弹性配准在肺MRI中用于评估系统性硬化症患者肺纤维化的应用
这项前瞻性研究于2017年9月至2018年3月纳入16例系统性硬化症患者(其中7例高分辨率CT示肺纤维化)和11名健康志愿者,采用3.0T设备行吸气末与呼气末超短回波时间梯度回波MRI并作弹性配准,以Jacobian行列式对数小于-0.15的显著收缩区相似度诊断纤维化,敏感度86%、特异度75%(AUC 0.81,P=0.04),Dice相似系数阈值为0.36。
要点
- 吸气至呼气弹性配准可显示肺底呼吸形变,纤维化者肺底形变减弱。
- Jacobian行列式对数小于-0.15的显著收缩区在健康志愿者和无纤维化患者肺底后部可见,纤维化者未见。
- 以Dice相似系数0.36为阈值诊断高分辨率CT所示纤维化,敏感度86%、特异度75%、AUC 0.81(P=0.04)。
核心结论
- 与无纤维化者相比,系统性硬化症相关肺纤维化患者的吸气至呼气MRI显示肺底呼吸形变减弱。
研究设计与样本
- 前瞻性研究,2017年9月至2018年3月招募健康志愿者及近3个月内行胸部高分辨率CT的系统性硬化症患者。
- 共评估16例系统性硬化症患者(其中7例高分辨率CT示肺纤维化)和11名健康志愿者。
- 使用3.0T设备采集深吸气末与呼气末屏气冠状三维超短回波时间梯度回波序列,并以弹性配准算法将吸气像配准至呼气像。
- 由形变场计算Jacobian行列式并以彩色图显示,比较高分辨率CT所示纤维化与无纤维化者及健康志愿者间显著收缩区相似度。
- 以受试者工作特征曲线分析确定诊断纤维化的最佳Dice相似系数阈值。
关键影像表现/征象
- Jacobian行列式对数小于-0.15的显著收缩区见于健康志愿者及无纤维化的系统性硬化症患者肺底后部,纤维化患者未见。
诊断标准与关键数值
- 以Dice相似系数0.36为阈值,MRI诊断高分辨率CT所示纤维化的敏感度86%、特异度75%、AUC 0.81(P=0.04)。
- 以Jacobian行列式对数小于-0.15定义显著收缩区用于比较。
临床应用与阅片要点
- 弹性配准的吸气至呼气肺MRI可用于观察肺底呼吸形变减弱,辅助评估系统性硬化症相关肺纤维化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Current imaging methods are not sensitive to changes in pulmonary function resulting from fibrosis. MRI with ultrashort echo time can be used to image the lung parenchyma and lung motion. Purpose To evaluate elastic registration of inspiratory-to-expiratory lung MRI for the assessment of pulmonary fibrosis in study participants with systemic sclerosis (SSc). Materials and Methods This prospective study was performed from September 2017 to March 2018 and recruited healthy volunteers and participants with SSc and high-resolution CT (within the previous 3 months) of the chest for lung MRI. Two breath-hold, coronal, three-dimensional, ultrashort-echo-time, gradient-echo sequences of the lungs were acquired after full inspiration and expiration with a 3.0-T unit. Images were registered from inspiration to expiration by using an elastic registration algorithm. Jacobian determinants were calculated from deformation fields and represented on color maps. Similarity between areas with marked shrinkage and logarithm of Jacobian determinants less than -0.15 were compared between healthy volunteers and study participants with SSc. Receiver operating characteristic curve analysis was performed to determine the best Dice similarity coefficient threshold for diagnosis of fibrosis. Results Sixteen participants with SSc (seven with pulmonary fibrosis at high-resolution CT) and 11 healthy volunteers were evaluated. Areas of marked shrinkage during expiration with logarithm of Jacobian determinants less than -0.15 were found in the posterior lung bases of healthy volunteers and in participants with SSc without fibrosis, but not in participants with fibrosis. The sensitivity and specificity of MRI for presence of fibrosis at high-resolution CT were 86% and 75%, respectively (area under the curve, 0.81; P = .04) by using a threshold of 0.36 for Dice similarity coefficient. Conclusion Elastic registration of inspiratory-to-expiratory MRI shows less lung base respiratory deformation in study participants with systemic sclerosis-related pulmonary fibrosis compared with participants without fibrosis. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Biederer in this issue.
引用
- Chassagnon G, Martin C, Marini R, et al. Use of Elastic Registration in Pulmonary MRI for the Assessment of Pulmonary Fibrosis in Patients with Systemic Sclerosis. Radiology. 2019. PMID: 30835186. doi:10.1148/radiol.2019182099
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。