原发性硬化性胆管炎中的磁共振弹性成像:手动与自动方法测量肝脏硬度的观察者间一致性
研究纳入79例连续原发性硬化性胆管炎(PSC)患者,比较3名低年资阅片者与1名MRE专家(11年经验)手动自由画取(fROI)、平均画取(aROI)及自动肝脏弹性计算(ALEC)测量肝硬度的观察者间一致性,以专家fROI为参考标准。结果显示专家与阅片者fROI、aROI及ALEC的ICC分别为0.989、0.971和0.972,fROI表现更优;作者认为PSC肝硬度测量可优先选用fROI。
要点
- PSC患者MRE肝硬度测量中,fROI的观察者间一致性优于aROI和ALEC(ICC 0.989 vs 0.971、0.972)。
- 以专家fROI为参考标准时,fROI和ALEC测得面积ICC为0.64和0.56,aROI面积ICC仅0.12。
- 专家fROI与两名阅片者aROI的肝硬度值存在显著差异,而三名阅片者fROI之间无显著差异。
核心结论
- 在PSC患者中,MRE肝硬度测量采用fROI和aROI均显示极好的观察者间一致性,且fROI表现更优,作者认为PSC肝硬度测量可优先选用fROI。
研究设计与样本
- 研究纳入79例连续PSC患者,均接受肝脏MRI和MRE检查;由3名具有1-3年MRE经验的阅片者和1名MRE专家(11年经验)独立进行肝硬度测量,分别采用手动自由画取(fROI)、平均画取(aROI)及自动肝脏弹性计算(ALEC),以专家fROI为参考标准,行相关分析和绝对组内相关系数(ICC)分析。
诊断标准与关键数值
- 专家与阅片者fROI的ICC为0.989(95%CI 0.985-0.993),aROI的ICC为0.971(95%CI 0.953-0.983),ALEC的ICC为0.972(95%CI 0.957-0.982),fROI表现更优;采用fROI和ALEC测量的面积与专家fROI的ICC分别为0.64和0.56,aROI面积的ICC为0.12。
临床应用与阅片要点
- 作者认为PSC患者MRE肝硬度测量可优先选用fROI;专家fROI与两名阅片者aROI的肝硬度值存在显著差异,而三名阅片者fROI之间无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVE: Primary sclerosing cholangitis, a chronic liver disease causes heterogeneous parenchymal changes and fibrosis. Liver stiffness measurement (LSM) with magnetic resonance Elastography (MRE) may be affected by this heterogeneous distribution. We evaluated interobserver agreement of LSM in primary sclerosing cholangitis (PSC) with manual and automated methods to study the influence of heterogeneous changes.
MATERIALS AND METHODS: A total of 79 consecutive patients with PSC who had a liver MRI and MRE formed the study group. Three readers with 1-3 years' experience in MRE and a MRE expert (11 years' experience) independently performed LSM. Each reader manually drew free hand (fROI) and average (aROI) on stiffness maps. Automatic liver elasticity calculation (ALEC) was used to generate automated LSM. The expert fROI was the reference standard. Correlation analysis and absolute intra-class correlation coefficient (ICC) analysis was performed.
RESULTS: LSM data of 79 livers and 315 sections were evaluated. There was excellent ICC between expert and reader fROIs (0.989, 95% confidence interval, and 0.985-0.993) and aROIs (0.971, 95% confidence interval, and 0.953-0.983) and ALEC (0.972, 0.957-0.982) with fROI performing better. The areas measured with fROIs and ALEC had moderate ICC with Expert fROI (0.64 and 0.56, respectively) whereas aROI area had a poor ICC of 0.12. Comparison of multiple methods showed significant differences in LSM between expert fROI and aROI of two readers and no significant differences for fROIs of all three readers.
CONCLUSION: LSM with MRE in PSC patients shows excellent interobserver agreement with both fROI and aROI methods with better performance with fROI. fROI may therefore be preferred for LSM measurements in PSC.
引用
- Hoodeshenas S, Welle CL, Navin PJ, et al. Magnetic Resonance Elastography in Primary Sclerosing Cholangitis: Interobserver Agreement for Liver Stiffness Measurement with Manual and Automated Methods. Acad Radiol. 2019. PMID: 30878345. doi:10.1016/j.acra.2019.02.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。