3T场强四维磁共振成像对甲状旁腺腺瘤定位的诊断价值
本研究回顾性评估41例经手术证实的甲状旁腺病变患者术前3T四维磁共振成像(含动态增强与非增强序列)的定位价值。两位阅片者独立判读,单独非增强序列敏感度均为81.0%,联合动态增强后分别升至83.3%和85.7%;总体磁共振检出38个病灶,敏感度90.5%,阳性预测值95.0%。作者结论认为,含动态增强的四维磁共振成像是甲状旁腺腺瘤定位的可靠方法。
要点
- 3T四维磁共振成像联合动态增强序列对甲状旁腺腺瘤定位的总体敏感度为90.5%、阳性预测值为95.0%。
- 仅用非增强序列时两位阅片者敏感度均为81.0%,加做动态增强后分别提高至83.3%和85.7%。
- 联合动态增强序列的阅片者间一致性(ĸ=0.796)略优于单独非增强序列(ĸ=0.738)。
核心结论
- 含动态增强序列的四维磁共振成像是甲状旁腺腺瘤定位的可靠方法。
研究设计与样本
- 回顾性评估41例经手术证实的甲状旁腺病变患者的术前3T四维磁共振成像,包含动态增强序列与非增强序列(含T2加权多点Dixon序列,含同相位、反相位及水-only图像)。
诊断标准与关键数值
- 阅片者1单独判读非增强序列:正确检出34个甲状旁腺病灶,敏感度81.0%,阳性预测值87.2%。
- 阅片者2单独判读非增强序列:正确检出34个甲状旁腺病灶,敏感度81.0%,阳性预测值91.9%。
- 阅片者1联合动态增强序列:正确检出35个甲状旁腺病灶,敏感度83.3%,阳性预测值87.5%。
- 阅片者2联合动态增强序列:正确检出36个甲状旁腺病灶,敏感度85.7%,阳性预测值92.3%。
- 磁共振总体检出38个甲状旁腺病灶,敏感度90.5%,阳性预测值95.0%。
临床应用与阅片要点
- 两位阅片者均在非增强序列基础上加做动态增强序列后提高了甲状旁腺病灶的检出敏感度。
- 联合动态增强序列的阅片者间一致性(ĸ=0.796)略优于单独非增强序列(ĸ=0.738)。
局限性
- 本研究为回顾性评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this study was to assess the feasibility of four-dimensional magnetic resonance imaging (4D MRI) at 3 T for the localization of parathyroid adenomas.
MATERIALS AND METHODS: Preoperative 4D MRI scans, encompassing dynamic contrast-enhanced (DCE) sequences and non-contrast enhanced (non-CE) sequences, including a T2-weighted multipoint Dixon (T2-mDixon) sequence, with in-phase, out-phase, and water-only images, were evaluated retrospectively in 41 patients with surgically proven parathyroid lesions. Two readers who were blinded to the surgical findings independently reviewed the images in two sessions (non-CE sequences alone and non-CE + DCE sequences). The MRI localization of the suspected adenoma in each session and the consensus interpretation of the MRI images, were compared with the surgical results and interobserver agreement was assessed.
RESULTS: By interpreting the non-CE sequences alone, reader 1 correctly localized 34 parathyroid lesions (sensitivity 81.0%, positive predictive value (PPV) 87.2%), and reader 2 correctly localized 34 parathyroid lesions (sensitivity 81.0%, PPV 91.9%). With the addition of DCE sequences, reader 1 correctly identified 35 parathyroid lesions (sensitivity 83.3%, PPV 87.5%), while reader 2 correctly identified 36 parathyroid lesions (sensitivity 85.7%, PPV 92.3%). Overall, MRI detected 38 parathyroid lesions (sensitivity 90.5%, PPV 95.0%). Interobserver agreement was slightly superior in non-CE + DCE sequences compared to non-CE sequences alone (ĸ = 0.796 vs. ĸ = 0.738).
CONCLUSION: 4D MRI with DCE sequencing is a reliable method for the localization of parathyroid adenomas.
引用
- Ozturk M, Polat AV, Celenk C, et al. The diagnostic value of 4D MRI at 3T for the localization of parathyroid adenomas. Eur J Radiol. 2019. PMID: 30777212. doi:10.1016/j.ejrad.2019.01.022