双能量CT评估肾脏肿块的诊断准确性:系统评价与Meta分析
该系统评价与Meta分析纳入5项研究共367例患者,评估双能量CT碘定量对肾脏肿块定性的诊断准确性。汇总敏感度和特异度分别为96.6%(95%CI 85.9-99.3%)和95.1%(95%CI 90.7-97.5%),双能量CT与传统CT的准确性无显著差异(p=0.06)。作者认为双能量CT碘定量可能作为传统CT的替代方法,但需更大规模试验证实。
要点
- 双能量CT碘定量评估肾脏肿块汇总敏感度96.6%、特异度95.1%。
- 双能量CT与传统CT的诊断准确性无显著差异(p=0.06)。
- 纳入研究数量少且多数存在偏倚风险,结论需谨慎解读。
核心结论
- 双能量CT碘定量对肾脏肿块评估的敏感度和特异度均大于95%,可能作为传统CT的替代方法。
研究设计与样本
- 系统评价与Meta分析,检索MEDLINE、Embase和Cochrane Central Register of Controlled Trials数据库(1947-2018年)。
- 纳入5项研究共367例患者,纳入标准为评估不确定肾脏肿块患者定量碘浓度的研究。
- 参考标准为组织病理学分析或随访影像。
- 采用QUADAS-2评估偏倚风险和适用性,双变量随机效应模型确定汇总敏感度和特异度。
诊断标准与关键数值
- 双能量CT碘定量评估肾脏肿块的汇总敏感度为96.6%(95%CI 85.9-99.3%)。
- 双能量CT碘定量评估肾脏肿块的汇总特异度为95.1%(95%CI 90.7-97.5%)。
- Meta回归评估检查类型(双能量CT vs 传统CT)的影响未发现准确性差异(p=0.06)。
- 基于偏倚风险或双能量CT技术的亚组分析未发现准确性差异。
临床应用与阅片要点
- 作者认为双能量CT碘定量可能作为传统CT评估肾脏肿块的替代方法。
- 作者指出需要更大规模试验来证实该研究发现。
局限性
- 局限性包括纳入研究数量少,且大多数研究存在偏倚风险。
- 作者指出需要更大规模试验来证实研究发现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study is to determine the diagnostic accuracy of dual-energy CT (DECT) using quantitative iodine concentration in patients with renal masses using histopathologic analysis or follow-up imaging as the reference standard. The secondary objective is to compare the accuracy of DECT (using iodine concentration) to that of conventional CT (using Hounsfield unit measurements).
MATERIALS AND METHODS: We searched the MEDLINE, Embase, and Cochrane Central Register of Controlled Trials databases for studies evaluating the accuracy of DECT for renal mass characterization (1947-2018). To be included, studies had to evaluate quantitative iodine concentrations in human patients with indeterminate renal masses. Risk of bias and applicability were assessed using quality assessment of diagnostic accuracy studies-2. A bivariate random-effects model was used to determine pooled sensitivity and specificity. Variability was assessed by subgroup analyses (DECT technique and risk of bias) and metaregression using test type and threshold applied as covariates.
RESULTS: Of 201 studies identified, five were included (367 patients). Pooled sensitivity and specificity for DECT were 96.6% (95% CI, 85.9-99.3%) and 95.1% (95% CI, 90.7-97.5%), respectively. Metaregression evaluating the influence of the test type (DECT vs conventional CT) did not identify differences in accuracy (p = 0.06). No differences in accuracy based on risk of bias or DECT technique were identified. Limitations include the small number of studies, most of which were at risk of bias.
CONCLUSION: DECT with iodine quantification shows sensitivity and specificity greater than 95% for evaluation of renal masses and may be an alternative to conventional CT for assessment of renal masses. Larger scale trials are needed to corroborate our findings.
引用
- Salameh JP, McInnes MDF, McGrath TA, et al. Diagnostic Accuracy of Dual-Energy CT for Evaluation of Renal Masses: Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2019. PMID: 30714831. doi:10.2214/AJR.18.20527
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。