文献速递外周血管CTDSA

下肢流出道双能CT血管成像中改良钙减影算法对狭窄检出的诊断准确性影响

Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection.
PubMed 文献 · Eur Radiol · 2019-02-25

该回顾性研究纳入88例疑似外周动脉疾病患者,比较改良三物质分解钙减影与标准重建在下肢流出道双能CT血管成像中的诊断准确性,以DSA为参考标准。结果显示钙减影图像血管对比噪声比更高(15.3±7.3 vs 13.5±6.5,p<0.001),主观图像质量相当,在45例有DSA的患者中检出≥50%狭窄的敏感度、特异度、阳性预测值和阴性预测值分别为97.5%、95.6%、90.9%、98.1%,优于标准图像的98.8%、90.4%、82.3%、99.1%。

要点

  • 钙减影图像血管对比噪声比高于标准重建(15.3±7.3 vs 13.5±6.5,p<0.001)。
  • 两种重建主观图像质量评分相当(钙减影4.64 vs 标准4.57,p=0.220)。
  • 钙减影检出≥50%狭窄的敏感度97.5%、特异度95.6%、阳性预测值90.9%、阴性预测值98.1%。

核心结论

  • 改良三物质分解钙减影算法可提高下肢流出道双能CT血管成像的血管对比噪声比,主观图像质量与标准重建相当,对显著动脉狭窄的诊断准确性高于标准图像重建。

研究设计与样本

  • 经IRB批准、符合HIPAA的回顾性研究,纳入2014年5月至2015年5月间88例疑似外周动脉疾病患者(53例男性,平均年龄65.9±11岁),行下肢流出道双能CT血管成像,重建标准线性融合图像和钙减影图像,以数字减影血管造影为参考标准。

诊断标准与关键数值

  • 以DSA为参考标准,在45例患者中分析检出≥50%狭窄的诊断准确性:钙减影重建敏感度97.5%、特异度95.6%、阳性预测值90.9%、阴性预测值98.1%;标准图像敏感度98.8%、特异度90.4%、阳性预测值82.3%、阴性预测值99.1%。

临床应用与阅片要点

  • 钙减影重建可提高下肢流出道双能CT血管成像的血管对比噪声比,图像质量与标准重建相当。
  • 钙减影重建对显著动脉狭窄的诊断准确性高于标准图像重建,可减少因钙化斑块导致的狭窄程度高估和假阳性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the diagnostic accuracy of a modified three-material decomposition calcium subtraction (CS) algorithm for the detection of arterial stenosis in dual-energy CT angiography (DE-CTA) of the lower extremity runoff compared to standard image reconstruction, using digital subtraction angiography (DSA) as the reference standard.

METHODS: Eighty-eight patients (53 males; mean age, 65.9 ± 11 years) with suspected peripheral arterial disease (PAD) who had undergone a DE-CTA examination of the lower extremity runoff between May 2014 and May 2015 were included in this IRB-approved, HIPAA-compliant retrospective study. Standard linearly blended and CS images were reconstructed and vascular contrast-to-noise ratios (CNR) were calculated. Two independent observers assessed subjective image quality using a 5-point Likert scale. Diagnostic accuracy for ≥ 50% stenosis detection was analyzed in a subgroup of 45 patients who had undergone additional DSA. Diagnostic accuracy parameters were estimated with a random-effects logistic regression analysis and compared using generalized estimating equations.

RESULTS: CS datasets showed higher CNR (15.3 ± 7.3) compared to standard reconstructions (13.5 ± 6.5, p < 0.001). Both reconstructions showed comparable qualitative image quality scores (CS, 4.64; standard, 4.57; p = 0.220). Diagnostic accuracy (sensitivity, specificity, positive and negative predictive values) for CS reconstructions was 96.5% (97.5%, 95.6%, 90.9%, 98.1) and 93.1% (98.8%, 90.4%, 82.3%, 99.1%) for standard images.

CONCLUSIONS: A modified three-material decomposition CS algorithm provides increased vascular CNR, equivalent qualitative image quality, and greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff on DE-CTA compared with standard image reconstruction.

KEY POINTS: • Calcified plaques may lead to overestimation of stenosis severity and false positive results, requiring additional invasive digital subtraction angiography (DSA). • A modified three-material decomposition algorithm for calcium subtraction provides greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff compared with standard image reconstruction. • The application of this algorithm in patients with heavily calcified vessels may be helpful to potentially reduce inconclusive CT angiography examinations and the need for subsequent invasive DSA.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. De Santis D, De Cecco CN, Schoepf UJ, et al. Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection. Eur Radiol. 2019. PMID: 30805703. doi:10.1007/s00330-019-06032-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。