应用滤波直方图法评估迭代重建算法对肝实质CT纹理特征的影响
本回顾性研究纳入58例患者(正常肝脏34例、慢性肝病24例),采用同一台CT扫描仪行肝脏CT检查,所有图像分别用滤波反投影、混合迭代重建(iDOSE⁴)和基于模型的迭代重建(IMR)重建。在动脉期和门静脉期于肝门层面行单层感兴趣区定量纹理分析,结果显示迭代重建技术影响肝实质多种CT纹理特征,尤其IMR与FBP或混合迭代重建相比在动脉期和门静脉期均常见显著差异;门静脉期熵在三组重建算法间差异有统计学意义(p < 0.05);正常肝脏与慢性肝病患者的比较显示动脉期图像比门静脉期图像更依赖重建方法;无滤波时观察者间和观察者内ICC均>0.75。
要点
- 重建算法会显著影响肝实质的CT纹理特征,比较纹理数值时需注意所用重建方法。
- 基于模型的迭代重建(IMR)与FBP或混合迭代重建相比,在动脉期和门静脉期常见纹理特征显著差异。
- 门静脉期熵值在三种重建算法间差异有统计学意义(p < 0.05)。
核心结论
- 用滤波直方图法评估的肝实质CT纹理特征受所用CT重建算法的显著影响。
研究设计与样本
- 回顾性研究,纳入58例患者(正常肝脏34例、慢性肝病24例),使用同一台CT扫描仪行肝脏CT检查。
- 所有CT图像分别用滤波反投影(FBP)、混合迭代重建(iDOSE⁴)和基于模型的迭代重建(IMR)重建。
- 在动脉期和门静脉期于肝门层面用单层感兴趣区行定量纹理分析,方法为基于滤波直方图统计、采用不同滤波值。
- 通过计算组内相关系数(ICC)评估CT纹理分析的观察者间和观察者内可靠性。
诊断标准与关键数值
- 无滤波CT图像的观察者间和观察者内ICC均可接受(> 0.75)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma.
MATERIALS AND METHODS: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans using a single CT scanner. All CT images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR) (iDOSE⁴), and model-based IR (IMR). On arterial phase (AP) and portal venous phase (PVP) CT imaging, quantitative texture analysis of the liver parenchyma using a single-slice region of interest was performed at the level of the hepatic hilum using a filtration-histogram statistic-based method with different filter values. Texture features were compared among the three reconstruction methods and between normal livers and those from CLD patients. Additionally, we evaluated the inter- and intra-observer reliability of the CT texture analysis by calculating intraclass correlation coefficients (ICCs).
RESULTS: IR techniques affect various CT texture features of the liver parenchyma. In particular, model-based IR frequently showed significant differences compared to FBP or hybrid IR on both AP and PVP CT imaging. Significant variation in entropy was observed between the three reconstruction algorithms on PVP imaging (p < 0.05). Comparison between normal livers and those from CLD patients revealed that AP images depend more strongly on the reconstruction method used than PVP images. For both inter- and intra-observer reliability, ICCs were acceptable (> 0.75) for CT imaging without filtration.
CONCLUSION: CT texture features of the liver parenchyma evaluated using the filtration-histogram method were significantly affected by the CT reconstruction algorithm used.
引用
- Sung P, Lee JM, Joo I, et al. Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method. Korean J Radiol. 2019. PMID: 30887738. doi:10.3348/kjr.2018.0368
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。