文献速递泌尿生殖腹部MR

背景信号强度变化对前列腺MRI癌症检测的影响

The Influence of Background Signal Intensity Changes on Cancer Detection in Prostate MRI.
PubMed 文献 · AJR Am J Roentgenol · 2019-02-04

这项回顾性研究纳入418例前列腺MRI检查(385例男性),评估T2加权序列上背景信号强度变化或前列腺均匀性评分(1-5分)对癌症检测的影响。两名阅片者间一致性为κ=0.783,信号均匀性评分越高,前列腺癌和临床显著癌(Gleason评分≥3+4)的敏感度越高,但一名阅片者的特异度显著下降。结论认为背景信号强度变化显著限制前列腺癌检测。

要点

  • T2加权序列上背景信号强度变化越广泛(均匀性评分越低),前列腺癌检测敏感度越低。
  • 信号均匀性评分越高,临床显著癌(Gleason评分≥3+4)敏感度也越高,但特异度可能下降。
  • 所提出的1-5分均匀性评分系统阅片者间一致性为κ=0.783,可能有助于标准化前列腺MRI报告。

核心结论

  • T2加权图像上的背景信号强度变化显著限制前列腺癌检测;所提出的评分系统可能改善前列腺MRI报告的标准化,并为在临床决策中适当应用前列腺MRI结果提供指导。

研究设计与样本

  • 经机构审查委员会批准、符合HIPAA的回顾性研究,纳入385例男性的418次前列腺MRI检查,这些男性随后接受了MRI引导下活检;以活检芯的组织病理学检查为参考标准。

关键影像表现/征象

  • 两名阅片者评估T2加权序列上信号变化量,并赋予预定义的前列腺信号强度均匀性评分1-5分(1分=差、广泛变化;5分=优、无变化)。

诊断标准与关键数值

  • 信号强度均匀性评分阅片者间一致性为κ=0.783。
  • 前列腺癌检测敏感度随评分升高而增加:阅片者1从0.41升至0.71,阅片者2从0.53升至0.73,两名阅片者均p≤0.007。
  • 临床显著癌(Gleason评分≥3+4)检测敏感度随评分升高而增加:阅片者1从0.50升至0.82,阅片者2从0.63升至0.86,p≤0.028。
  • 一名阅片者的特异度显著下降:从0.67降至0.38,p=0.009。

临床应用与阅片要点

  • 原文结论认为背景信号强度变化显著限制前列腺癌检测。
  • 原文认为所提出的评分系统可能改善前列腺MRI报告的标准化,并为在临床决策中适当应用前列腺MRI结果提供指导。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study was to develop a scoring system for background signal intensity changes or prostate homogeneity on prostate MRI and to assess these changes' influence on cancer detection.

MATERIALS AND METHODS: This institutional review board-approved, HIPAA-compliant, retrospective study included 418 prostate MRI examinations in 385 men who subsequently underwent MRI-guided biopsy. The Likert score for suspicion of cancer assigned by the primary radiologist was extracted from the original report, and histopathologic work-up of the biopsy cores served as the reference standard. Two readers assessed the amount of changes on T2-weighted sequences and assigned a predefined prostate signal-intensity homogeneity score of 1-5 (1 = poor, extensive changes; 5 = excellent, no changes). The sensitivity and specificity of Likert scores for detection of prostate cancer and clinically significant cancer (Gleason score ≥ 3+4) were estimated in and compared between subgroups of patients with different signal-intensity homogeneity scores (≤ 2, 3, and ≥ 4).

RESULTS: Interreader agreement on signal-intensity homogeneity scores was substantial (κ = 0.783). Sensitivity for prostate cancer detection increased when scores were better (i.e., higher) (reader 1, from 0.41 to 0.71; reader 2, from 0.53 to 0.73; p ≤ 0.007, both readers). In the detection of significant cancer (Gleason score ≥ 3+4), sensitivity also increased with higher signal-intensity scores (reader 1, from 0.50 to 0.82; reader 2, from 0.63 to 0.86; p ≤ 0.028), though specificity decreased significantly for one reader (from 0.67 to 0.38; p = 0.009).

CONCLUSION: Background signal-intensity changes on T2-weighted images significantly limit prostate cancer detection. The proposed scoring system could improve the standardization of prostate MRI reporting and provide guidance for applying prostate MRI results appropriately in clinical decision-making.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Hötker AM, Dappa E, Mazaheri Y, et al. The Influence of Background Signal Intensity Changes on Cancer Detection in Prostate MRI. AJR Am J Roentgenol. 2019. PMID: 30714830. doi:10.2214/AJR.18.20295

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。