文献速递外周血管介入DSA

数字方差血管造影作为二氧化碳血管造影的范式转变

Digital Variance Angiography as a Paradigm Shift in Carbon Dioxide Angiography.
PubMed 文献 · Invest Radiol · 2019-01-01

该前瞻性研究纳入24例下肢CO2血管造影患者,在2个临床中心比较数字方差血管造影(DVA)与数字减影血管造影(DSA)的信噪比和视觉图像质量,发现DVA的信噪比和图像质量评分均高于DSA,可能有助于CO2作为更安全对比剂的临床应用。

要点

  • DVA在下肢CO2血管造影中产生的信噪比高于DSA,HVC中位比值为3.53,BKCH为4.52。
  • 视觉评价中DVA图像质量优于DSA,HVC为78%的比较、BKCH为90%的比较。
  • DVA图像个体评分在HVC为3.23±0.16 vs DSA 2.75±0.12(P<0.05),BKCH为3.03±0.09 vs 2.49±0.10(P<0.001)。

核心结论

  • 下肢CO2血管造影中,无论图像采集设备和协议如何,DVA均产生比DSA更高的信噪比和显著更好的图像质量,因此这种新图像处理技术可能有助于CO2作为更安全对比剂在临床实践中的广泛使用。

研究设计与样本

  • 前瞻性研究,纳入24例接受下肢CO2血管造影的患者(平均年龄65.5±9.2岁;男性14例,65.1±7.5岁;女性10例,66.1±11.6岁),于2017年12月至2018年4月在2个临床中心入组:布达佩斯Semmelweis大学心脏与血管中心(HVC,7例)和凯奇凯梅特Bács-Kiskun县医院(BKCH,17例);两中心介入方案相似但图像采集设备和协议不同。

诊断标准与关键数值

  • 在110对图像中选取4912个感兴趣区计算SNR;HVC的SNRDVA/SNRDSA在解剖区域(腹部、髂、股、腘、小腿、距骨)范围为2.58至4.16,总体中位值3.53;BKCH范围为2.71至4.92,总体中位值4.52;视觉评价比较120对DSA和DVA图像,HVC中78%的比较判定DVA图像质量更高,BKCH中90%的比较高;评价者间一致性HVC为88%(P<0.001),BKCH为90%(P<0.01);5级评分(1分差至5分优)中,HVC总体DSA和DVA评分分别为2.75±0.12和3.23±0.16(P<0.05),BKCH分别为2.49±0.10和3.03±0.09(P<0.001)。

临床应用与阅片要点

  • 原文结论指出DVA可能有助于CO2作为更安全对比剂在临床实践中的广泛使用。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Our aim was to investigate the feasibility of digital variance angiography (DVA) in lower extremity CO2 angiography and to compare the quantitative and qualitative performance of the new image processing technique with that of the current reference standard digital subtraction angiography (DSA).

MATERIALS AND METHODS: This prospective study enrolled 24 patients (mean age ± SD, 65.5 ± 9.2 years; 14 males, 65.1 ± 7.5 years; 10 females, 66.1 ± 11.6 years) undergoing lower-limb CO2 angiography between December 2017 and April 2018 at 2 clinical centers: The Heart and Vascular Center (HVC) of Semmelweis University, Budapest (7 patients), and the Bács-Kiskun County Hospital (BKCH) in Kecskemét (17 patients). The interventional protocol was similar at both sites, but the image acquisition instruments and protocols were different, which allowed us to investigate DVA in different settings. For comparison, the signal-to-noise ratio (SNR) of DSA and DVA images were calculated. The visual quality of DSA and DVA images were compared by independent clinical specialists using an online questionnaire. Interrater agreement was characterized by percent agreement and Fleiss kappa. The specialists also evaluated in a random and blinded manner the individual DSA and DVA images on a 5-grade scale ranging from poor (1) to outstanding (5) image quality, and the mean ± standard error of mean (SEM) was calculated.

RESULTS: A total of 4912 regions of interest were carefully selected in 110 image pairs to determine the SNRs. The ratio of SNRDVA/SNRDSA was calculated. At HVC, it ranged between 2.58 and 4.16 in the anatomical regions (abdominal, iliac, femoral, popliteal, crural, talar), and the overall median value was 3.53, whereas at BKCH the range was 2.71 to 4.92 and the overall median value was 4.52. During the visual evaluation, 120 DSA and DVA image pairs were compared. At HVC in 78%, although at BKCH in 90% of comparisons, it was judged that DVA provided higher quality images. The interrater agreement was 88% (P < 0.001) and 90% (P < 0.01), respectively. DVA images received consistently higher individual rating than DSA images, regardless of the research site and anatomical region. At HVC, the overall DSA and DVA scores (mean ± SEM) were 2.75 ± 0.12 and 3.23 ± 0.16, respectively (P < 0.05), whereas at BKCH these values were 2.49 ± 0.10 and 3.03 ± 0.09, respectively (P < 0.001).

CONCLUSIONS: These data show that lower-limb CO2 angiography DVA, regardless of the image acquisition instruments and protocols, produces higher SNR and significantly better image quality than DSA; therefore this new image processing technique might help the widespread use of CO2 as a safer contrast agent in clinical practice.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Óriás VI, Gyánó M, Góg I, et al. Digital Variance Angiography as a Paradigm Shift in Carbon Dioxide Angiography. Invest Radiol. 2019. PMID: 30829769. doi:10.1097/RLI.0000000000000555

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。