乳腺癌数字乳腺X线摄影:乳腺实质影像组学的附加价值
该回顾性研究纳入182例患者(106个恶性、76个良性病灶),评估对侧乳腺实质影像组学特征联合病灶特征能否提升数字乳腺X线摄影的良恶性分类效能;联合分类器的AUC为0.84±0.03,优于单独病灶特征的0.79±0.03(P=.047)。
要点
- 联合对侧乳腺实质影像组学特征后,良恶性病灶分类AUC由0.79±0.03提升至0.84±0.03(P=.047)。
- 联合特征集中入选频率超过50%的特征包括毛刺、边缘锐利度、大小、圆形度、偏度与幂律beta。
- 对侧乳腺实质纹理特征可能反映与乳腺癌发生相关的生物学风险因素。
核心结论
- 将肿瘤的定量影像组学数据与对侧乳腺实质特征相结合,可能提高乳腺癌的诊断准确度。
研究设计与样本
- 符合HIPAA的回顾性研究,纳入2002年6月至2009年7月间接受乳腺X线摄影的182例患者(年龄25-90岁,平均55.9岁±14.9),共106个恶性与76个良性病灶;对每个病灶行自动分割与影像组学分析,并对对侧乳腺实质正常感兴趣区行纹理分析;采用贝叶斯人工神经网络分类器,以留一患者法评估,以受试者工作特征曲线下面积(AUC)为评价指标。
诊断标准与关键数值
- 联合病灶与实质分类器鉴别乳腺X线良恶性病灶的AUC为0.84±0.03,单独病灶特征为0.79±0.03,两者差异有统计学意义(P=.047)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Previous studies have suggested that breast parenchymal texture features may reflect the biologic risk factors associated with breast cancer development. Therefore, combining the characteristics of normal parenchyma from the contralateral breast with radiomic features of breast tumors may improve the accuracy of digital mammography in the diagnosis of breast cancer. Purpose To determine whether the addition of radiomic analysis of contralateral breast parenchyma to the characterization of breast lesions with digital mammography improves lesion classification over that with radiomic tumor features alone. Materials and Methods This HIPAA-compliant, retrospective study included 182 patients (age range, 25-90 years; mean age, 55.9 years ± 14.9) who underwent mammography between June 2002 and July 2009. There were 106 malignant and 76 benign lesions. Automatic lesion segmentation and radiomic analysis were performed for each breast lesion. Radiomic texture analysis was applied in the normal regions of interest in the contralateral breast parenchyma to assess the mammographic parenchymal patterns. The classification performance of both individual features and the output from a Bayesian artificial neural network classifier was evaluated with the leave-one-patient-out method by using the area under the receiver operating characteristic curve (AUC) as the figure of merit in the task of differentiating between malignant and benign lesions. Results The performance of the combined lesion and parenchyma classifier in the differentiation between malignant and benign mammographic lesions was better than that with the lesion features alone (AUC = 0.84 ± 0.03 vs 0.79 ± 0.03, respectively; P = .047). Overall, six radiomic features-spiculation, margin sharpness, size, circularity from the tumor feature set, and skewness and power law beta from the parenchymal feature set-were selected more than 50% of the time during the feature selection process on the combined feature set. Conclusion Combining quantitative radiomic data from tumors with contralateral parenchyma characterizations may improve diagnostic accuracy for breast cancer. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Shaffer in this issue.
引用
- Li H, Mendel KR, Lan L, et al. Digital Mammography in Breast Cancer: Additive Value of Radiomics of Breast Parenchyma. Radiology. 2019. PMID: 30747591. doi:10.1148/radiol.2019181113
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。