双能CT检测硅胶乳房假体破裂及硅胶淋巴结播散的能力
前瞻性研究纳入46例有硅胶假体且临床怀疑破裂或包膜外硅胶的患者,均行MRI后行平扫双能CT。以MRI、手术和病历建立参考标准,两名盲法阅片者用100分视觉量表判读。双能CT与MRI在假体破裂及区域淋巴结硅胶播散的AUC无显著差异。
要点
- 双能CT诊断假体破裂的AUC与MRI相近,可作为不能或不愿行MRI者的替代选择。
- 双能CT检测区域淋巴结硅胶播散的AUC与MRI无显著差异。
- 阅片前需经培训,并使用100分视觉量表评估诊断信心。
核心结论
- 双能CT在检测硅胶乳房假体破裂及区域淋巴结硅胶方面表现与MRI相似,可能成为不能或不愿接受MRI患者的替代选择。
研究设计与样本
- 前瞻性研究,连续纳入46例现有或既往硅胶假体且临床怀疑破裂或包膜外硅胶的患者,均先行MRI再行平扫双能CT,平均容积CT剂量指数8.2±2.0 mGy。
关键影像表现/征象
- 双能CT与MRI均用于评估假体包膜内或包膜外破裂及区域淋巴结硅胶播散。
诊断标准与关键数值
- 包膜内破裂AUC:MRI 0.958 vs 双能CT 0.989(p=0.28)。
- 包膜外破裂AUC:MRI 0.864 vs 双能CT 0.878(p=0.78)。
- 区域淋巴结硅胶播散AUC:MRI 0.823-0.866 vs 双能CT 0.892-0.906(p=0.34-0.54)。
临床应用与阅片要点
- 双能CT可作为不能或不愿接受MRI患者检测假体破裂及淋巴结硅胶的替代方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study is to compare the performance of dual-energy CT (DECT) with that of breast MRI for detection of silicone gel breast implant rupture and nodal spread of silicone.
SUBJECTS AND METHODS: This prospective study enrolled consecutive patients with current or prior silicone gel implants and clinical suspicion of implant rupture or extra-capsular silicone. All patients underwent MRI followed by unenhanced DECT. A breast radiologist not participating in image evaluation established reference standards for implant rupture (intra- or extracapsular) and regional nodal silicone spread (to axillary nodes and internal mammary [IM] and mediastinal nodes) using MRI, surgical findings, and medical records. After undergoing reader training, two radiologists who were blinded to all medical records interpreted randomized images in two sessions, indicating confidence in diagnosis using a 100-point visual scale.
RESULTS: A total of 46 patients who had a subpectoral silicone gel implant (n = 31), a subglandular silicone gel implant (n = 14), or a silicone gel implant that was removed (n = 1) underwent MRI and DECT (mean [± SD] volume CT dose index, 8.2 ± 2.0 mGy). Nineteen patients had implant rupture, and 13 of these patients had silicone within the IM or axillary nodes. Pooled data showed no significant difference between MRI and DECT interpretation of intra- or extracapsular rupture of implants (AUC value for intracapsular rupture, 0.958 [for MRI] vs 0.989 [for DECT]; p = 0.28; AUC value for extracapsular rupture, 0.864 [for MRI] vs 0.878 [for DECT]; p = 0.78). No difference was noted in the AUC value for silicone spread to regional lymph nodes: 0.823-0.866 [for MRI] vs 0.892-0.906 [for DECT]; p = 0.34-0.54).
CONCLUSION: DECT performs similar to MRI for the detection of silicone gel implant rupture and the presence of silicone in regional lymph nodes, and it may be an alternative for patients who are unable or unwilling to undergo MRI.
引用
- Glazebrook KN, Doerge S, Leng S, et al. Ability of Dual-Energy CT to Detect Silicone Gel Breast Implant Rupture and Nodal Silicone Spread. AJR Am J Roentgenol. 2019. PMID: 30779664. doi:10.2214/AJR.18.20138
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。