文献速递胸部技术与安全CT

英国先进放疗网络(ART-NET)肺部立体定向消融放疗调查:全国配置情况与影像引导聚焦

The advanced radiotherapy network (ART-NET) UK lung stereotactic ablative radiotherapy survey: national provision and a focus on image guidance.
PubMed 文献 · Br J Radiol · 2019-04-24

该调查向英国62个国民保健署中心发放半结构化在线问卷,评估肺部立体定向消融放疗(SABR)的开展情况与影像引导放疗(IGRT)流程。结果显示36个中心(58%)开展肺部SABR,其中半数年治疗患者少于50例,IGRT使用方式差异很大,近半数开展中心认为需要更新国家影像引导规范。

要点

  • 36个中心(58%)开展肺部SABR,其中一半年治疗患者少于50例。
  • 锥形束CT在工作流程中有8种不同排列顺序,IGRT使用差异大。
  • 17/36个开展中心(47%)认为需要更新肺部SABR的国家影像引导规范。

核心结论

  • 调查显示英国肺部SABR的IGRT流程差异很大,存在优化现有IGRT工作流程和影像引导最佳方法的机会,需进一步研究肺部SABR的配置及实施障碍。

研究设计与样本

  • 在线半结构化调查,最多含32个问题,聚焦治疗影像验证流程,经试点后发放至英国62个国民保健署中心的放疗管理者,完整应答率为100%。

临床应用与阅片要点

  • 原文报告锥形束CT在工作流程中有8种不同排列顺序,并提及「第零天」、治疗中和治疗后锥形束CT的使用。
  • 17/36个开展中心(47%)认为需要更新与肺部SABR相关的国家影像引导规范。
  • 6个中心在未获国民保健署委托提供该服务的情况下仍开展SABR。

局限性

  • 需进一步研究肺部SABR的配置及实施障碍。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Stereotactic ablative radiotherapy (SABR) has become the standard of care for suitable patients with peripherally located early stage non-small cell lung cancer. Lung SABR requires strict image-guided radiotherapy (IGRT) protocols to ensure its safe delivery. The aim of this survey was to provide an assessment of current lung SABR practice in the UK.

METHODS: An online semi-structured survey containing a maximum of 32 questions regarding lung SABR, focussing on treatment image verification processes was piloted, developed and disseminated to the radiotherapy managers of 62 National Health Service centres across the UK.

RESULTS: The survey had a 100% complete response from NHS centres. 36 centres (58%) currently deliver lung SABR, with half treating fewer than 50 patients per year. Six centres deliver SABR despite not being commissioned by the NHS to provide this service. There is wide variation in the use of IGRT. Eight different permutations of cone beam CT order within the workflow were reported. Almost half of lung centres (17/36, 47%) believe there is a need to update national image guidance associated with lung SABR, such as the use of 'day zero', mid treatment and post treatment cone beam CTs.

CONCLUSION: Our results demonstrate wide variation in IGRT for lung SABR. There is an opportunity to develop existing IGRT workflows and the optimal approach to image guidance. Further work is required to investigate lung SABR provision and potential barriers to its implementation.

ADVANCES IN KNOWLEDGE: This survey represents the most comprehensive and accurate assessment of lung SABR practice in the UK since the 2014 SABR consortium survey.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Beasley M, Brown S, McNair H, et al. The advanced radiotherapy network (ART-NET) UK lung stereotactic ablative radiotherapy survey: national provision and a focus on image guidance. Br J Radiol. 2019. PMID: 30924682. doi:10.1259/bjr.20180988

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。