静脉注射对比剂与图像采集间隔延长导致幼年特发性关节炎患者磁共振成像滑膜厚度增加
研究纳入53例有现患或既往膝关节炎的幼年特发性关节炎患儿,在对比剂注射后约1分钟和约5分钟两个时间点测量髌股间室滑膜厚度。结果显示中位滑膜厚度从1.4 mm增至1.5 mm(P<0.001),重复测量组内相关系数分别为0.75和0.91(P<0.05)。结论认为增强后滑膜厚度测量具有时间依赖性,标准化采集时机对滑膜炎分级一致性很重要。
要点
- 增强后滑膜厚度测量随时间延长而增加:约1分钟时1.4 mm,约5分钟时1.5 mm(P<0.001)。
- 增强后约5分钟图像滑膜厚度重复测量ICC为0.91,高于约1分钟时的0.75。
- 为获得一致的滑膜炎分级,需标准化增强后图像采集时间。
核心结论
- 增强后滑膜厚度测量具有时间依赖性,标准化增强后图像采集时机对实现一致的滑膜炎分级很重要。
研究设计与样本
- 研究论文;53例有现患或既往膝关节炎的幼年特发性关节炎患儿,采用动态对比增强T1加权膝关节MR图像,在对比剂注射后约1分钟和约5分钟两个时间点测量滑膜厚度,由两名对时间点设盲的经验丰富阅片者独立测量。
关键影像表现/征象
- 髌股间室预定标记位置的滑膜厚度随增强后间隔延长而增加,中位滑膜厚度从约1分钟时的1.4 mm增至约5分钟时的1.5 mm(P<0.001)。
诊断标准与关键数值
- 53例患儿中位年龄13.5岁、59%为女性;约1分钟时间点滑膜厚度重复测量ICC为0.75(P<0.05),约5分钟时间点ICC为0.91(P<0.05);两个时间点滑膜厚度比较采用Wilcoxon符号秩检验。
临床应用与阅片要点
- 增强后滑膜厚度测量需注意采集时间点,不同时间点测值不同,报告和分级时应明确增强后采集时机。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Post-contrast synovial thickness measurement is necessary for scoring disease activity in juvenile idiopathic arthritis (JIA). However, the timing of post-contrast sequences varies widely among institutions. This variation in timing could influence thickness measurements.
OBJECTIVE: To measure thickness of the synovial membrane on early and late post-contrast knee magnetic resonance (MR) images of patients with JIA.
MATERIALS AND METHODS: Dynamic contrast-enhanced T1-weighted knee MR images of 53 children with JIA with current or past knee arthritis were used to study synovial thickness at time point 1 (about 1 min) and time point 2 (about 5 min after contrast administration). Two experienced readers, who were blinded for the time point, independently measured synovial thickness at a predefined, marked location in the patellofemoral compartment on randomized images. Synovial thickness at the two time points was compared using the Wilcoxon signed rank test. Repeatibility of the synovial thickness measurements was studied using intraclass correlation coefficients and Bland-Altman plots.
RESULTS: Median synovial thickness of the 53 patients (median age: 13.5 years, 59% female) increased with prolonged post-contrast interval with a synovial thickness of 1.4 mm at time point 1 and a synovial thickness of 1.5 mm at time point 2 (P<0.001). Repeated synovial thickness measurements showed an intraclass correlation coefficient (ICC) of 0.75, P<0.05 for time point 1 and an ICC of 0.91, P<0.05 for time point 2.
CONCLUSION: Post-contrast synovial membrane thickness measurements are time-dependent. Therefore, standardization of post-contrast image acquisition timing is important to achieve consistent grading of synovial inflammation.
引用
- Barendregt AM, van Gulik EC, Groot PFC, et al. Prolonged time between intravenous contrast administration and image acquisition results in increased synovial thickness at magnetic resonance imaging in patients with juvenile idiopathic arthritis. Pediatr Radiol. 2019. PMID: 30707259. doi:10.1007/s00247-018-04332-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。