超声评估旋前方肌缝合在掌侧钢板内固定中的保护作用
本研究为单术者前瞻性系列,纳入2014年9月至2015年5月间20例桡骨远端骨折掌侧锁定钢板内固定患者,术中均修复旋前方肌。临床与超声随访未发现屈肌腱断裂或腱鞘炎,超声未见钢板与拇长屈肌腱接触的A型病例,多为无接触的C型;取钢板时旋前方肌缝合仍保持完好。作者认为旋前方肌修复是预防屈肌腱断裂的方法之一,外向走行缝线是有效缝合技术,超声可能有助于随访中发现无症状性屈肌腱刺激。
要点
- 掌侧钢板内固定后主要并发症为屈肌腱断裂,最常累及拇长屈肌腱。
- 旋前方肌修复是预防屈肌腱断裂的方法之一,外向走行缝线是有效缝合技术。
- 超声随访可能有助于发现无症状性屈肌腱刺激。
核心结论
- 旋前方肌修复是掌侧钢板内固定后预防屈肌腱断裂的方法之一,外向走行缝线是修复旋前方肌的有效技术,超声可能有助于随访中发现无症状性屈肌腱刺激。
研究设计与样本
- 单术者前瞻性系列,纳入2014年9月至2015年5月间20例连续桡骨远端骨折掌侧锁定钢板内固定患者,术中均修复旋前方肌,由同一术者进行临床、超声和围手术期屈肌腱评估。
关键影像表现/征象
- 超声未见钢板与拇长屈肌腱接触的A型病例,多为无接触的C型病例。
- 临床与超声评估均未发现屈肌腱断裂或腱鞘炎。
诊断标准与关键数值
- A型:超声显示钢板与拇长屈肌腱接触;C型:超声显示钢板与拇长屈肌腱无接触。
临床应用与阅片要点
- 超声随访可能有助于检测无症状性屈肌腱刺激。
- 取钢板时旋前方肌缝合仍保持完好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The main complication of volar locking plates for distal radius fractures is flexor tendon rupture. The flexor pollicis longus (FPL) is the most commonly ruptured. Repair of the pronator quadratus (PQ) is one of the ways to prevent tendon rupture. The main purpose of this series was to evaluate the role of PQ repair after volar plating to prevent flexor tendon rupture using ultrasound (US). This work was a mono-operator prospective series of 20 consecutive patients with volar locking plates for distal radius fracture between September 2014 and May 2015. The PQ was repaired in all patients. A clinical, ultrasound, and perioperative evaluation of the flexor tendon was performed by this same surgeon. There was no flexor tendon rupture or tenosynovitis. There were no type A cases, which are characterized by contact between the plate and the FPL, and mostly type C cases, which are characterized by no contact between the plate and the FPL on US imaging. The suture of the PQ was sustainable over time when we removed the plate. Pronator quadratus repair is one of the ways to prevent flexor tendon rupture after volar plating. The outward-running suture is an effective technique for repairing the PQ. Ultrasound may be helpful during follow-up to detect asymptomatic flexor tendon irritation.
引用
- Walch A, Erhard L, Vogels J, et al. Ultrasound Evaluation of the Protector Role of the Pronator Quadratus Suture in Volar Plating. J Ultrasound Med. 2019. PMID: 30779196. doi:10.1002/jum.14968
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。