髌腱-股骨外侧髁摩擦综合征的定量磁共振成像:与轻微髌股不稳定的关系
回顾性分析80例患者100个膝关节的MRI数据,测量7项髌股稳定性参数并与88个正常对照比较。髌腱-股骨外侧髁摩擦综合征组滑车深度、MT/LT比值、LPA及LTI角显著降低,Insall-Salvati比值显著升高,TT-TG距离及MH/LH比值无显著差异。研究证实该综合征与轻微髌股不稳定相关,并可在很大程度上解释其发病机制。
要点
- 髌腱-股骨外侧髁摩擦综合征组Insall-Salvati比值显著升高(p<0.001),AUC为0.925,诊断效能最高。
- 滑车深度、MT/LT比值、LPA及LTI角在病例组显著降低(p<0.001),AUC分别为0.784、0.8、0.731、0.675。
- TT-TG距离与MH/LH比值在病例组与对照组间无显著差异(p=0.231和0.073)。
核心结论
- 本研究通过测量髌股参数证实髌腱-股骨外侧髁摩擦综合征患者存在轻微髌股不稳定,该综合征与轻微髌股不稳定相关,并可在很大程度上解释其发病机制。
研究设计与样本
- 回顾性分析3年内数据库80例髌腱-股骨外侧髁摩擦综合征患者的100个膝关节MRI数据,并与88个正常对照比较;测量7项髌股稳定性参数并进行ROC曲线分析。
诊断标准与关键数值
- 髌腱-股骨外侧髁摩擦综合征组与对照组比较:滑车深度、MT/LT比值、LPA、LTI角显著降低(p<0.001),Insall-Salvati比值显著升高(p<0.001);TT-TG距离(p=0.231)和MH/LH比值(p=0.073)无显著差异;Insall-Salvati比值、滑车深度、MT/LT、LPA、LTI角的ROC曲线下面积分别为0.925、0.784、0.8、0.731、0.675。
临床应用与阅片要点
- 作者认为髌腱-股骨外侧髁摩擦综合征与轻微髌股不稳定相关,测量Insall-Salvati比值等髌股参数有助于评估该综合征患者的髌股稳定性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the correlation of patellar tendon-lateral femoral condyle friction syndrome (PTLFCFS) with subtle patellofemoral instability to explore its pathogenesis.
MATERIALS AND METHODS: One hundred knees of 80 patients with PTLFCFS were analyzed retrospectively by retrieving magnetic resonance imaging (MRI) data over a 3-year period from our database. Seven quantitative parameters for evaluating patellofemoral stability were measured on MR images, including the Insall-Salvati ratio, tibial tuberosity-trochlear groove (TT-TG) distance, trochlear groove depth, medial trochlear/lateral trochlear length (MT/LT) ratio, medial trochlear/lateral trochlear height (MH/LH) ratio, lateral patellofemoral angle (LPA), and lateral trochlear inclination (LTI) angle. These patellofemoral parameters of the PTLFCFS group and the normal control group were compared (n = 88), and receiving-operator characteristic (ROC) curve analysis was conducted to determine the specificity and sensitivity of these parameters.
RESULTS: The trochlear depth, MT/LT, LPA, and LTI angle were significantly lower (p < 0.001) and the Insall-Salvati ratio was significantly higher (p < 0.001) in the PTLFCFS group. However, the TT-TG distance and MH/LH ratio showed no significant difference (p = 0.231 and 0.073 respectively). The area under the ROC curve of the Insall-Salvati ratio, trochlear depth, MT/LT, LPA, and LTI angle were 0.925, 0.784, 0.8, 0.731, and 0.675 respectively. The efficiency of the Insall-Salvati ratio was the highest among those five parameters.
CONCLUSION: This study verified the presence of subtle patellofemoral instability by measuring various patellofemoral parameters in patients with PTLFCFS. It confirmed that PTLFCFS is associated with subtle patellofemoral instability and could largely explain the pathogenesis of PTLFCFS.
引用
- Li J, Sheng B, Yu F, et al. Quantitative magnetic resonance imaging in patellar tendon-lateral femoral condyle friction syndrome: relationship with subtle patellofemoral instability. Skeletal Radiol. 2019. PMID: 30715563. doi:10.1007/s00256-019-3163-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。