评估用于确定病理包膜接触长度的最优多参数磁共振成像序列
本回顾性研究纳入105例前列腺癌患者,比较T2WI、ADC图和DCE-MRI测量包膜接触长度(LCC)与病理LCC的相关性及诊断前列腺癌包膜外侵犯(EPE)的效能。DCE-MRI基于LCC预测病理LCC的AUC最高,但T2WI与DCE-MRI诊断EPE的准确性相近。
要点
- DCE-MRI测量的LCC与病理LCC相关性最强,预测病理LCC的AUC高于T2WI和ADC图。
- T2WI和DCE-MRI基于LCC诊断EPE的准确性均为中等,两者表现相似。
- ADC图基于LCC诊断EPE的准确性较差,且EPE与非EPE患者LCC重叠更明显。
核心结论
- 前列腺肿瘤与包膜的接触似乎是评估多参数MRI诊断前列腺癌EPE的有用且客观的参数;基于DCE-MRI的LCC与病理LCC相关性最高,预测病理LCC的能力优于其他序列,但T2WI与DCE-MRI基于LCC诊断EPE的效能相似。
研究设计与样本
- 回顾性研究纳入105例根治性前列腺切除术前接受前列腺多参数MRI的前列腺癌患者。
- 由两名盲法放射科医师分别从T2WI、ADC图和DCE-MRI测量LCC。
- 以根治性前列腺切除术后病理LCC为参考标准,采用Mann-Whitney U检验、Spearman检验和ROC曲线分析。
关键影像表现/征象
- 有EPE与无EPE患者相比,各多参数MRI序列测量的中位LCC均更长(两名阅片者一致)。
- ADC图上LCC在有无EPE患者间的重叠较T2WI和DCE-MRI更宽(阅片者1 P=0.01,阅片者2 P=0.01;T2WI阅片者1 P=0.002,阅片者2 P=0.001;DCE-MRI阅片者1 P=0.001,阅片者2 P=0.001)。
诊断标准与关键数值
- DCE-MRI基于LCC预测病理LCC的AUC:阅片者1为0.874(P=0.030),阅片者2为0.862(P=0.02),高于T2WI和ADC图。
- 基于LCC诊断EPE:T2WI和DCE-MRI为中等诊断准确性,ADC图为较差诊断准确性。
临床应用与阅片要点
- 作者认为前列腺肿瘤与包膜的接触似乎是评估EPE的有用且客观的参数。
- 作者认为从DCE-MRI和从T2WI测量LCC在临床EPE评估中似乎没有差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the most optimal multi-parametric magnetic resonance imaging sequence (Mp-MRI) in determining pathological length of capsular contact (LCC) for the diagnosis of prostate cancer extraprostatic extension (EPE).
METHODS: 105 patients with prostate cancer who underwent Mp-MRI of prostate prior to radical prostatectomy were enrolled in this retrospective study. LCC was determined from T2-weighted images (T2WI), Apparent Diffusion Coefficient (ADC) map, dynamic contrast-enhanced MRI (DCE-MRI) separately by two blinded radiologists. The LCCs in patients with and without EPE were compared with Mann Whitney-U test. The relationship between pathological LCC and the LCC that was measured from each Mp-MRI sequences were calculated by using Spearman test. The ability of all individual Mp-MRI sequences in determining pathological LCC was calculated by drawing receiver operator characteristic (ROC) curves. The diagnostic accuracy of LCC based on each MRI sequences for EPE diagnosis was also calculated with ROC curve analysis.
RESULTS: The patients with EPE had longer median LCC than patients without EPE for each Mp-MRI sequences and for both readers. In addition, the LCC showed a broader overlapping between patients with and without EPE on ADC map (reader-1, p = 0.01; reader-2, p = 0.01) when compared with T2WI (reader-1, p = 0.002; reader-2, p = 0.001) and DCE-MRI (reader-1, p = 0.001; reader-2, p = 0.001). LCC based on DCE-MRI showed the strongest correlation with pathological LCC. The area under the curve (AUC) based on LCC was higher when using the DCE-MRI (reader-1: 0.874, p = 0.030; reader-2: 0.862, p = 0.02) than when using T2WI and ADC map in predicting pathological LCC for both readers. While the LCC based on ADC map showed poor diagnostic accuracy, LCC based on T2WI and DCE-MRI had fair diagnostic accuracy for EPE diagnosis.
CONCLUSION: The contact between prostate tumor and capsule seems to be a useful and objective parameter for evaluating the EPE of prostate cancer with Mp-MRI. More specifically, LCC based on DCE-MRI has highest correlation with pathological LCC and has better ability to predict pathological LCC when compared with other Mp-MRI sequences. However, the performance of LCC based on T2WI and DCE-MRI was similar for EPE diagnosis. It seems measurement of LCC from DCE-MRI and measurement of LCC from T2WI does not show any difference in clinical EPE assessment.
引用
- Onay A, Vural M, Armutlu A, et al. Evaluation of the most optimal multiparametric magnetic resonance imaging sequence for determining pathological length of capsular contact. Eur J Radiol. 2019. PMID: 30777210. doi:10.1016/j.ejrad.2019.01.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。