文献速递妇产影像US

妊娠32周与36周常规超声检查对小于胎龄儿的预测

Routine ultrasound at 32 vs 36 weeks' gestation: prediction of small-for-gestational-age neonates.
PubMed 文献 · Ultrasound Obstet Gynecol · 2019-04-30

这项前瞻性研究纳入21 989例在31+0至33+6周和45 847例在35+0至36+6周接受常规超声的単胎妊娠,比较估测胎儿体重(EFW)与腹围(AC)预测小于胎龄儿(SGA)的效果。结果显示35+0至36+6周筛查的AUC显著高于31+0至33+6周,EFW Z评分优于AC Z评分;35+0至36+6周以EFW<第10百分位预测2周内分娩的出生体重<第10和第3百分位SGA的检出率分别为70%和84%,若需检出>85%的出生体重<第10百分位SGA则需采用EFW<第40百分位。

要点

  • 35+0至36+6周常规超声预测SGA的AUC显著高于31+0至33+6周(P<0.001)。
  • 两个孕周窗口筛查任何时期分娩的SGA,EFW Z评分预测效能均显著优于AC Z评分。
  • 35+0至36+6周EFW<第10百分位预测2周内分娩的出生体重<第10百分位SGA检出率为70%。

核心结论

  • 妊娠晚期常规超声对SGA的预测效能,在35+0至36+6周筛查高于31+0至33+6周,采用EFW优于AC,结局为出生体重<第3百分位优于<第10百分位,分娩在筛查后2周内优于任何时期;EFW<第10百分位预测SGA效能有限,35+0至36+6周检出>85%病例需用EFW<第40百分位。

研究设计与样本

  • 前瞻性研究,纳入21 989例在31+0至33+6周和45 847例在35+0至36+6周接受常规超声的単胎妊娠,用Hadlock公式由头围、AC和股骨长度计算EFW,按胎儿医学基金会胎儿和新生儿人群体重曲线表达为百分位,并以出生体重<第10和第3百分位定义SGA。

诊断标准与关键数值

  • 以EFW<第10百分位在35+0至36+6周筛查,预测筛查后2周内分娩的出生体重<第10和第3百分位SGA的检出率分别为70%和84%,预测任何时期分娩者分别为46%和65%;以EFW<第40百分位筛查,预测2周内分娩的出生体重<第10和第3百分位SGA检出率分别为95%和99%,预测任何时期分娩者分别为87%和94%。

临床应用与阅片要点

  • 阅片时按胎儿医学基金会胎儿和新生儿人群体重曲线将EFW和AC转换为百分位,注意35+0至36+6周EFW Z评分对SGA的预测优于AC Z评分,且EFW<第10百分位预测SGA效能有限。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate and compare the performance of routine ultrasonographic estimated fetal weight (EFW) and fetal abdominal circumference (AC) at 31 + 0 to 33 + 6 and 35 + 0 to 36 + 6 weeks' gestation in the prediction of a small-for-gestational-age (SGA) neonate.

METHODS: This was a prospective study of 21 989 singleton pregnancies undergoing routine ultrasound examination at 31 + 0 to 33 + 6 weeks' gestation and 45 847 undergoing routine ultrasound examination at 35 + 0 to 36 + 6 weeks' gestation. In each case, the estimated fetal weight (EFW) from measurements of fetal head circumference, AC and femur length was calculated using the Hadlock formula and expressed as a percentile according to The Fetal Medicine Foundation fetal and neonatal population weight charts. The same charts were used for defining a SGA neonate with birth weight < 10th and < 3rd percentiles. For each gestational-age window, the screen-positive and detection rates, at different EFW percentile cut-offs between the 10th and 50th percentiles, were calculated for prediction of delivery of a SGA neonate with birth weight < 10th and < 3rd percentiles within 2 weeks and at any stage after assessment. The areas under the receiver-operating characteristics curves (AUC) in screening for a SGA neonate by EFW and AC at 31 + 0 to 33 + 6 and at 35 + 0 to 36 + 6 weeks' gestation were compared.

RESULTS: First, the AUCs in screening by EFW for a SGA neonate with birth weight < 10th and < 3rd percentiles delivered within 2 weeks and at any stage after screening at 35 + 0 to 36 + 6 weeks' gestation were significantly higher than those at 31 + 0 to 33 + 6 weeks (P < 0.001). Second, at both 35 + 0 to 36 + 6 and 31 + 0 to 33 + 6 weeks' gestation, the predictive performance for a SGA neonate with birth weight < 10th and < 3rd percentiles born at any stage after screening was significantly higher using EFW Z-score than AC Z-score. Similarly, at 35 + 0 to 36 + 6 weeks, but not at 31 + 0 to 33 + 6 weeks, the predictive performance for a SGA neonate with birth weight < 10th and < 3rd percentiles born within 2 weeks after screening was significantly higher using EFW Z-score than AC Z-score. Third, screening by EFW < 10th percentile at 35 + 0 to 36 + 6 weeks' gestation predicted 70% and 84% of neonates with birth weight < 10th and < 3rd percentiles, respectively, born within 2 weeks after assessment, and the respective values for a neonate born at any stage after assessment were 46% and 65%. Fourth, prediction of > 85% of SGA neonates with birth weight < 10th percentile born at any stage after screening at 35 + 0 to 36 + 6 weeks' gestation requires use of EFW < 40th percentile. Screening at this percentile cut-off predicted 95% and 99% of neonates with birth weight < 10th and < 3rd percentiles, respectively, born within 2 weeks after assessment, and the respective values for a neonate born at any stage after assessment were 87% and 94%.

CONCLUSIONS: The predictive performance for a SGA neonate of routine ultrasonographic examination during the third trimester is higher if, first, the scan is carried out at 35 + 0 to 36 + 6 weeks' gestation than at 31 + 0 to 33 + 6 weeks, second, the method of screening is EFW than fetal AC, third, the outcome measure is birth weight < 3rd than < 10th percentile, and, fourth, if delivery occurs within 2 weeks than at any stage after assessment. Prediction of a SGA neonate by EFW < 10th percentile is modest and prediction of > 85% of cases at 35 + 0 to 36 + 6 weeks' gestation necessitates use of EFW < 40th percentile. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Ciobanu A, Khan N, Syngelaki A, et al. Routine ultrasound at 32 vs 36 weeks' gestation: prediction of small-for-gestational-age neonates. Ultrasound Obstet Gynecol. 2019. PMID: 30883981. doi:10.1002/uog.20258

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。