基于知识迭代模型重建的超低剂量CT评估肺结核:辐射剂量与图像质量比较
前瞻性纳入59例已知或疑似肺结核患者,先后行自动管电流调制低剂量CT和固定管电流超低剂量CT,原始数据分别用FBP、iDose和IMR重建。IMR在两种剂量水平下噪声更低、CNR更高,超低剂量CT加IMR对结节、实变、树芽征和空洞的主观评分优于低剂量CT加iDose,但可见边缘模糊;平均有效剂量由低剂量CT的0.69±0.15 mSv降至超低剂量CT的0.28±0.02 mSv,降低59%。
要点
- 超低剂量CT加IMR对肺结核征象的主观评分优于低剂量CT加iDose,但存在边缘模糊。
- IMR在两种剂量水平下噪声均低于FBP和iDose,CNR均更高(p<0.01)。
- 超低剂量CT平均有效剂量0.28±0.02 mSv,较低剂量CT的0.69±0.15 mSv降低59%(p<0.001)。
核心结论
- IMR可为接受胸部超低剂量CT的肺结核患者提供显著噪声降低和图像质量提升,有效剂量为0.28 mSv。
研究设计与样本
- 经IRB批准的前瞻性研究,连续纳入59例已知或疑似肺结核患者(平均年龄43.9±16.6岁,女:男18:41),先行自动管电流调制低剂量CT、再行固定管电流超低剂量CT,原始数据分别以FBP、iDose和IMR重建。
关键影像表现/征象
- IMR图像上小叶中心结节、实变、树芽征和空洞的主观评分显著优于低剂量CT加iDose图像(p<0.01),但可见边缘模糊。
诊断标准与关键数值
- IMR在两种剂量水平下噪声显著低于FBP和iDose、CNR显著更高(p<0.01)。
- 超低剂量CT加IMR对上述病理征象的主观评分显著优于低剂量CT加iDose(p<0.01)。
- 超低剂量CT平均有效剂量0.28±0.02 mSv,低剂量CT为0.69±0.15 mSv,超低剂量CT降低59%(p<0.001)。
临床应用与阅片要点
- 对需反复随访CT的肺结核患者,超低剂量CT加IMR可在0.28 mSv有效剂量下显示小叶中心结节、实变、树芽征和空洞,但需注意边缘模糊。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the image quality of ultralow-dose computed tomography (ULDCT) reconstructed with knowledge-based iterative model reconstruction (IMR) in patients with pulmonary tuberculosis (TB).
METHODS: This IRB-approved prospective study enrolled 59 consecutive patients (mean age, 43.9 ± 16.6 years; F:M 18:41) with known or suspected pulmonary TB. Patients underwent a low-dose CT (LDCT) using automatic tube current modulation followed by an ULDCT using fixed tube current. Raw image data were reconstructed with filtered-back projection (FBP), hybrid iterative reconstruction (iDose), and IMR. Objective measurements including CT attenuation, image noise, and contrast-to-noise ratio (CNR) were assessed and compared using repeated-measures analysis of variance. Overall image quality and visualization of normal and pathological findings were subjectively scored on a five-point scale. Radiation output and subjective scores were compared by the paired Student t test and Wilcoxon signed-rank test, respectively.
RESULTS: Compared with FBP and iDose, IMR yielded significantly lower noise and higher CNR values at both dose levels (p < 0.01). Subjective ratings for pathological findings including centrilobular nodules, consolidation, tree-in-bud, and cavity were significantly better with ULDCT IMR images than those with LDCT iDose images (p < 0.01), but blurred edges were observed. With IMR implementation, a 59% reduction of the mean effective dose was achieved with ULDCT (0.28 ± 0.02 mSv) compared with LDCT (0.69 ± 0.15 mSv) without impairing image quality (p < 0.001).
CONCLUSIONS: IMR offers considerable noise reduction and improvement in image quality for patients with pulmonary TB undergoing chest ULDCT at an effective dose of 0.28 mSv.
KEY POINTS: • Radiation dose is a major concern for tuberculosis patients requiring repeated follow-up CT. • IMR allows substantial radiation dose reduction in chest CT without compromising image quality. • ULDCT reconstructed with IMR allows accurate depiction of CT features of pulmonary tuberculosis.
引用
- Yan C, Liang C, Xu J, et al. Ultralow-dose CT with knowledge-based iterative model reconstruction (IMR) in evaluation of pulmonary tuberculosis: comparison of radiation dose and image quality. Eur Radiol. 2019. PMID: 30927099. doi:10.1007/s00330-019-06129-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。