文献速递腹部技术与安全CT

腹部CT全模型迭代重建(MBIR)提高客观图像质量但降低主观接受度

Full model-based iterative reconstruction (MBIR) in abdominal CT increases objective image quality, but decreases subjective acceptance.
PubMed 文献 · Eur Radiol · 2019-01-30

研究在320排CT上以7种剂量水平采集腹部图像,比较FBP、全混合迭代重建(HIR)和全模型迭代重建(full MBIR)的客观图像质量与放射科医生主观接受度。全MBIR的对比噪声比和空间分辨率更高、低剂量下低对比度可探测性更好,但80%医生认为其整体外观和纹理不如HIR,50%医生诊断信心更差。

要点

  • 全MBIR的对比噪声比显著高于FBP和HIR(p<0.0015),高空间频率(>0.3 lp/mm)分辨率更高。
  • 低剂量水平下全MBIR低对比度可探测性更好、更多插入物被高置信度识别(p<0.0001)。
  • 全MBIR改变图像纹理,80%医生认为整体外观和纹理劣于HIR,50%医生诊断信心更差。

核心结论

  • 与传统迭代重建算法相比,全MBIR呈现更高的图像质量和低对比度可探测性,但放射科医生的接受度更差。

研究设计与样本

  • 研究为图像质量评估研究,使用320排CT扫描仪在7种不同剂量水平下采集图像。
  • 图像采用三种算法重建:滤波反投影(FBP)、全混合迭代重建(HIR)和全模型迭代重建(full MBIR)。

关键影像表现/征象

  • 全MBIR的对比噪声比显著高于其他算法(p<0.0015)。
  • 全MBIR在高频(>0.3 lp/mm)空间分辨率也更高。
  • 低剂量水平下全MBIR低对比度可探测性更好,更多插入物被更高置信度识别(p<0.0001)。
  • 与HIR和FBP相比,全MBIR伴随图像纹理改变。

诊断标准与关键数值

  • 全MBIR的对比噪声比显著高于其他算法(p<0.0015)。
  • 全MBIR在高频(>0.3 lp/mm)空间分辨率更高。
  • 低剂量水平下全MBIR低对比度可探测性更好,更多插入物被更高置信度识别(p<0.0001)。
  • 问卷可靠性可接受(Cronbach alpha 0.7)。

临床应用与阅片要点

  • 80%的放射科医生判断全MBIR图像的整体外观和纹理劣于HIR。
  • 与HIR相比,50%的放射科医生对全MBIR图像的诊断信心更差。
  • 作者指出,认识到图像纹理改变和全MBIR重建图像质量提高,可能改善该技术在临床实践中的接受度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Evaluate and compare the image quality and acceptance of a full MBIR algorithm to that of an earlier full IR hybrid algorithm and filtered back projection (FBP).

METHODS: Acquisitions were performed with a 320 detector-row CT scanner with seven different dose levels. Images were reconstructed with three algorithms: FBP, full hybrid iterative reconstruction (HIR), and a full model-based iterative reconstruction algorithm (full MBIR). The sensitometry, spatial resolution, image texture, and low-contrast detectability of these algorithms were compared. Subjective analysis of low-contrast detectability was performed. Ten radiologists answered a questionnaire on image quality and confidence in full MBIR images in clinical practice.

RESULTS: The contrast-to-noise ratio of full MBIR was significantly higher than in the other algorithms (p < 0.0015). The spatial resolution was also higher with full MBIR at high frequencies (> 0.3 lp/mm). Full MBIR at low dose levels led to better low-contrast detectability and more inserts being identified with a higher confidence (p < 0.0001). Full MBIR was associated with a change in image texture compared to HIR and FBP. Eighty percent of radiologists judged general appearance and texture of full MBIR images worse than HIR. Moreover, compared with HIR, for 50% of radiologists, the diagnostic confidence on full MBIR images was worse. Questionnaire reliability was considered acceptable (Cronbach alpha 0.7).

CONCLUSION: Compared to conventional iterative reconstruction algorithms, full MBMIR presented a higher image quality and low-contrast detectability and a worse acceptance among radiologists.

KEY POINTS: • Full MBIR used led to an overall improvement in image quality compared with FBP and HIR. • Full MBIR leads to image texture change which reduces the confidence in these images among radiologists. • Awareness of the image texture change and improved quality of full MBIR reconstructed images could improve the acceptance of this technique in clinical practice.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Laurent G, Villani N, Hossu G, et al. Full model-based iterative reconstruction (MBIR) in abdominal CT increases objective image quality, but decreases subjective acceptance. Eur Radiol. 2019. PMID: 30701327. doi:10.1007/s00330-018-5988-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。