner M, Montagne S, et al. MRI for prostate cancer: can computed high b-value DWI replace native acquisitions? Eur Radiol. 2019. PMID: 30887197. doi:10.1007/s00330-019-06085-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。