文献速递心血管CT

自由呼吸触发的新团注跟踪法提高冠状动脉CT血管成像的强化程度与均匀性

Improving the Degree and Uniformity of Enhancement in Coronary CT Angiography with a New Bolus Tracking Method Enabled By Free Breathing.
PubMed 文献 · Acad Radiol · 2019-03-04

本研究将200例疑似冠心病患者随机分为自由呼吸组(n=100,主动脉衰减达250 HU后延迟2.2秒触发)与屏气组(n=100,采用80 HU阈值、延迟8.4秒的标准方案)行冠状动脉CT血管成像。自由呼吸组血管平均强化程度高于屏气组(404±66 HU vs 321±69 HU),且各冠状动脉的CT值变异系数更低(均p<0.05),而对比剂剂量、辐射剂量、心率及定性图像质量两组无差异。

要点

  • 自由呼吸触发方案在16 cm宽体CT上行CCTA,血管平均强化程度高于常规屏气方案。
  • 自由呼吸组各冠状动脉CT值变异系数均低于屏气组,强化均匀性更好。
  • 两组对比剂剂量、辐射剂量、心率及定性图像质量无差异。

核心结论

  • 在16 cm宽体CT系统上行CCTA时,自由呼吸触发的新团注跟踪法较常规屏气法提高了冠状动脉的强化程度与均匀性。

研究设计与样本

  • 随机对照研究,共纳入200例疑似冠心病患者,分为自由呼吸组(A组,n=100)与屏气组(B组,n=100),均使用16 cm宽体CT行CCTA;两组对比剂剂量率均为25 mgI/kg/s。

诊断标准与关键数值

  • A组于主动脉衰减达250 HU后延迟2.2秒启动CCTA;B组采用80 HU阈值、延迟8.4秒的标准方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To demonstrate the improved enhancement degree and uniformity in coronary CT angiography (CCTA) on a 16 cm wide-coverage CT with a new bolus tracking method enabled by free-breathing, in comparison with the conventional breath-holding method.

MATERIALS AND METHODS: A total of 200 patients with suspected coronary heart disease were randomly divided into two groups for CCTA: Group A (n = 100, free-breathing) started CCTA with 2.2 seconds delay after the attenuation in aorta reached 250 HU; Group B (n = 100, breath-holding), used the standard protocol of 80 HU threshold and 8.4 seconds delay. Both groups used the contrast dose rate of 25 mgI/kg/s. CT value and standard deviation in aortic sinus (AS), right coronary artery, left anterior descending, left circumflex, and pericardial fat were measured. Contrast-to-noise ratio for vessels was calculated. Two experienced Radiologists independently reviewed image quality using a 5-point scale (1: nondiagnostic-5: excellent).

RESULTS: There was no difference in contrast dose, radiation dose, heart rate, and qualitative image quality between the two groups (all p > 0.05). However, Group A had higher mean enhancement in vessels (404 ± 66 HU) than Group B (321 ± 69 HU), and lower coefficients of variation of CT value in aortic sinus, right coronary artery, left anterior descending, and left circumflex (16.3%, 17.7%, 19.2%, and 20.5% vs 21.5%, 22.3%, 23.6%, and 22.9%, respectively), (all p < 0.05).

CONCLUSION: A new bolus tracking method enabled by free-breathing in CCTA on a 16 cm wide-coverage CT system increases the enhancement degree and uniformity in coronary arteries, compared with the conventional breath-holding method.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Cao L, Liu X, Li J, et al. Improving the Degree and Uniformity of Enhancement in Coronary CT Angiography with a New Bolus Tracking Method Enabled By Free Breathing. Acad Radiol. 2019. PMID: 30846313. doi:10.1016/j.acra.2019.01.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。