文献速递神经介入DSA

血流导向装置治疗后动脉瘤残留:临床与血管造影结局

Aneurysm Remnants after Flow Diversion: Clinical and Angiographic Outcomes.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-03-07

基于前瞻性维护的Pipeline Embolization Device数据库,回顾283例连续患者,6个月随访237例中62.4%完全闭塞(O'Kelly-Marotta D级),长期随访发现25例动脉瘤残留,无延迟破裂或其他临床后遗症;辅助弹簧圈栓塞、标签内使用及多枚装置重叠与更高完全闭塞率相关。

要点

  • 6个月随访237例中62.4%(148/237)达O'Kelly-Marotta D级完全闭塞。
  • 长期随访(中位16个月)发现25例动脉瘤残留,无延迟破裂或其他临床后遗症。
  • 标签内使用PED(P=0.04)和多枚装置重叠(P=0.02)与6个月完全闭塞率更高相关。

核心结论

  • 血流导向装置治疗后动脉瘤残留不常见且临床影响轻微;适当情况下,重叠装置和可能的辅助弹簧圈栓塞可能带来更高的完全闭塞率。

研究设计与样本

  • 回顾性分析前瞻性维护的Pipeline Embolization Device数据库(自建立至2017年10月),纳入283例连续患者,中位年龄55岁(四分位距47-65岁),女性87%(246/283);采用O'Kelly-Marotta量表进行独立盲法血管造影闭塞评估,统计采用Fisher精确检验和Mann-Whitney U检验(α=0.05)。

诊断标准与关键数值

  • 6个月随访影像 available 于83.7%(237/283)患者,完全闭塞(O'Kelly-Marotta D级)为62.4%(148/237)。
  • 辅助弹簧圈栓塞与6个月完全闭塞率较高相关(P=0.06)。
  • 标签内Pipeline Embolization Device使用与6个月完全闭塞率较高相关(P=0.04)。
  • 多枚装置重叠与6个月完全闭塞率较高相关(P=0.02)。
  • 长期随访影像(中位16个月,四分位距12-24个月)发现25例动脉瘤残留。

临床应用与阅片要点

  • 长期随访影像(中位16个月)可识别动脉瘤残留,本组25例残留患者中位临床随访31个月(四分位距23-33个月)均未出现延迟破裂或其他临床后遗症。
  • 作者认为,适当情况下重叠装置和可能的辅助弹簧圈栓塞可能带来更高的完全闭塞率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Flow diversion is an established method to treat complex intracranial aneurysms. The natural history of flow-diversion treatment failure resulting in aneurysm remnants is not well-defined. We aimed to delineate the clinical and angiographic features of this entity.

MATERIALS AND METHODS: Review of a prospectively maintained Pipeline Embolization Device data base from inception to October 2017 was performed for aneurysms that demonstrated residual filling on follow-up imaging. Procedural and follow-up clinical details were recorded. Independent, blinded, angiographic assessment of occlusion was performed on the basis of the O'Kelly-Marotta scale. Aggregated outcomes were analyzed using the Fisher exact and Mann-Whitney U tests for categoric and continuous variables, respectively (statistical significance, α = .05).

RESULTS: During the study period, 283 sequential patients were treated; 87% (246/283) were women. The median patient age was 55 years (interquartile range, 47-65 years). Six-month follow-up imaging was available in 83.7% (237/283) of patients, which showed 62.4% (148/237) complete occlusion (class D, O'Kelly-Marotta grading scale). Adjunctive coiling (P = .06), on-label Pipeline Embolization Device use (P = .04), and multiple device constructs (P = .02) had higher rates of complete occlusion at 6 months. Aneurysm remnants were identified in 25 cases on long-term follow-up imaging (median, 16 months; interquartile range, 12-24 months). No patient with an aneurysm remnant after flow diversion presented with delayed rupture or other clinical sequelae, with a median clinical follow-up of 31 months (interquartile range, 23-33 months).

CONCLUSIONS: Aneurysm remnants after flow diversion are infrequent with minimal clinical impact. When appropriate, the presence of overlapping devices and possibly adjunctive coiling may result in higher rates of complete occlusion.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Madaelil TP, Grossberg JA, Howard BM, et al. Aneurysm Remnants after Flow Diversion: Clinical and Angiographic Outcomes. AJNR Am J Neuroradiol. 2019. PMID: 30846433. doi:10.3174/ajnr.A6010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。