弹簧圈填塞技术选择性栓塞脾动脉瘤:填塞密度对动脉瘤再灌注的影响及其在对比增强MR血管成像与数字减影血管造影间的相关性
本研究评估了16例使用可解脱微弹簧圈行真性脾动脉瘤栓塞的患者,比较单纯弹簧圈填塞与支架辅助弹簧圈隔绝两种方式。随访显示单纯填塞组动脉瘤填塞密度为20.10±8.05%,支架辅助组为32.90±11.95%(p=0.038);填塞密度≥29%的动脉瘤无论采用何种栓塞方式均未见瘤囊再灌注。作者认为填塞密度约达瘤腔体积四分之一时最有效,CE-MRA在检测再灌注和弹簧圈压缩方面优于DSA。
要点
- 填塞密度≥29%的脾动脉瘤无论采用单纯填塞或支架辅助隔绝,均未见瘤囊再灌注。
- CE-MRA在检测脾动脉瘤再灌注和弹簧圈压缩方面优于DSA。
- 随访时9例再灌注在全部CE-MRA和6例DSA检查中显示。
核心结论
- 脾动脉瘤弹簧圈填塞的良好中期结果似乎取决于弹簧圈填塞密度,弹簧圈体积约为动脉瘤体积四分之一时最有效;随访应采用CE-MRA,因其在检测动脉瘤再灌注和弹簧圈压缩方面优于DSA。
研究设计与样本
- 治疗性研究,证据等级IV;纳入16例真性脾动脉瘤患者(4例男性;平均年龄46.7岁),使用可解脱微弹簧圈(Concerto,Medtronic)行栓塞,分别采用单纯弹簧圈填塞(13例)或支架辅助弹簧圈隔绝(3例);术后3个月行CE-MRA和DSA并作相关性分析。
关键影像表现/征象
- 随访时7例(43.8%)达到动脉瘤完全闭塞。
- 9例(56.2%)出现瘤囊再灌注,全部在CE-MRA显示,其中6例在DSA显示。
- 单纯填塞组与支架辅助组在CE-MRA上瘤囊再灌注发生率存在显著差异(9 vs. 0)。
- 填塞密度≥29%的动脉瘤无论采用何种栓塞方法均未见瘤囊再灌注。
诊断标准与关键数值
- 单纯弹簧圈填塞组平均动脉瘤填塞密度为20.10±8.05%,支架辅助弹簧圈隔绝组为32.90±11.95%(p=0.038)。
- 填塞密度≥29%的动脉瘤无论采用单纯填塞或支架辅助隔绝,均未见瘤囊再灌注。
- CE-MRA在检测再灌注方面优于DSA:9例再灌注全部由CE-MRA显示,DSA仅显示6例。
临床应用与阅片要点
- 作者建议随访应采用CE-MRA,因其在检测动脉瘤再灌注和弹簧圈压缩方面优于DSA。
- 填塞密度≥29%的动脉瘤无论采用单纯填塞或支架辅助隔绝,均未见瘤囊再灌注。
- 作者认为弹簧圈体积约为动脉瘤体积四分之一时填塞最有效。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim was to evaluate the relationship between coil packing densities after splenic artery aneurysm (SAA) treatment using detachable microcoils and rates of SAA reperfusion and to suggest a post-treatment surveillance protocol using contrast-enhanced MRA.
MATERIALS AND METHODS: Evaluated were 16 patients (4 men; mean age 46.7), who underwent true SAA embolization using detachable microcoils (Concerto, Medtronic). SAAs were treated by selective coil packing (CP) or stent-assisted coil exclusion (SAC). Contrast-enhanced magnetic resonance angiography (CE-MRA) and digital subtraction angiography (DSA) were performed at 3 months post-procedure and correlated.
RESULTS: Primary CP was used in 13 patients, while SAC was used in three patients. On follow-up, complete aneurysm occlusion was seen in seven patients (43.8%). Sac reperfusion occurred in nine patients (56.2%) and was demonstrated in all CE-MRA and six DSA studies. Mean aneurysm packing density was 20.10 ± 8.05% for the CP group and 32.90 ± 11.95% for the SAC group (p = 0.038). There was a significant difference in the incidence of aneurysm sac reperfusion on CE-MRA study between CP and SAC (9 vs. 0). No sac reperfusion was seen in aneurysms with packing densities ≥ 29%, irrespective of either embolization method.
CONCLUSION: Favorable midterm results for coil packing of SAAs seem to depend on the coil packing density with a coil volume approximately a quarter of the aneurysm volume being most effective. Follow-up should involve the use of CE-MRA as this modality has been shown to be superior over DSA in detecting aneurysm reperfusion and coil compaction.
LEVEL OF EVIDENCE: Level IV, therapeutic study.
引用
- Wojtaszek M, Lamparski K, Wnuk E, et al. Selective occlusion of splenic artery aneurysms with the coil packing technique: the impact of packing density on aneurysm reperfusion correlated between contrast-enhanced MR angiography and digital subtraction angiography. Radiol Med. 2019. PMID: 30712163. doi:10.1007/s11547-019-00993-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。