利用基于大小的硬度梯度阈值重新分类BI-RADS 3-4b病变可提高诊断性能
研究纳入227例连续女性、234个BI-RADS 3-5实性乳腺病变,在超声引导活检前行剪切波弹性成像,基于病理比较硬度梯度、BI-RADS及二者联合的诊断性能。结果显示硬度梯度AUC为0.939,优于SD的0.897和彩色模式的0.852;按病变大小设定阈值(>15 mm为82.5 kPa,≤15 mm为51.1 kPa)重新分类BI-RADS 3-4b病变后,特异度和AUC较单用BI-RADS显著提高,敏感度无显著下降。
要点
- 硬度梯度与弹性标准差高度相关(r=0.90),与Tozaki彩色模式分类相关(r=0.64)。
- 硬度梯度AUC 0.939,优于SD的0.897和彩色模式的0.852。
- 按大小阈值重新分类BI-RADS 3-4b后特异度和AUC显著提高,敏感度无显著下降。
核心结论
- 硬度梯度对实性乳腺病变的鉴别能力优于SD或四色模式分类,应用其大小特异性阈值对BI-RADS 3-4b病变进行分类可提高诊断性能。
研究设计与样本
- 连续纳入227例女性,在超声引导活检前行剪切波弹性成像,分析234个BI-RADS 3-5实性乳腺病变,以组织病理学为参考标准进行ROC曲线分析,比较SWE、BI-RADS及二者联合的诊断性能。
诊断标准与关键数值
- 硬度梯度与病变大小显著相关(r=0.394,p<0.001),据此设定大小阈值:病变>15 mm为82.5 kPa,病变≤15 mm为51.1 kPa。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the role of utilizing size-based thresholds of stiffness gradient in diagnosing solid breast lesions and optimizing original Breast Imaging-Reporting And Data System (BI-RADS) classifications.
MATERIALS AND METHODS: Two-hundred and twenty-seven consecutive women underwent shear-wave elastography (SWE) before ultrasound-guided biopsy, and 234 solid breast lesions categorized as BI-RADS 3-5 were analysed. Receiver operating characteristic curve analysis was performed based on histopathology. Diagnostic performance among SWE, BI-RADS, and their combination were compared.
RESULTS: The stiffness gradient correlated with the standard deviation of elasticity (SD, r=0.90), and with Tozaki's pattern classification (r=0.64). The area under the receiver operating characteristic curves (AUC) for stiffness gradient (0.939) outperformed SD (0.897) or colour pattern (0.852). Due to significant association with lesion size (r=0.394, p<0.001), stiffness gradient's size-based thresholds (lesions >15 mm: 82.5 kPa; lesions ≤15 mm: 51.1 kPa) were established to reclassify BI-RADS 3-4b lesions. Upgrading category 3 lesions (over the corresponding cut-off value, 3 to 4a) and downgrading categories 4a-4b lesions (less than or equal to the corresponding cut-off value, 4b to 4a, 4a to 3), yielded significant improvement in specificity (90.28% versus 77.78%, p<0.001) and AUC (0.948 versus 0.926, p=0.035) than BI-RADS alone. No significant loss emerged in the sensitivity (88.89% versus 91.11%, p=0.500).
CONCLUSION: Stiffness gradient exhibited better discriminatory ability than SD or four-colour pattern classification in determining solid breast lesions and applying its size-specific thresholds to categorize BI-RADS 3-4b lesions could improve diagnostic performance.
引用
- Shang J, Ruan LT, Wang YY, et al. Utilizing size-based thresholds of stiffness gradient to reclassify BI-RADS category 3-4b lesions increases diagnostic performance. Clin Radiol. 2019. PMID: 30755314. doi:10.1016/j.crad.2019.01.004