本研究回顾性评估卷积神经网络模型在经皮肺穿刺活检后胸片上检测气胸的诊断性能。模型训练使用1596张含气胸的胸片,独立测试集为2016年1319例患者1333个肺部病灶活检后的随访胸片。模型在3小时随访胸片的敏感度、特异度、AUC分别为61.1%、93.0%、0.898,在1天随访分别为63.4%、93.5%、0.905,并检出全部23例需引流的气胸。

要点

  • CNN模型在PTNB后胸片上检测气胸的AUC达0.898(3小时)与0.905(1天)。
  • 模型特异度高(93.0%-93.5%),阴性预测价值高,但敏感度约61%-63%。
  • 模型检出全部23例需引流气胸,可作为放射科医师判读前的筛查工具。

核心结论

  • CNN模型在PTNB后胸片气胸检测中表现良好,尤其对需进一步处理的气胸,可作为放射科医师判读前的筛查工具。

研究设计与样本

  • 回顾性研究,采用26层YOLO模型构建CNN系统,训练集为1596张含气胸胸片,独立测试集为2016年1319例患者1333个肺部病灶PTNB后的随访胸片,由两名经验丰富的放射科医师共识判定气胸。

诊断标准与关键数值

  • 3小时随访胸片:气胸发生率17.9%(247/1379),敏感度61.1%(151/247),特异度93.0%(1053/1132),AUC 0.898,总体准确率87.3%(1204/1379)。
  • 1天随访胸片:气胸发生率23.3%(309/1329),敏感度63.4%(196/309),特异度93.5%(954/1020),AUC 0.905,总体准确率86.5%(1150/1329)。
  • 全部经皮肺穿刺活检中1.7%(23例)需置入引流管,CNN模型检出全部23例需引流气胸。

临床应用与阅片要点

  • 作者认为CNN模型可作为放射科医师判读前的筛查工具。
  • 模型特异度高、阴性预测价值高,但敏感度约61%-63%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To retrospectively evaluate the diagnostic performance of a convolutional neural network (CNN) model in detecting pneumothorax on chest radiographs obtained after percutaneous transthoracic needle biopsy (PTNB) for pulmonary lesions.

METHODS: A CNN system for computer-aided diagnosis on chest radiographs was developed using the full 26-layer You Only Look Once model. A total of 1596 chest radiographs with pneumothorax were used for training. To validate the clinical feasibility of this model, follow-up chest radiographs obtained after PTNB for 1333 pulmonary lesions in 1319 patients in 2016 were prepared as an independent test set. Two experienced radiologists determined the presence of pneumothorax by consensus. The diagnostic performance of the CNN model was assessed using the jackknife free-response receiver operating characteristic method.

RESULTS: The incidence of pneumothorax was 17.9% (247/1379) on 3-h follow-up chest radiographs and 23.3% (309/1329) on 1-day follow-up chest radiographs. Twenty-three (1.7% of all PTNBs) cases required drainage catheter insertion. Our approach had a sensitivity, a specificity, and an area under the curve (AUC), respectively, of 61.1% (151/247), 93.0% (1053/1132), and 0.898 for 3-h follow-up chest radiographs and 63.4% (196/309), 93.5% (954/1020), and 0.905 for 1-day follow-up chest radiographs. The overall accuracy was 87.3% (1204/1379) for 3-h follow-up radiographs and 86.5% (1150/1329) for 1-day follow-up radiographs. The CNN model found all 23 cases of pneumothorax requiring drainage.

CONCLUSIONS: Our CNN model had good performance for detection of pneumothorax on chest radiographs after PTNB, especially for those requiring further procedures. It can be used as a screening tool prior to radiologist interpretation.

KEY POINTS: • The CNN model had good performance for detection of pneumothorax on chest radiographs after PTNB and showed high specificity and negative predictive value. • The CNN model found all cases of pneumothorax requiring drainage after PTNB. • The CNN model can be used as a screening tool prior to radiologist interpretation.