文献速递儿科影像外周血管泌尿生殖USCT

肾多普勒超声与血浆肾素活性作为儿童肾血管性高血压筛查工具的診断作用

Diagnostic Role of Renal Doppler Ultrasound and Plasma Renin Activity as Screening Tools for Renovascular Hypertension in Children.
PubMed 文献 · J Ultrasound Med · 2019-02-18

本研究纳入336例因高血压行肾多普勒超声的儿童,按血浆肾素活性(PRA)分为高肾素组(n=177)和正常肾素组(n=159),以CTA为参考标准回顾性评估超声诊断价值。高肾素组超声敏感度84.2%、特异度93.6%;正常肾素组敏感度100.0%、特异度100.0%。作者认为高PRA患者行多普勒超声需谨慎以避免假阴性,正常PRA患者肾多普勒超声可能足以诊断肾血管性高血压而避免不必要的CTA。

要点

  • 高肾素组超声敏感度84.2%、特异度93.6%,需警惕假阴性。
  • 正常肾素组超声敏感度100.0%、特异度100.0%。
  • 假阴性病例中存在解剖变异(n=3)和段动脉狭窄(n=2)。

核心结论

  • 高PRA患者行多普勒超声需谨慎以避免假阴性检测;正常PRA患者肾多普勒超声可能足以诊断肾血管性高血压,从而避免不必要的CTA。

研究设计与样本

  • 回顾性研究,纳入336例因高血压行肾多普勒超声检查的儿童,按PRA分为高肾素组(n=177)和正常肾素组(n=159),并按年龄分层,以CTA为参考标准。

关键影像表现/征象

  • 高肾素组36例超声阳性,其中32例经CTA确认。
  • 正常肾素组10例超声阳性,其中9例经CTA确认。
  • 假阴性超声病例中,CTA确认解剖变异(n=3)和段动脉狭窄(n=2)。

诊断标准与关键数值

  • 高肾素组多普勒超声敏感度84.2%、特异度93.6%。
  • 正常肾素组超声敏感度100.0%、特异度100.0%。

临床应用与阅片要点

  • 高PRA患者行多普勒超声检查应谨慎,以避免假阴性。
  • 正常PRA患者肾多普勒超声可能足以诊断肾血管性高血压,避免不必要的CTA。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The diagnostic role of an ultrasound (US) and plasma renin activity (PRA) combination is unknown, despite the usefulness of Doppler US as a screening tool for renovascular hypertension (RVHT). The purpose of this study was to evaluate the diagnostic usefulness of US for RVHT in children stratified according to PRA.

METHODS: We identified 336 children who underwent renal Doppler US examinations for hypertension and divided them into a high-renin group (n = 177) and a normal-renin group (n = 159) based on PRA and stratified them by age. The Doppler US findings were retrospectively reviewed, and computed tomographic angiography (CTA) for the same children was used as the reference standard.

RESULTS: In the high-renin group, 36 patients had positive Doppler US findings that were confirmed by CTA in 32 cases. The sensitivity and specificity values for Doppler US in the high-renin group were 84.2% and 93.6%, respectively. In the normal-renin group, 10 patients had positive Doppler US findings; these positive findings were confirmed by CTA in 9 cases. The sensitivity and specificity values for US in the normal-renin group were 100.0% and 100.0%. There were anatomic variations (n = 3) and segmental artery stenosis (n = 2) among the cases with false-negative US findings, which were confirmed by CTA.

CONCLUSIONS: If patients have high PRA, a Doppler US examination should be performed with caution to avoid false-negative detection. If patients have normal PRA, renal Doppler US might be adequate for diagnosis of RVHT to avoid unnecessary CTA.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Lee S, Choi YH, Cho YJ, et al. Diagnostic Role of Renal Doppler Ultrasound and Plasma Renin Activity as Screening Tools for Renovascular Hypertension in Children. J Ultrasound Med. 2019. PMID: 30779189. doi:10.1002/jum.14966

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。