文献速递乳腺MR

乳腺癌磁共振成像表观扩散系数与肿瘤浸润淋巴细胞的相关性

Correlation between apparent diffusion coefficient of magnetic resonance imaging and tumor-infiltrating lymphocytes in breast cancer.
PubMed 文献 · Radiol Med · 2019-02-26

这项4年回顾性研究纳入125例接受根治性或改良根治性乳房切除术的单灶性乳腺癌患者,术前均使用同一台1.5-T磁共振仪及相同方案(STIR、DWI、DCE序列)行MRI检查。按TIL评分分为缺失-低TIL组(≤10%)和中-高TIL组(>10%),缺失-低TIL组平均ADC值低于中-高TIL组(0.96±0.18×10⁻³ mm²/s vs 1.14±0.16×10⁻³ mm²/s,p<0.0001),区分两组的ADC阈值为1.03×10⁻³ mm²/s,敏感度67.8%、特异度80.3%。

要点

  • 缺失-低TIL组平均ADC值0.96±0.18×10⁻³ mm²/s,低于中-高TIL组的1.14±0.16×10⁻³ mm²/s(p<0.0001)。
  • 区分缺失-低TIL与中-高TIL的ADC阈值为1.03×10⁻³ mm²/s,敏感度67.8%、特异度80.3%。
  • ADC值与TIL水平(p<0.0001)及癌组织学类型(p=0.0006)显著相关,低ADC值对应缺失-低TIL和导管型。

核心结论

  • 缺失-低TIL的乳腺癌平均ADC值显著低于中-高TIL者,区分两组的ADC阈值为1.03×10⁻³ mm²/s。

研究设计与样本

  • 4年回顾性研究,纳入125例因单灶性乳腺癌行根治性或改良根治性乳房切除术的患者。
  • 所有患者术前均使用同一台1.5-T磁共振仪及相同方案行MRI检查,序列包括STIR、DWI和DCE。

关键影像表现/征象

  • 缺失-低TIL组平均ADC值为0.96±0.18×10⁻³ mm²/s,中-高TIL组为1.14±0.16×10⁻³ mm²/s,缺失-低TIL组更低(p<0.0001)。
  • 全部乳腺癌平均ADC值为1.05±0.19×10⁻³ mm²/s。

诊断标准与关键数值

  • 按TIL评分将乳腺癌分为缺失-低TIL组(≤10%)和中-高TIL组(>10%)。
  • 区分两组的ADC阈值为1.03×10⁻³ mm²/s,敏感度67.8%、特异度80.3%。
  • ADC值与TIL水平显著相关(p<0.0001),与癌组织学类型显著相关(p=0.0006),低平均ADC值对应缺失-低TIL水平和导管型。

临床应用与阅片要点

  • 缺失-低TIL组66例(52.8%),中-高TIL组59例(47.2%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate a possible correlation between apparent diffusion coefficient (ADC) value and tumor-infiltrating lymphocytes (TILs) level in breast cancer (BC). A second objective was to assess whether there were other histopathologic features that could affect mean ADC value.

METHODS: In this 4-year retrospective study were included 125 patients who underwent radical or modified mastectomy for monofocal BC. All subjects had performed preoperative MRI with the same 1.5-T machine and protocol, which consisted of STIR, DWI and DCE sequences. Based on TIL score, BCs were stratified into two groups: absent-low TIL (≤ 10%) and medium-high TIL (> 10%). The t test was used to correlate mean ADC value with TIL groups. Receiver operating characteristic curve and Youden index were used in order to identify ADC value threshold to distinguish the two TIL groups.

RESULTS: BC patients with absent-low TIL level and medium-high TIL one were, respectively, 66 (52.8%) and 59 (47.2%). Mean ADC value was 1.05 ± 0.19 * 10-3 mm2 s-1. Absent-low TIL group showed a lower mean ADC value than medium-high TIL one (0.96 ± 0.18 * 10-3 mm2 s-1 vs 1.14 ± 0.16 * 10-3 mm2 s-1; p < 0.0001). ADC value threshold in order to distinguish the two TIL groups with maximum sensitivity (67.8%) and specificity (80.3%) was 1.03 * 10-3 mm2 s-1. ADC value was shown to be significantly related to TILs level (p < 0.0001) and cancer histotype (p = 0.0006), with a lower mean ADC value correlated to absent-low TIL level and ductal histotype.

CONCLUSION: BCs with absent-low TIL showed a statistically significant lower mean ADC value than those with medium-high TIL. ADC value threshold in order to distinguish these two groups was 1.03 * 10-3 mm2 s-1.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Fogante M, Tagliati C, De Lisa M, et al. Correlation between apparent diffusion coefficient of magnetic resonance imaging and tumor-infiltrating lymphocytes in breast cancer. Radiol Med. 2019. PMID: 30806920. doi:10.1007/s11547-019-01008-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。