文献速递儿科影像头颈CT

婴儿中鼻道狭窄:鼻部测量指标的可靠性

Infant Midnasal Stenosis: Reliability of Nasal Metrics.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-02-14

本研究在50例患儿(11例梨状孔狭窄、10例Apert与Crouzon综合征、9例双侧后鼻孔闭锁、20例Pierre Robin序列征对照)的颌面部CT上测量梨状孔、后鼻孔及中鼻道各点,评估组间差异与测量信度。梨状孔狭窄及Apert与Crouzon综合征患者所有测量点均窄于对照(P < .001),双侧后鼻孔闭锁患者仅鼻后半部窄(P < .001)。中鼻道及梨状孔测量的组内与组间信度极好至优秀(ICC > 0.87),后鼻孔测量信度良好(ICC = 0.76-0.77);作者认为需进一步研究评估这些影像学发现的临床意义。

要点

  • 梨状孔狭窄及Apert、Crouzon综合征患儿鼻部各测量点均窄于对照(P < .001)。
  • 双侧后鼻孔闭锁患儿仅鼻后半部测量值窄于对照(P < .001)。
  • 中鼻道与梨状孔测量信度ICC > 0.87,后鼻孔测量ICC = 0.76-0.77。

核心结论

  • 梨状孔狭窄及Apert与Crouzon综合征患者在所有测量点均窄于对照,双侧后鼻孔闭锁患者仅鼻后半部窄;中鼻道及梨状孔测量信度极好至优秀,后鼻孔测量信度良好。

研究设计与样本

  • 便利样本研究,纳入50例患者(梨状孔狭窄11例、Apert与Crouzon综合征10例、双侧后鼻孔闭锁9例、Pierre Robin序列征对照20例),均行颌面部CT,在轴位及冠状位图像上于梨状孔、后鼻孔及定义的中鼻道点进行测量,以组内相关系数评估组内与组间信度,采用Bonferroni校正的t检验比较与对照的差异。

诊断标准与关键数值

  • 梨状孔狭窄及Apert与Crouzon综合征患者在各测量点均窄于对照(P < .001);双侧后鼻孔闭锁患者仅在鼻后半部窄于对照(P < .001);中鼻道及梨状孔测量组内与组间ICC > 0.87,后鼻孔测量ICC = 0.76-0.77。

局限性

  • 作者指出需进一步研究以评估这些影像学发现的临床意义。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Midnasal stenosis is a poorly defined entity that may be a component of other conditions of nasal obstruction contributing to respiratory distress in infants. We sought to establish whether midnasal vault narrowing is a component of well-defined syndromes of nasal narrowing, such as bilateral choanal atresia and pyriform aperture stenosis, and to characterize the nasal anatomy of patients with syndromic craniosynostosis.

MATERIALS AND METHODS: A convenience sample of patients with pyriform aperture stenosis, bilateral choanal atresia, and Apert and Crouzon syndromes with maxillofacial CT scans was identified. Patients with Pierre Robin Sequence were used as controls. Nasal measurements were performed at the pyriform aperture, choana, and defined midnasal points on axial and coronal CT scans. Intra- and interrater reliability was quantified with the intraclass correlation coefficient. T tests with Bonferroni adjustment were used to assess differences from controls.

RESULTS: The study included 50 patients: Eleven had pyriform aperture stenosis, 10 had Apert and Crouzon syndromes, 9 had choanal atresia, and 20 were controls. Measurements in patients with pyriform aperture stenosis and Apert and Crouzon syndromes were narrower than those of controls at all measured points (P < .001). Measurements in patients with choanal atresia were only narrow in the posterior half of the nose (P < .001). The intra- and interrater reliability of midnasal and pyriform measurements was very good to excellent (intraclass correlation coefficient > 0.87). The choanal measurement was good (intraclass correlation coefficient = 0.76-0.77).

CONCLUSIONS: Pyriform aperture stenosis, Apert and Crouzon patients were narrower at all measured points compared to controls. Bilateral choanal atresia patients were only narrower in the posterior half of the nose. More research is needed to evaluate the clinical implications of these radiographic findings.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Graham ME, Loveridge KM, Pollard SH, et al. Infant Midnasal Stenosis: Reliability of Nasal Metrics. AJNR Am J Neuroradiol. 2019. PMID: 30765383. doi:10.3174/ajnr.A5980