文献速递儿科影像泌尿生殖腹部USCT

儿童肾结石超声声影:以非增强计算机断层扫描为参考标准的回顾性研究

Acoustic shadowing in pediatric kidney stone ultrasound: a retrospective study with non-enhanced computed tomography as reference standard.
PubMed 文献 · Pediatr Radiol · 2019-03-14

回顾性纳入2015至2016年一家儿童肾结石转诊中心因肾结石行腹部非增强CT的31例患儿(77枚可疑结石),对照CT评估超声声影、闪烁伪影及结石大小。声影诊断敏感度70%、特异度100%,但特异度未达统计学显著;闪烁伪影敏感度88%,但因缺乏真阴性无法计算特异度,且假阳性结石均显示闪烁伪影、无声影。

要点

  • 儿童肾结石超声声影敏感度70%、特异度100%,但特异度置信区间宽(56-100%)未达显著。
  • 直径≥9 mm的肾结石均出现声影,小结石声影可能不明显。
  • 闪烁伪影敏感度高(88%)但假阳性结石均显示闪烁伪影,需警惕假阳性。

核心结论

  • 多数儿童肾结石超声可见声影,声影特异度高但未达统计学显著;闪烁伪影是检测儿童肾结石的敏感超声工具,但存在假阳性风险。

研究设计与样本

  • 回顾性观察研究,纳入2015至2016年一家儿童肾结石转诊中心因肾结石行腹部非增强CT的儿童,共31例患者(中位年龄13岁,范围1-17岁)、77枚可疑肾结石,以CT为参考标准回顾性评估超声特征。

关键影像表现/征象

  • 超声评估的结石特征包括声影、闪烁伪影和结石大小。
  • 所有超声假阳性结石均显示闪烁伪影,但均未显示声影。
  • 直径≥9 mm的肾结石均出现声影。

诊断标准与关键数值

  • 声影诊断儿童肾结石的敏感度70%(95%CI 56-80%),特异度100%(95%CI 56-100%)。
  • 闪烁伪影诊断儿童肾结石的敏感度88%(95%CI 72-96%),特异度因缺乏真阴性无法计算。
  • 结石中位大小5 mm(四分位距5 mm)。

临床应用与阅片要点

  • 超声发现儿童肾结石闪烁伪影时需注意假阳性可能,声影出现支持结石诊断。
  • 直径≥9 mm的结石超声均可见声影,较小结石声影可能不明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The usefulness of acoustic shadowing as a feature of pediatric kidney stone ultrasound (US) may be underestimated.

OBJECTIVE: The hypothesis was that the majority of stones in children have acoustic shadowing and that its specificity is high (>90%) in pediatric kidney stones.

MATERIALS AND METHODS: Our retrospective observational study included children who had undergone abdominal non-enhanced computed tomography (CT) for kidney stones in a pediatric renal stone referral centre between 2015 and 2016. US examinations prior to CT were retrospectively assessed for US features such as acoustic shadowing, twinkle artifact and stone size. These features were compared to CT as reference standard.

RESULTS: Thirty-one patients (median age: 13 years, range: 1-17 years) with 77 suspected kidney stones were included. The median stone size was 5 mm (interquartile range [IQR]: 5 mm). For acoustic shadowing, sensitivity was 70% (95% confidence interval [CI] 56-80%) and specificity was 100% (95% CI 56-100%). All kidney stones with a diameter ≥9 mm demonstrated shadowing. Sensitivity for twinkle artifact was 88% (95% CI 72-96%), but specificity for twinkle artifact could not be calculated due to the lack of true negatives. All false-positive stones on US demonstrated twinkle artifact, but none showed shadowing.

CONCLUSION: Acoustic shadowing was demonstrated in the majority of pediatric kidney stones. Specificity was high, but this was not significant. Twinkle artifact is a sensitive US tool for detecting (pediatric) kidney calculi, but with a risk of false-positive findings.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Verhagen MV, Watson TA, Hickson M, et al. Acoustic shadowing in pediatric kidney stone ultrasound: a retrospective study with non-enhanced computed tomography as reference standard. Pediatr Radiol. 2019. PMID: 30868197. doi:10.1007/s00247-019-04372-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。