文献速递甲状腺与浅表USPET

锝-99m SPECT/US 混合成像与传统诊断性甲状腺闪烁显像和超声成像的比较

Technetium-99m SPECT/US Hybrid Imaging Compared with Conventional Diagnostic Thyroid Imaging with Scintigraphy and Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2019-02-14

本研究前瞻性纳入79例患者,评估99mTcO4 SPECT/US融合成像在常规甲状腺诊断(B型超声、闪烁显像)结果不明确时的价值。SPECT/US在84%的病例中优于常规诊断,16%等效,67%的病例澄清了常规诊断后的问题;单发、双发和多发结节性甲状腺肿之间无统计学显著差异(p ≥ 0.3)。

要点

  • SPECT/US融合成像在84%病例中优于常规诊断,16%等效。
  • 67%的病例通过SPECT/US澄清了常规诊断后的问题。
  • 单发、双发和多发结节性甲状腺肿间无统计学显著差异(p ≥ 0.3)。

核心结论

  • SPECT/US融合成像可行,有助于澄清甲状腺结节功能评估中的不确定结果。

研究设计与样本

  • 前瞻性研究,纳入79例患者;对常规甲状腺诊断(B型超声、闪烁显像)结果不明确的患者行SPECT检查并传输至超声设备进行实时传感器导航三维融合超声检查,数据集按轮廓手动匹配。

关键影像表现/征象

  • 常规诊断后出现的问题在67%的病例中由SPECT/US澄清。

诊断标准与关键数值

  • 采用4点序数评分比较SPECT/US与常规诊断:SPECT/US远优于常规诊断、SPECT/US优于常规诊断、SPECT/US等于常规诊断、SPECT/US劣于常规诊断。
  • SPECT/US优于常规诊断(远优于或优于)占84%,等效占16%。
  • 单发、双发和多发结节性甲状腺肿之间无统计学显著差异(p ≥ 0.3)。

临床应用与阅片要点

  • 当常规甲状腺B型超声和闪烁显像对结节功能定位不确定时,SPECT/US融合成像可提供额外信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Side-by-side evaluation of thyroid ultrasound (US) and 99mTcO4 scintigraphy can lead to uncertainties in the correct topographic assignment of thyroid nodules. The aim of this study was to evaluate 99mTcO4 single-photon emission computed tomography/ultrasound (SPECT/US) fusion imaging. Seventy-nine patients were prospectively investigated. If conventional diagnostics of the thyroid gland (B-mode-US, scintigraphy) produced unclear findings, SPECT was performed and transferred to a US device for real-time sensor-navigated 3-D fusion US investigation. The data sets were manually matched according to their contours. Finally, SPECT/US versus conventional diagnostics was rated using an ordinal 4-point scale (SPECT/US >> conventional diagnostics, SPECT/US > conventional diagnostics, SPECT/US = conventional diagnostics, SPECT/US < conventional diagnostics). SPECT/US was superior (>>, >) in 84% and equivalent (=) in 16% of the cases, respectively. No statistically significant differences were observed for uni-, bi- and multinodular goiters (p ≥ 0.3). In 67%, the respective problem that arose after conventional diagnostics was clarified by SPECT/US. SPECT/US was feasible and was helpful for the clarification of uncertain functionality assessments of thyroid nodules.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Freesmeyer M, Winkens T, Kühnel C, et al. Technetium-99m SPECT/US Hybrid Imaging Compared with Conventional Diagnostic Thyroid Imaging with Scintigraphy and Ultrasound. Ultrasound Med Biol. 2019. PMID: 30773379. doi:10.1016/j.ultrasmedbio.2019.01.003