发育性静脉异常周围T2加权成像异常高信号与其引流静脉磁敏感性的关系:在体定量磁敏感成像研究
回顾性分析27例偶然发现的发育性静脉异常(DVA)患者,按DVA邻近脑实质T2WI有无异常高信号分为水肿组(E+,9例)和无水肿组(E-,18例),采用3T MR定量磁敏感成像(QSM)测量引流静脉磁敏感性(χvein)。E+组χvein显著高于E-组(196.5 ± 27.9 vs. 167.7 ± 33.6,p = 0.036),且χvein与T2WI高信号面积呈线性相关(r = 0.633,95%CI 0.333-0.817,p < 0.001)。结论提示T2WI异常高信号的DVA引流静脉磁敏感值更高,可能反映氧摄取分数增高,可能与静脉淤血相关。
要点
- DVA伴T2WI邻近脑实质异常高信号者,其引流静脉QSM磁敏感值更高。
- χvein与T2WI高信号面积呈线性相关(r = 0.633,95%CI 0.333-0.817)。
- E+组引流静脉直径大于E-组(p = 0.006),且患者年龄更大(p = 0.006)。
核心结论
- T2WI上伴有异常高信号的DVA,其引流静脉磁敏感值更高,提示氧摄取分数增高,可能与静脉淤血相关。
研究设计与样本
- 回顾性分析连续27例偶然发现的DVA患者的脑MRI,按DVA邻近脑实质T2WI有无异常高信号分为水肿组(E+,n = 9)和无水肿组(E-,n = 18),使用3T MR采集全流补偿梯度回波图像用于磁敏感加权成像,源图像用于QSM处理,半自动测量引流静脉磁敏感性(χvein)并估算标准化χvein。
关键影像表现/征象
- DVA表现为引流静脉,E+组引流静脉直径大于E-组(p = 0.006)。
- E+组DVA邻近脑实质T2WI出现异常高信号,E-组无此表现。
- E+组χvein为196.5 ± 27.9,E-组为167.7 ± 33.6,E+组显著更高(p = 0.036)。
诊断标准与关键数值
- 以DVA邻近脑实质T2WI有无异常高信号定义水肿组(E+)与非水肿组(E-)。
- χvein与T2WI高信号面积呈线性相关(r = 0.633,95%CI 0.333-0.817,p < 0.001)。
- E+组χvein 196.5 ± 27.9 vs. E-组167.7 ± 33.6(p = 0.036)。
- E+组引流静脉直径大于E-组(p = 0.006),E+组患者年龄大于E-组(p = 0.006)。
临床应用与阅片要点
- 对偶然发现的DVA,可结合QSM测量的引流静脉磁敏感值及T2WI邻近实质信号评估。
- T2WI出现异常高信号时,引流静脉χvein可能更高(E+组196.5 ± 27.9 vs. E-组167.7 ± 33.6)。
- χvein与T2WI高信号面积相关(r = 0.633),高信号面积较大时引流静脉磁敏感值可能更高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: A developmental venous anomaly (DVA) is a vascular malformation of ambiguous clinical significance. We aimed to quantify the susceptibility of draining veins (χvein) in DVA and determine its significance with respect to oxygen metabolism using quantitative susceptibility mapping (QSM).
MATERIALS AND METHODS: Brain magnetic resonance imaging of 27 consecutive patients with incidentally detected DVAs were retrospectively reviewed. Based on the presence of abnormal hyperintensity on T2-weighted images (T2WI) in the brain parenchyma adjacent to DVA, the patients were grouped into edema (E+, n = 9) and non-edema (E-, n = 18) groups. A 3T MR scanner was used to obtain fully flow-compensated gradient echo images for susceptibility-weighted imaging with source images used for QSM processing. The χvein was measured semi-automatically using QSM. The normalized χvein was also estimated. Clinical and MR measurements were compared between the E+ and E- groups using Student's t-test or Mann-Whitney U test. Correlations between the χvein and area of hyperintensity on T2WI and between χvein and diameter of the collecting veins were assessed. The correlation coefficient was also calculated using normalized veins.
RESULTS: The DVAs of the E+ group had significantly higher χvein (196.5 ± 27.9 vs. 167.7 ± 33.6, p = 0.036) and larger diameter of the draining veins (p = 0.006), and patients were older (p = 0.006) than those in the E- group. The χvein was also linearly correlated with the hyperintense area on T2WI (r = 0.633, 95% confidence interval 0.333-0.817, p < 0.001).
CONCLUSION: DVAs with abnormal hyperintensity on T2WI have higher susceptibility values for draining veins, indicating an increased oxygen extraction fraction that might be associated with venous congestion.
引用
- Choi Y, Jang J, Nam Y, et al. Relationship between Abnormal Hyperintensity on T2-Weighted Images Around Developmental Venous Anomalies and Magnetic Susceptibility of Their Collecting Veins: In-Vivo Quantitative Susceptibility Mapping Study. Korean J Radiol. 2019. PMID: 30887748. doi:10.3348/kjr.2018.0685
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。