文献速递外周血管心血管CT

双感兴趣区定时团注技术以9秒对比剂注射时长行主动脉CT血管成像

Double ROI Timing Bolus Technique to Perform Aortic CT Angiography With a 9-Second Contrast Injection Duration.
PubMed 文献 · AJR Am J Roentgenol · 2019-03-27

前瞻性研究纳入106例需评估主动脉瘤、夹层或疑似主动脉疾病的患者,采用双感兴趣区定时团注技术,以40 mL对比剂在9秒内完成主动脉CTA。与传统方法相比,该技术显著减少对比剂用量(40.0 mL vs 88.0 ± 9.4 mL),提高主动脉强化(403.3 ± 76.0 HU vs 359.7 ± 61.5 HU),降低上腔静脉强化(118.9 ± 46.2 HU vs 239.2 ± 130.5 HU),并在有既往CTA图像的患者中降低有效剂量(8.3 ± 1.7 mSv vs 12.4 ± 3.2 mSv)。

要点

  • 双ROI定时团注技术用40 mL对比剂9秒注射完成主动脉CTA,较传统方法88.0±9.4 mL显著减少用量。
  • 该技术主动脉强化403.3±76.0 HU,高于传统方法359.7±61.5 HU;上腔静脉强化118.9±46.2 HU,低于传统方法239.2±130.5 HU。
  • 有既往CTA图像的患者中,该技术有效剂量8.3±1.7 mSv,低于传统方法12.4±3.2 mSv。

核心结论

  • 双ROI定时团注法行主动脉CTA可大幅减少对比剂用量,同时提高主动脉强化并降低辐射剂量。

研究设计与样本

  • 前瞻性研究,2018年2月至7月纳入106例有主动脉瘤、夹层或疑似主动脉疾病临床指征的患者,其中47例有既往传统方法主动脉CTA图像;双ROI定时团注技术根据定时团注数据获得的升主动脉和降主动脉时间-衰减曲线计算扫描速度以同步主动脉血流;传统扫描以1.7 mL/kg体重注射对比剂25秒;测量主动脉髂动脉6个点和上腔静脉的强化,采用t检验比较。

关键影像表现/征象

  • 双ROI定时团注法主动脉髂动脉强化403.3±76.0 HU,传统方法359.7±61.5 HU(p<0.001)。
  • 双ROI定时团注法上腔静脉强化118.9±46.2 HU,传统方法239.2±130.5 HU(p<0.001)。

诊断标准与关键数值

  • 双ROI定时团注法对比剂用量40.0 mL,传统方法88.0±9.4 mL(p<0.001)。
  • 有既往CTA图像的患者中,双ROI定时团注法有效剂量8.3±1.7 mSv,传统方法12.4±3.2 mSv(p<0.01)。

临床应用与阅片要点

  • 双ROI定时团注技术可用于主动脉CTA,以40 mL对比剂9秒注射完成扫描。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to investigate the feasibility of a double ROI timing bolus technique for performing aortic CT angiography (CTA) with 40 mL of contrast medium over 9 seconds. SUBJECTS AND METHODS. A prospective study from February to July 2018 included 106 patients with clinical indications for evaluation of aortic aneurysm or dissection or suspected aortic disease. Forty-seven of these patients had undergone prior aortic CTA by the conventional method. The scanning speed for the double ROI timing bolus technique was calculated from the time-attenuation curves of the ascending and descending aorta by use of the timing bolus data to synchronize aortic flow. The conventional scan was obtained by injection of 1.7 mL of contrast medium per kilogram of body weight for 25 seconds. Enhancement of six points on the aortoiliac arteries and superior vena cava was measured. The t test was used to compare the values. RESULTS. Use of the double ROI timing bolus method significantly reduced the amount of contrast medium injected compared with the amount for the conventional method (40.0 mL vs 88.0 ± 9.4 mL, p < 0.001). Use of the method significantly increased aortoiliac enhancement (403.3 ± 76.0 HU vs 359.7 ± 61.5 HU, p < 0.001) and significantly decreased enhancement of the superior vena cava (118.9 ± 46.2 HU vs 239.2 ± 130.5 HU, p < 0.001) compared with the conventional method. In the group with prior CTA images available, the effective dose was significantly lower with the double ROI timing bolus than with the conventional method (8.3 ± 1.7 mSv vs 12.4 ± 3.2 mSv, p < 0.01). CONCLUSION. Use of the double ROI timing bolus method can dramatically reduce the amount of contrast medium used during aortic CTA while improving aortic enhancement and reducing radiation dose.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Tomizawa N, Ito S, Nakao T, et al. Double ROI Timing Bolus Technique to Perform Aortic CT Angiography With a 9-Second Contrast Injection Duration. AJR Am J Roentgenol. 2019. PMID: 30917025. doi:10.2214/AJR.18.20766

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。