文献速递腹部MR

以组织学为参考标准评估肝脏磁共振质子密度脂肪分数对肝脂肪变性的诊断准确性:一项Meta分析

Diagnostic accuracy of hepatic proton density fat fraction measured by magnetic resonance imaging for the evaluation of liver steatosis with histology as reference standard: a meta-analysis.
PubMed 文献 · Eur Radiol · 2019-03-15

该Meta分析纳入13项研究共1100例受试者,以组织学为参考标准评估MRI-PDFF对肝脂肪变性的诊断准确性。LS≥G1、LS≥G2和LS=G3的AUC分别为0.98、0.91和0.92;LS≥G2和LS=G3的汇总敏感度分别为0.83和0.79,汇总特异度均为0.89。结论认为MRI-PDFF在检测和分级肝脂肪变性方面具有高诊断准确性。

要点

  • MRI-PDFF对LS≥G2和LS=G3的汇总敏感度分别为0.83和0.79,汇总特异度均为0.89。
  • LS≥G1、LS≥G2和LS=G3的AUC分别为0.98、0.91和0.92。
  • LS≥G1存在显著阈值效应,未计算其汇总敏感度和特异度。

核心结论

  • MRI-PDFF以组织学为参考标准检测和分级肝脂肪变性具有高诊断准确性,提示其能在临床试验和患者诊疗中提供肝脂肪变性的准确定量。

研究设计与样本

  • 系统检索文献后纳入13项研究共1100例受试者,采用QUADAS-2进行质量评价,分别计算LS≥G1、LS≥G2和LS=G3的不一致指数,以汇总受试者工作特征曲线下面积(AUC)作为诊断准确性指标,无阈值效应时计算汇总敏感度和特异度。

诊断标准与关键数值

  • LS≥G1的AUC为0.98(95%CI 0.76,1.00),存在显著阈值效应。
  • LS≥G2的AUC为0.91(95%CI 0.89,0.94),汇总敏感度0.83(95%CI 0.75,0.88),汇总特异度0.89(95%CI 0.84,0.92)。
  • LS=G3的AUC为0.92(95%CI 0.89,0.94),汇总敏感度0.79(95%CI 0.63,0.90),汇总特异度0.89(95%CI 0.84,0.92)。

临床应用与阅片要点

  • 作者认为MRI-PDFF能在临床试验和患者诊疗中提供肝脂肪变性的准确定量。

局限性

  • LS≥G1存在显著阈值效应。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this meta-analysis was to evaluate the diagnostic accuracy of hepatic magnetic resonance imaging-proton density fat fraction (MRI-PDFF) for the assessment of liver steatosis (LS) with histology as reference standard.

METHODS: A systematic literature search was performed to identify pertinent studies. Quality analyses were conducted by Quality Assessment of Diagnostic Accuracy Studies-2. Diagnostic data were extracted and inconsistency index was calculated for LS≥G1, LS≥G2, and LS=G3, respectively. The area under summary receiver operating characteristic curve (AUC) served as the indicator of diagnostic accuracy. The pooled sensitivity and specificity were calculated if threshold effect was absent.

RESULTS: Thirteen studies containing 1100 subjects were included. There was significant threshold effect for LS≥G1. The AUCs for LS≥G1, LS≥G2, and LS=G3 were 0.98 (95% confidence interval (CI) 0.76, 1.00), 0.91 (95% CI 0.89, 0.94), and 0.92 (95% CI 0.89, 0.94), respectively. The pooled sensitivities for LS≥G2 and LS=G3 were 0.83 (95% CI 0.75, 0.88) and 0.79 (95% CI 0.63, 0.90), respectively; the pooled specificities for LS≥G2 and LS=G3 were 0.89 (95% CI 0.84, 0.92) and 0.89 (95% CI 0.84, 0.92), respectively.

CONCLUSIONS: MRI-PDFF has high diagnostic accuracy at detecting and grading LS with histology as reference standard, suggesting that MRI-PDFF is able to provide an accurate quantification of LS in clinical trials and patient care.

KEY POINT: • MRI-PDFF is able to provide an accurate quantification of LS in clinical trials and patient care.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Qu Y, Li M, Hamilton G, et al. Diagnostic accuracy of hepatic proton density fat fraction measured by magnetic resonance imaging for the evaluation of liver steatosis with histology as reference standard: a meta-analysis. Eur Radiol. 2019. PMID: 30877459. doi:10.1007/s00330-019-06071-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。