文献速递腹部胸部骨肌CT

常规腹部和胸部CT中的机会性骨质疏松筛查:20 000余名成人L1椎体骨小梁衰减值的正常参考范围

Opportunistic Osteoporosis Screening at Routine Abdominal and Thoracic CT: Normative L1 Trabecular Attenuation Values in More than 20 000 Adults.
PubMed 文献 · Radiology · 2019-03-26

本研究基于2000至2018年间20 374例120 kV腹部和/或胸部CT检查,建立全成人年龄段L1椎体骨小梁衰减值正常参考范围。L1平均衰减值随年龄线性下降,每年约2.5 HU,30岁以下平均226 HU±44,90岁及以上平均89 HU±38。女性绝经前平均L1衰减值高于男性(P < .008),绝经后两性相似。全自动测量较手动测量平均高21 HU(P < .004)。

要点

  • L1平均衰减值随年龄线性下降,每年约2.5 HU,可作为常规CT机会性骨质疏松筛查的快速参考。
  • 女性绝经前平均L1衰减值高于男性(P < .008),绝经后两性相似。
  • 全自动测量较手动测量平均高21 HU(P < .004),差异与横断面测量层面(椎体中部 vs 偏离中线层面)有关。

核心结论

  • 建立了全成人年龄段L1椎体骨小梁衰减值的正常参考范围,可在常规CT中作为快速参考,识别骨密度低、有骨质疏松风险的成人。

研究设计与样本

  • 参考数据来自2000至2018年间20 374例120 kV腹部和/或胸部CT检查,成人平均年龄60岁±12(标准差),女性占56.1%(11 428/20 374);检查含静脉对比剂4 263例、不含16 111例,临床指征多样且与骨质疏松无关;L1 Hounsfield单位测量采用定制自动化工具11 270例或由读片者手动测量9 104例;采用多变量logistic回归分析年龄、性别、对比剂及手动感兴趣区与全自动L1 Hounsfield单位测量的影响。

诊断标准与关键数值

  • L1平均衰减值随年龄线性下降,速率2.5 HU/年;30岁以下平均226 HU±44,90岁及以上平均89 HU±38。
  • 女性绝经前平均L1衰减值高于男性(P < .008),绝经后两组相似。
  • 静脉对比剂对平均L1衰减值影响可忽略,但40岁以下患者除外。
  • 全自动测量较手动测量平均高21 HU(P < .004),患者内亚组分析显示差异与横断面测量层面(椎体中部 vs 偏离中线层面)有关。

临床应用与阅片要点

  • 常规腹部和胸部CT(无论临床指征)可机会性测量L1椎体骨小梁衰减值,对照本参考范围识别骨密度低的成人。
  • 采用全自动工具测量时,所得L1衰减值平均较手动测量高21 HU(P < .004),报告解读时需注意测量方式差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Abdominal and thoracic CT provide a valuable opportunity for osteoporosis screening regardless of the clinical indication for imaging. Purpose To establish reference normative ranges for first lumbar vertebra (L1) trabecular attenuation values across all adult ages to measure bone mineral density (BMD) at routine CT. Materials and Methods Reference data were constructed from 20 374 abdominal and/or thoracic CT examinations performed at 120 kV. Data were derived from adults (mean age, 60 years ± 12 [standard deviation]; 56.1% [11 428 of 20 374] women). CT examinations were performed with (n = 4263) or without (n = 16 111) intravenous contrast agent administration for a variety of unrelated clinical indications between 2000 and 2018. L1 Hounsfield unit measurement was obtained either with a customized automated tool (n = 11 270) or manually by individual readers (n = 9104). The effects of patient age, sex, contrast agent, and manual region-of-interest versus fully automated L1 Hounsfield unit measurement were assessed using multivariable logistic regression analysis. Results Mean L1 attenuation decreased linearly with age at a rate of 2.5 HU per year, averaging 226 HU ± 44 for patients younger than 30 years and 89 HU ± 38 for patients 90 years or older. Women had a higher mean L1 attenuation compared with men (P < .008) until menopause, after which both groups had similar values. Administration of intravenous contrast agent resulted in negligible differences in mean L1 attenuation values except in patients younger than 40 years. The fully automated method resulted in measurements that were average 21 HU higher compared with manual measurement (P < .004); at intrapatient subanalysis, this difference was related to the level of transverse measurement used (midvertebra vs off-midline level). Conclusion Normative ranges of L1 vertebra trabecular attenuation were established across all adult ages, and these can serve as a quick reference at routine CT to identify adults with low bone mineral density who are at risk for osteoporosis. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Smith in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Jang S, Graffy PM, Ziemlewicz TJ, et al. Opportunistic Osteoporosis Screening at Routine Abdominal and Thoracic CT: Normative L1 Trabecular Attenuation Values in More than 20 000 Adults. Radiology. 2019. PMID: 30912719. doi:10.1148/radiol.2019181648

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。