文献速递乳腺乳腺X线

数字乳腺断层摄影:放射科医师的学习曲线

Digital Breast Tomosynthesis: Radiologist Learning Curve.
PubMed 文献 · Radiology · 2019-02-26

本前瞻性研究纳入2010至2017年间271362名女性的106126次DBT与221248次DM检查,由53家机构的104名放射科医师判读,评估采用DBT后2年内累积判读量对召回率和癌症检出率的影响。结果显示DBT召回率低于DM(9.4% vs 10.4%,P=.02),癌症检出率相似;累积DBT量<400例时召回率即下降(OR=0.83),且随累积量增加持续保持较低水平。

要点

  • DBT召回率低于DM(9.4% vs 10.4%,P=.02),癌症检出率相似(4.6 vs 4.0每千次筛查,P=.12)。
  • 累积DBT量<400例时召回率即低于DM(OR=0.83),随累积量增加持续保持较低水平(P<.001)。
  • 非致密型乳腺召回率下降幅度大于致密型乳腺(OR范围0.68-0.76 vs 0.86-0.90,交互P<.001)。

核心结论

  • 采用DBT后的早期性能改善在不同DBT累积量、放射科医师亚专科和乳腺密度下均得以持续。
  • DBT召回率低于DM,癌症检出率与DM相似。

研究设计与样本

  • 前瞻性研究,纳入2010至2017年间271362名女性(平均年龄57.5岁)的106126次DBT和221248次DM检查。
  • 由53家机构的104名放射科医师判读,数据来自乳腺癌症监测联盟。
  • 采用条件logistic回归估计放射科医师内累积DBT量对召回率和癌症检出率的影响,并校正检查层面特征。

诊断标准与关键数值

  • 采用DBT前DM召回率为10.4%(95%CI:9.5%,11.4%),癌症检出率为每千次筛查4.0例(95%CI:3.6,4.5)。
  • 采用DBT后DBT召回率为9.4%(95%CI:8.2%,10.6%;P=.02),癌症检出率为每千次筛查4.6例(95%CI:4.0,5.2;P=.12)。
  • 相对DM,累积DBT量<400例时召回率OR=0.83(95%CI:0.78,0.89);400-799例OR=0.8(95%CI:0.75,0.85);800-1199例OR=0.81(95%CI:0.76,0.87);1200-1599例OR=0.78(95%CI:0.73,0.84);1600-2000例OR=0.81(95%CI:0.75,0.88);P<.001。
  • 乳腺影像亚专科医师OR范围0.67-0.85(P<.02),非乳腺影像专科医师OR范围0.80-0.85(P<.001)。
  • 非致密型乳腺OR范围0.68-0.76(P<.001),致密型乳腺OR范围0.86-0.90(P≤.05),交互作用P<.001。

临床应用与阅片要点

  • 采用DBT后早期即可观察到召回率下降,且该改善在不同累积判读量下持续存在。
  • 放射科医师亚专科和乳腺密度不影响DBT召回率改善的持续性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background There is growing evidence that digital breast tomosynthesis (DBT) results in lower recall rates and higher cancer detection rates when compared with digital mammography. However, whether DBT interpretative performance changes with experience (learning curve effect) is unknown. Purpose To evaluate screening DBT performance by cumulative DBT volume within 2 years after adoption relative to digital mammography (DM) performance 1 year before DBT adoption. Materials and Methods This prospective study included 106 126 DBT and 221 248 DM examinations in 271 362 women (mean age, 57.5 years) from 2010 to 2017 that were interpreted by 104 radiologists from 53 facilities in the Breast Cancer Surveillance Consortium. Conditional logistic regression was used to estimate within-radiologist effects of increasing cumulative DBT volume on recall and cancer detection rates relative to DM and was adjusted for examination-level characteristics. Changes were also evaluated by subspecialty and breast density. Results Before DBT adoption, DM recall rate was 10.4% (95% confidence interval [CI]: 9.5%, 11.4%) and cancer detection rate was 4.0 per 1000 screenings (95% CI: 3.6 per 1000 screenings, 4.5 per 1000 screenings); after DBT adoption, DBT recall rate was lower (9.4%; 95% CI: 8.2%, 10.6%; P = .02) and cancer detection rate was similar (4.6 per 1000 screenings; 95% CI: 4.0 per 1000 screenings, 5.2 per 1000 screenings; P = .12). Relative to DM, DBT recall rate decreased for a cumulative DBT volume of fewer than 400 studies (odds ratio [OR] = 0.83; 95% CI: 0.78, 0.89) and remained lower as volume increased (400-799 studies, OR = 0.8 [95% CI: 0.75, 0.85]; 800-1199 studies, OR = 0.81 [95% CI: 0.76, 0.87]; 1200-1599 studies, OR = 0.78 [95% CI: 0.73, 0.84]; 1600-2000 studies, OR = 0.81 [95% CI: 0.75, 0.88]; P < .001). Improvements were sustained for breast imaging subspecialists (OR range, 0.67-0.85; P < .02) and readers who were not breast imaging specialists (OR range, 0.80-0.85; P < .001). Recall rates decreased more in women with nondense breasts (OR range, 0.68-0.76; P < .001) than in those with dense breasts (OR range, 0.86-0.90; P ≤ .05; P interaction < .001). Cancer detection rates for DM and DBT were similar, regardless of DBT volume (P ≥ .10). Conclusion Early performance improvements after digital breast tomosynthesis (DBT) adoption were sustained regardless of DBT volume, radiologist subspecialty, or breast density. © RSNA, 2019 See also the editorial by Hooley in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Miglioretti DL, Abraham L, Lee CI, et al. Digital Breast Tomosynthesis: Radiologist Learning Curve. Radiology. 2019. PMID: 30806595. doi:10.1148/radiol.2019182305

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。