儿童尸检CT的诊断准确性:一项回顾性单中心研究
该单中心回顾性研究以尸检为参考标准,评估136例16岁以下儿童非增强全身尸检CT对主要病理诊断及死因的符合率。CT对主要病理发现的敏感度71.4%、特异度81.4%、符合率75.7%,对颅内和骨肌异常敏感度最高,对心脏和腹部最低。CT正确判断死因55/77例(71.4%),整体正确率40.4%。作者结论为CT与尸检符合率可接受,但整体死因识别率低。
要点
- 儿童尸检CT对主要病理发现的敏感度71.4%、特异度81.4%、符合率75.7%。
- 对颅内异常敏感度75.6%、骨肌异常98.4%,对心脏31.3%、腹部53.8%最低。
- CT正确判断死因55/77例(71.4%),整体136例中仅40.4%。
核心结论
- 儿童尸检CT与尸检的诊断符合率为71.4%,但整体死因识别率低至40.4%。
- 颅内和骨肌异常的诊断准确性最高。
研究设计与样本
- 单中心回顾性研究,纳入136例16岁以下儿童的非增强全身尸检CT及对应尸检报告,排除围产期死亡。
- 尸检CT由经验丰富的尸检放射科医生在不知尸检结果的情况下判读,以儿科病理医生尸检为参考标准。
- 主要结局为主要病理诊断或导致死因发现的符合性。
诊断标准与关键数值
- 主要病理发现:敏感度71.4%(95%CI 60.5-80.3%),特异度81.4%(95%CI 69.6-89.3%),阳性预测值83.3%(95%CI 72.6-90.4%),阴性预测值68.6%(95%CI 57.0-78.2%),符合率75.7%(95%CI 67.9-82.2%)。
- CT正确判断死因55/77例(71.4%),整体136例中40.4%。
- 按系统敏感度:颅内75.6%(95%CI 60.7-86.2%),骨肌98.4%(95%CI 91.4-99.7%),心脏31.3%(95%CI 14.2-55.6%),腹部53.8%(95%CI 29.1-78.6%)。
临床应用与阅片要点
- 儿童尸检CT对颅内和骨肌损伤导致的死亡判断准确性较高,多数正确死因为创伤性脑或身体损伤。
- 对心脏和腹部病变的敏感度较低,阅片时需注意这些区域的诊断局限。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The objective of our study was to determine the diagnostic accuracy of postmortem CT in children compared with standard autopsy. MATERIALS AND METHODS. This single-center retrospective study reviewed un-enhanced whole-body postmortem CT examinations of children less than 16 years old with corresponding autopsy reports irrespective of the clinical indication for referral for postmortem CT. Perinatal deaths were excluded. Postmortem CT was reported by experienced postmortem radiologists who were blinded to autopsy findings, with the primary outcome being concordance for the main pathologic diagnosis or findings leading to a cause of death. Autopsy performed by pediatric pathologists was the reference standard. RESULTS. One hundred thirty-six patients (74 [54.4%] male and 62 [45.6%] female patients) were included. The mean age of the 136 patients was 2 years 1 month (range, 2 days-14.7 years). A cause of death at autopsy was found for 77 of the 136 (56.6%) patients. Postmortem CT depicted a correct cause of death in 55 of 77 (71.4%) patients; (55/136 overall [40.4%]), with the majority attributable to traumatic brain or body injuries. For major pathologic findings, diagnostic accuracy rates were a sensitivity of 71.4% (95% CI, 60.5-80.3%), specificity of 81.4% (95% CI, 69.6-89.3%), positive predictive value of 83.3% (95% CI, 72.6-90.4%), negative predictive value of 68.6% (95% CI, 57.0-78.2%), and concordance rate of 75.7% (95% CI, 67.9-82.2%). The sensitivity of postmortem CT versus autopsy was highest for intracranial (75.6%; 95% CI, 60.7-86.2%) and musculoskeletal (98.4%; 95% CI, 91.4-99.7%) abnormalities and lowest for cardiac (31.3%; 95% CI, 14.2-55.6%) and abdominal (53.8%; 95% CI, 29.1-78.6%) findings. CONCLUSION. Postmortem CT gives an acceptable diagnostic concordance rate with autopsy of 71.4%, although identification of the cause of death overall was low at 40.4%. The highest accuracy rates were for intracranial and musculoskeletal abnormalities.
引用
- Shelmerdine SC, Davendralingam N, Palm L, et al. Diagnostic Accuracy of Postmortem CT of Children: A Retrospective Single-Center Study. AJR Am J Roentgenol. 2019. PMID: 30917029. doi:10.2214/AJR.18.20534
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。