文献速递泌尿生殖MR

不同经验阅片者使用双参数磁共振成像(bpMRI)检测前列腺癌:性能及与多参数(mpMRI)的比较

Prostate cancer detection with biparametric magnetic resonance imaging (bpMRI) by readers with different experience: performance and comparison with multiparametric (mpMRI).
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

回顾性分析68例患者的前列腺mpMRI(1.5T,32相控阵线圈),6名不同经验阅片者分别用bpMRI和mpMRI评估临床显著前列腺癌。专家阅片者bpMRI与mpMRI性能相当(敏感度0.91-0.96,AUC 0.86-0.93);300例经验者在mpMRI表现好但bpMRI显著下降(敏感度0.58 vs 0.91,AUC 0.73 vs 0.86);100例经验者两者均差。结论提示bpMRI对专家是有效替代,经验较少者需DCE,可靠判读bpMRI的阈值约700-800例。

要点

  • 专家阅片者bpMRI与mpMRI性能相当,敏感度0.91-0.96、AUC 0.86-0.93(p≥0.10)。
  • 300例经验者bpMRI敏感度0.58 vs mpMRI 0.91(p<0.0001),AUC 0.73 vs 0.86(p=0.01)。
  • 100例经验者mpMRI敏感度0.71、AUC 0.77,bpMRI敏感度0.50、AUC 0.68。

核心结论

  • 研究揭示了阅片者经验对bpMRI性能的影响;无对比剂的bpMRI对专家阅片者是有效替代,而经验较少者需要DCE才能显著提升敏感度和AUC;结果提示可靠判读bpMRI的阈值约为700-800例。

研究设计与样本

  • 回顾性分析68例患者的前列腺mpMRI(1.5 Tesla,32相控阵线圈);45例(病例)行根治性前列腺切除术,23例(对照)前列腺活检阴性且随访≥2.5年阴性;6名观察者(2名阅片1000例、2名300例、2名100例)先用bpMRI(DWI、ADC图、三平面T2W)分析,1个月后用mpMRI(加DCE)分析;以敏感度、特异度和ROC的AUC量化性能。

诊断标准与关键数值

  • 同等经验观察者间一致性良好(加权Cohen's k≈0.7)。
  • 2名专家阅片者bpMRI与mpMRI性能相当:敏感度0.91-0.96,AUC 0.86-0.93(p≥0.10)。
  • 300例经验者mpMRI表现好,但bpMRI显著更差:敏感度0.58 vs 0.91(p<0.0001),AUC 0.73 vs 0.86(p=0.01)。
  • 100例经验者mpMRI敏感度0.71、AUC 0.77,bpMRI敏感度0.50、AUC 0.68。
  • 结果提示可靠判读bpMRI的阈值约为700-800例。

临床应用与阅片要点

  • 专家阅片者可采用无对比剂的bpMRI作为mpMRI的有效替代。
  • 经验较少者需要DCE以显著提升敏感度和AUC。
  • 可靠判读bpMRI的阈值约为700-800例。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To study the detection of clinically significant prostate cancer (PCa) by readers with different experience, comparing performance with biparametric magnetic resonance imaging (bmMRI) and with the reference multiparametric (mpMRI).

METHODS: Retrospective analysis of 68 patients with mpMRI of the prostate at 1.5 Tesla using a 32 phased-array coil. Forty-five patients (cases) underwent radical prostatectomy, whereas 23 (controls) had a negative prostate biopsy and ≥ 2.5 years of negative follow-up. Six observers (two with 1000 cases interpreted, two with 300, two with 100) performed the analysis first with bpMRI including diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC) maps and T2-weighted (T2W) imaging in three planes and, after 1 month, with mpMRI, adding dynamic contrast enhancement (DCE). The performance was quantified by sensitivity (SNS), specificity (SPC) and area under the curve (AUC) of the ROC (Receiver Operating Characteristics) procedure.

RESULTS: Concordance within observers of equivalent experience was good (weighted Cohen's k ≈ 0.7). The two expert readers performed as well in bpMRI as in mpMRI (SNS = 0.91-0.96, AUC = 0.86-0.93; p ≥ 0.10); readers with 300 cases performed well in mpMRI, but significantly worse in bpMR: SNS = 0.58 versus 0.91 (p < 0.0001) and AUC = 0.73 versus 0.86 (p = 0.01); the limited experience of readers with 100 cases showed in mpMRI (SNS = 0.71; AUC = 0.77) and even more in bpMRI (SNS = 0.50; AUC = 0.68).

CONCLUSION: The study revealed the impact of the readers' experience when using bpMRI. The bpMRI without contrast media was a valid alternative for expert readers, whereas less experienced ones needed DCE to significantly boost SNS and AUC. Results indicate 700-800 cases as threshold for reliable interpretation with bpMRI.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Gatti M, Faletti R, Calleris G, et al. Prostate cancer detection with biparametric magnetic resonance imaging (bpMRI) by readers with different experience: performance and comparison with multiparametric (mpMRI). Abdom Radiol (NY). 2019. PMID: 30788558. doi:10.1007/s00261-019-01934-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。