文献速递外周血管胸部介入DSA

评估一种新开发的二维参数化肺实质血流技术结合自动血管抑制算法在慢性血栓栓塞性肺动脉高压患者球囊肺动脉成形术中的应用

Evaluation of a newly developed 2D parametric parenchymal blood flow technique with an automated vessel suppression algorithm in patients with chronic thromboembolic pulmonary hypertension undergoing balloon pulmonary angioplasty.
PubMed 文献 · Clin Radiol · 2019-03-16

研究纳入18例慢性血栓栓塞性肺动脉高压患者共35次球囊肺动脉成形术(BPA)干预、98条治疗肺动脉,用二维参数化肺实质血流(2D-PPBF)对DSA序列后处理定量肺实质灌注变化;BPA后肺血流分级评分从1改善至3(p<0.0001),HPD、AP、MTT比值下降而WIR、AUC比值升高,各参数变化与血流分级评分变化相关。结论认为2D-PPBF技术可行,有潜力改善BPA监测。

要点

  • BPA后肺血流分级评分由1改善至3(p<0.0001),2D-PPBF参数变化与评分变化相关。
  • WIR比值变化与血流分级评分变化相关性最强(ρ=0.43,p<0.0001),AUC比值次之(ρ=0.48,p<0.0001)。
  • 2D-PPBF通过DSA序列后处理定量肺实质灌注,作者认为该技术可行并有潜力改善BPA监测。

核心结论

  • 2D-PPBF技术用于定量BPA后肺实质灌注变化是可行的,并具有改善BPA监测的潜力。

研究设计与样本

  • 研究纳入18例慢性血栓栓塞性肺动脉高压患者共35次连续BPA干预、98条治疗肺动脉,对BPA前后采集的DSA序列用专用软件行2D-PPBF后处理,在治疗肺动脉放置参考ROI(动脉流入)并在目标狭窄远端全部肺实质放置远端目标ROI,计算两者比值并与肺血流分级评分变化做相关分析。

诊断标准与关键数值

  • BPA后肺血流分级评分由1改善至3(p<0.0001);HPDparenchyma/HPDinflow变化-10.2%(p<0.0001)、APparenchyma/APinflow变化-24.4%(p=0.0007)、MTTparenchyma/MTTinflow变化-3.5%(p=0.0449)均显著下降,WIRparenchyma/WIRinflow变化+82.4%、AUCparenchyma/AUCinflow变化+58.6%(p<0.0001)显著升高。

临床应用与阅片要点

  • 2D-PPBF参数变化与肺血流分级评分变化相关:HPDparenchyma/HPDinflow(ρ=-0.21,p=0.04)、WIRparenchyma/WIRinflow(ρ=0.43,p<0.0001)、APparenchyma/APinflow(ρ=-0.22,p=0.03)、AUCparenchyma/AUCinflow(ρ=0.48,p<0.0001)、MTTparenchyma/MTTinflow(ρ=-0.39,p<0.0001);作者认为该技术可行并有潜力改善BPA监测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the feasibility of two-dimensional parametric parenchymal blood flow (2D-PPBF) to quantify perfusion changes in the lung parenchyma following balloon pulmonary angioplasty (BPA) for treatment of chronic thromboembolic pulmonary hypertension.

MATERIALS AND METHODS: Overall, 35 consecutive interventions in 18 patients with 98 treated pulmonary arteries were included. To quantify changes in pulmonary blood flow using 2D-PPBF, the acquired digital subtraction angiography (DSA) series were post-processed using dedicated software. A reference region of interest (ROI; arterial inflow) in the treated pulmonary artery and a distal target ROI, including the whole lung parenchyma distal to the targeted stenosis, were placed in corresponding areas on DSA pre- and post-BPA. Half-peak density (HPD), wash-in rate (WIR), arrival to peak (AP), area under the curve (AUC), and mean transit time (MTT) were assessed. The ratios of the reference ROI to the target ROI (HPDparenchyma/HPDinflow, WIRparenchyma/WIRinflow; APparenchyma/APinflow, AUCparenchyma/AUCinflow, MTTparenchyma/MTTinflow) were calculated. The relative differences of the 2D-PPBF parameters were correlated to changes in the pulmonary flow grade score.

RESULTS: The pulmonary flow grade score improved significantly after BPA (1 versus 3; p<0.0001). Likewise, the mean HPDparenchyma/HPDinflow (-10.2%; p<0.0001), APparenchyma/APinflow (-24.4%; p=0.0007), and MTTparenchyma/MTTinflow (-3.5%; p=0.0449) decreased significantly, whereas WIRparenchyma/WIRinflow (+82.4%) and AUCparenchyma/AUCinflow (+58.6%) showed a significant increase (p<0.0001). Furthermore, a significant correlation between changes of the pulmonary flow grade score and changes of HPDparenchyma/HPDinflow (ρ=-0.21, p=0.04), WIRparenchyma/WIRinflow (ρ=0.43, p<0.0001), APparenchyma/APinflow (ρ=-0.22, p=0.03), AUCparenchyma/AUCinflow (ρ=0.48, p<0.0001), and MTTparenchyma/MTTinflow (ρ=-0.39, p<0.0001) could be observed.

CONCLUSION: The 2D-PPBF technique is feasible for the quantification of perfusion changes following BPA and has the potential to improve monitoring of BPA.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Maschke SK, Winther HMB, Meine T, et al. Evaluation of a newly developed 2D parametric parenchymal blood flow technique with an automated vessel suppression algorithm in patients with chronic thromboembolic pulmonary hypertension undergoing balloon pulmonary angioplasty. Clin Radiol. 2019. PMID: 30890260. doi:10.1016/j.crad.2018.12.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。