文献速递腹部MR

钆塞酸增强MRI中T1 mapping评估肝功能:look-locker反转恢复法与B1不均匀性校正可变翻转角法的比较

T1 mapping for liver function evaluation in gadoxetic acid-enhanced MR imaging: comparison of look-locker inversion recovery and B1 inhomogeneity-corrected variable flip angle method.
PubMed 文献 · Eur Radiol · 2019-03-22

这项回顾性研究纳入248例肝功能正常、慢性肝病或肝硬化患者,在钆塞酸增强MRI的10分钟和20分钟肝胆期用LLIR和B1不均匀性校正VFA两种方法行T1 mapping。结果显示两种方法的T1Liver-post强相关但有显著差异;LLIR 10分钟肝胆期计算的adjusted T1Liver和T1Liver-post可能在评估肝功能和预测肝功能不全及失代偿方面表现最佳。

要点

  • 两种方法的T1Liver-post强相关(r=0.93)但存在显著差异,随访中不可互换使用。
  • LLIR 10分钟肝胆期adjusted T1Liver在显示肝硬化方面表现最高(p<0.025)。
  • 血清白蛋白联合LLIR 10分钟肝胆期adjusted T1Liver或T1Liver-post预测肝功能不全和失代偿表现最佳。

核心结论

  • 两种方法的T1Liver-post强相关但存在显著差异;使用LLIR在10分钟肝胆期获取adjusted T1Liver和T1Liver-post可能是评估肝功能和预测肝功能不全及失代偿的最佳方法。

研究设计与样本

  • 回顾性研究,纳入248例肝功能正常、慢性肝病或肝硬化患者,行钆塞酸增强肝脏MRI,在10分钟和20分钟肝胆期用LLIR和B1不均匀性校正VFA两种方法行T1 mapping。

关键影像表现/征象

  • 两种方法的T1Liver-post强相关(r=0.93,p<0.001)但存在显著差异。
  • LLIR 10分钟肝胆期adjusted T1Liver在显示肝硬化方面表现最高(p<0.025)。

诊断标准与关键数值

  • 显示肝硬化:LLIR 10分钟肝胆期adjusted T1Liver表现最高(p<0.025)。
  • 预测肝功能不全:血清白蛋白联合LLIR 10分钟肝胆期adjusted T1Liver,AIC 58.37,C-index 0.867。
  • 预测失代偿:血清白蛋白联合LLIR 10分钟肝胆期T1Liver-post,AIC 48.82,C-index 0.885。

临床应用与阅片要点

  • LLIR与B1不均匀性校正VFA两种方法测得的T1Liver-post在10分钟和20分钟肝胆期均强相关但存在显著差异,慢性肝病或肝硬化患者随访中不可互换使用。
  • 使用LLIR在10分钟肝胆期获取adjusted T1Liver和T1Liver-post可能是评估整体肝功能和预测临床结局的最适方法和参数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare look-locker inversion recovery (LLIR) and B1 inhomogeneity-corrected variable flip angle T1 mapping methods for estimation of liver function and prediction of hepatic insufficiency and decompensation on gadoxetic acid-enhanced MR imaging.

METHODS: In this retrospective study, 248 patients with normal liver function, chronic liver disease, or cirrhosis underwent gadoxetic acid-enhanced liver MR imaging, including T1 mapping at 10-min and 20-min hepatobiliary phase (HBP) by using both methods. T1 relaxation times of the liver (T1Liver-pre, T1Liver-post) and the spleen (T1Spleen) were correlated between two methods. ΔT1Liver ([T1Liver-pre - T1Liver-post]/T1Liver-pre), adjusted T1Liver ([T1Spleen - T1Liver-post]/T1Spleen), and functional liver volume-to-weight ratio (liver volume on volumetric T1 map/[T1Liver-post × patient's weight]) were calculated. The diagnostic performance of T1 parameters and the predictive performance of models (serum marker, serum marker plus T1 parameter) were compared.

RESULTS: T1Liver-post showed a strong correlation (r = 0.93, p < 0.001) between two methods but was significantly different. For depicting cirrhosis, LLIR-adjusted T1Liver at 10-min HBP showed the highest performance (p < 0.025). For predicting hepatic insufficiency and decompensation, LLIR-adjusted T1Liver (Akaike information criterion (AIC), 58.37; C-index, 0.867) and LLIR-T1Liver-post (AIC, 48.82; C-index, 0.885) at 10-min HBP showed the best performance, respectively, when added to serum albumin level.

CONCLUSIONS: T1Liver-post showed a strong correlation between two methods but with significant differences. T1 mapping using LLIR at 10-min HBP with obtainment of adjusted T1Liver and T1Liver-post may be the best approach for estimation of liver function and prediction of hepatic insufficiency and decompensation.

KEY POINTS: • T1 Liver-post showed a strong correlation between LLIR and B 1 inhomogeneity-corrected VFA methods, both at 10-min and 20-min HBP but with significant differences. • T1 Liver-post at 10-min and 20-min HBP using LLIR and B 1 inhomogeneity-corrected VFA methods could not be used interchangeably during the follow-up in patients with chronic liver disease (CLD) or cirrhosis. • T1 mapping using LLIR at 10-min HBP with obtainment of adjusted T1 Liver and T1 Liver-post may be the most suitable method and parameter for estimation of global liver function and prediction of clinical outcomes in patients with CLD or cirrhosis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim JE, Kim HO, Bae K, et al. T1 mapping for liver function evaluation in gadoxetic acid-enhanced MR imaging: comparison of look-locker inversion recovery and B1 inhomogeneity-corrected variable flip angle method. Eur Radiol. 2019. PMID: 30903328. doi:10.1007/s00330-018-5947-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。