利用影像组学和机器学习在平扫低剂量CT上鉴别肾结石与静脉石
本研究从两个连续独立队列的平扫低剂量CT图像中半自动分割肾结石和静脉石并提取影像组学特征,用第一队列(369例)训练机器学习模型区分肾结石(211例)与静脉石(201例),在第二独立队列(肾结石24例、静脉石23例)测试,测试集总体准确率85.1%,AUC 0.902,PPV 81.5%,NPV 90.0%。
要点
- 平扫低剂量CT上肾结石与静脉石鉴别困难,影像组学联合机器学习模型测试集AUC 0.902。
- 模型测试集准确率85.1%、PPV 81.5%、NPV 90.0%,置换检验p<0.05优于随机。
- 模型在外部独立队列中验证,对CT采集与重建方案表现稳健。
核心结论
- 影像组学与机器学习可在因急性腰痛行平扫低剂量CT的患者中准确鉴别肾结石与静脉石。
研究设计与样本
- 影像组学研究,两个连续独立队列,第一队列369例用于训练,第二独立队列为测试集。
- 对腹部盆腔钙化行半自动分割后提取影像组学特征。
- 训练集肾结石211例、静脉石201例;测试集肾结石24例、静脉石23例。
关键影像表现/征象
- 原文未报告具体影像征象,仅基于半自动分割提取的影像组学特征进行分类。
诊断标准与关键数值
- 测试集总体准确率85.1%,AUC 0.902,PPV 81.5%,NPV 90.0%。
- 置换检验p<0.05(原文写作permutation p value),分类准确率显著优于随机。
临床应用与阅片要点
- 作者认为该模型有潜力作为未来疑似肾绞痛患者腹部盆腔可疑钙化的诊断工具。
- 模型在外部独立队列中验证,对CT采集与重建方案表现稳健。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Distinguishing between kidney stones and phleboliths can constitute a diagnostic challenge in patients undergoing unenhanced low-dose CT (LDCT) for acute flank pain. We sought to investigate the accuracy of radiomics and a machine-learning classifier in differentiating between kidney stones and phleboliths on LDCT.
METHODS: Radiomics features were extracted following a semi-automatic segmentation of kidney stones and phleboliths for two independent consecutive cohorts of patients undergoing LDCT for acute flank pain. Radiomics features from the first cohort of patients (n = 369) were ultimately used to train a machine-learning model designed to distinguish kidney stones (n = 211) from phleboliths (n = 201). Classification performance was assessed on the second independent cohort (i.e., testing set) (kidney stones n = 24; phleboliths n = 23) using positive and negative predictive values (PPV and NPV), area under the receiver operating curves (AUC), and permutation testing.
RESULTS: Our machine-learning classification model trained on radiomics features achieved an overall accuracy of 85.1% on the independent testing set, with an AUC of 0.902, PPV of 81.5%, and NPV of 90.0%. Classification accuracy was significantly better than chance on permutation testing (p < 0.05, permutation p value).
CONCLUSION: Radiomics and machine learning enable accurate differentiation between kidney stones and phleboliths on LDCT in patients presenting with acute flank pain.
KEY POINTS: • Combining a machine-learning algorithm with radiomics features extracted for abdominopelvic calcification on LDCT offers a highly accurate method for discriminating phleboliths from kidney stones. • Our radiomics and machine-learning model proved robust for CT acquisition and reconstruction protocol when tested in comparison with an external independent cohort of patients with acute flank pain. • The high performance of the radiomics-based automatic classification model in differentiating phleboliths from kidney stones indicates its potential as a future diagnostic tool for equivocal abdominopelvic calcifications in the setting of suspected renal colic.
引用
- De Perrot T, Hofmeister J, Burgermeister S, et al. Differentiating kidney stones from phleboliths in unenhanced low-dose computed tomography using radiomics and machine learning. Eur Radiol. 2019. PMID: 30747299. doi:10.1007/s00330-019-6004-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。