文献速递技术与安全腹部CT

影像诊断中的床旁肌酐检测:门诊CT环境下的一项可行性研究

Point of care creatinine testing in diagnostic imaging: A feasibility study within the outpatient computed tomography setting.
PubMed 文献 · Eur J Radiol · 2019-01-08

本研究在门诊CT增强扫描流程中评估床旁肌酐检测联合筛查问卷的可行性。8周内纳入300例成人门诊患者,14例(4.7%)扫描当日eGFR低于45mL/min/1.73m²且均经筛查识别;床旁检测与实验室检测的恒定误差为-3.71(95%CI:-6.41至-0.50)。结论认为床旁肌酐检测在放射科环境中可行。

要点

  • 扫描当日eGFR低于45mL/min/1.73m²的14例患者(4.7%)均通过筛查问卷识别。
  • 床旁检测与实验室检测的恒定误差为-3.71(95%CI:-6.41至-0.50)。
  • 281/300例(93.7%)患者基于既往与扫描当日血结果归入同一风险类别。

核心结论

  • 床旁肌酐检测是确保肾功能的实用方法,在放射科环境中可行。

研究设计与样本

  • 可行性研究,8周内纳入300例成人门诊患者,在英国CT部门接受增强扫描,完成筛查问卷并同意床旁与实验室肌酐检测,与既往3个月内基线血检比较,并邀请48-72小时随访复查。

诊断标准与关键数值

  • 扫描当日eGFR低于45mL/min/1.73m²者14例(4.7%),均经筛查识别;281/300例(93.7%)基于既往与扫描当日血结果归入同一风险类别。

临床应用与阅片要点

  • 床旁肌酐检测联合筛查问卷可用于门诊CT增强扫描前肾功能筛查;扫描当日共记录6例床旁检测失败。

局限性

  • 扫描当日共记录6例床旁检测失败。
  • 5例患者造影后肌酐较基线升高≥25%,但未识别出造影后急性肾损伤(较基线≥50%)病例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: Although the risks associated with iodinated contrast administration are acknowledged to be very low, screening of kidney function prior to administration is still standard practice in many hospitals. This study has evaluated the feasibility of implementing a screening form in conjunction with point of care (PoC) creatinine testing as a method to manage the risks of post contrast acute kidney injury (PC-AKI) within the CT imaging pathway.

METHOD: Over an eight-week period 300 adult outpatients attending a UK CT department for contrast-enhanced scans were approached. Participants completed a screening questionnaire for co-morbidities linked to kidney dysfunction and consented to have a PoC and laboratory creatinine tests. Comparison was made against with previous baseline blood tests obtained within the preceding 3 months, as required by the study site. Participants were also invited to attend for follow up PoC and laboratory bloods tests at 48-72 h.

RESULTS: 14 patients (4.7%) had a scan-day eGFR below 45mL/min/1.73m2, all identified through screening. The majority of patients (n=281/300; 93.7%) fell in the same risk category based on previous and scan-day blood results. Six PoC test failures were recorded on the scan day. The constant error between the Abbott i-STAT PoC scan-day measurements and the laboratory scan-day measurements was -3.71 (95% CI: -6.41 to -0.50). Five patients had an elevated creatinine (≥25% from baseline) post contrast administration, but no instances of PC-AKI (≥50% from baseline) were identified.

CONCLUSION: PoC creatinine testing is a practical method of ensuring renal function and is feasible in the radiology environment.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Snaith B, Harris MA, Shinkins B, et al. Point of care creatinine testing in diagnostic imaging: A feasibility study within the outpatient computed tomography setting. Eur J Radiol. 2019. PMID: 30777224. doi:10.1016/j.ejrad.2019.01.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。