肝移植术后多普勒超声异常患者肝动脉闭塞:对比增强超声诊断的敏感度提升
在7年间2679例成人肝移植中,288例因多普勒超声怀疑肝动脉闭塞,其中130例接受对比增强超声(CEUS),排除2例技术失败后回顾性分析128例图像。以手术、血管造影或随访异常确诊肝动脉闭塞41例。采用改良标准(无肝动脉增强、异常增强或肝实质灌注缺损)较传统标准(无肝动脉增强)显著提高敏感度(97.6%对58.5%)和AUC(0.959对0.793),特异度略降(95.4%对100%)。
要点
- 改良CEUS标准(无增强、异常增强或灌注缺损)诊断肝动脉闭塞敏感度97.6%、AUC 0.959。
- 传统标准(仅无肝动脉增强)敏感度58.5%、特异度100%、AUC 0.793。
- 多普勒呈迟缓细流型肝动脉者,改良标准敏感度100%、特异度95.3%。
核心结论
- 改良标准可提高CEUS诊断肝动脉闭塞的效能,尤其提升敏感度;对多普勒超声呈迟缓细流型肝动脉的患者,采用改良标准CEUS仍有助于诊断肝动脉闭塞。
研究设计与样本
- 回顾性分析7年间2679例成人肝移植中288例多普勒超声怀疑肝动脉闭塞者,其中130例接受CEUS,排除2例技术失败后纳入128例CEUS图像;以手术、血管造影或随访异常为参考标准。
关键影像表现/征象
- CEUS异常表现包括无肝动脉增强、异常肝动脉增强(延迟、微弱、不连续增强)及肝实质灌注缺损。
- 按多普勒超声异常分为A组(无血流)和B组(迟缓细流型)。
诊断标准与关键数值
- 传统标准(无肝动脉增强)诊断肝动脉闭塞:敏感度58.5%、特异度100%、AUC 0.793。
- 改良标准(无肝动脉增强、异常增强或肝实质灌注缺损)诊断肝动脉闭塞:敏感度97.6%(40/41)、特异度95.4%(83/87)、AUC 0.959,敏感度与AUC较传统标准显著提高(p < 0.001)。
- A组(无血流)改良标准:敏感度97.1%(33/34)、特异度95.7%(22/23)。
- B组(迟缓细流型)改良标准:敏感度100%(7/7)、特异度95.3%(61/64)。
临床应用与阅片要点
- 对多普勒超声怀疑肝动脉闭塞者,CEUS判读可同时关注无肝动脉增强、异常增强及肝实质灌注缺损。
- 多普勒超声呈迟缓细流型肝动脉时,采用改良标准CEUS有助于诊断肝动脉闭塞。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate whether diagnostic performance of contrast-enhanced ultrasound (CEUS) could be improved with modified criteria to diagnose significant hepatic artery occlusion (HAO) and to determine the role of CEUS in patients with a tardus-parvus hepatic artery (HA) pattern on Doppler US.
MATERIALS AND METHODS: Among 2679 adult liver transplantations performed over 7 years, HAO was suspected in 288 recipients, based on Doppler ultrasound. Among them, 130 patients underwent CEUS. After excluding two technical failures, 128 CEUS images were retrospectively reviewed to search for abnormal findings, such as no HA enhancement, abnormal HA enhancement (delayed, faint, and discontinuous enhancement), and perfusion defect in the liver parenchyma. The performance CEUS abnormalities were assessed in the patients overall and in subgroups based on Doppler ultrasound abnormality (group A, no flow; group B, tardus-parvus pattern) and were compared based on the area under the receiver operating characteristic curve (AUC).
RESULTS: HAO were diagnosed in 41 patients by surgery, angiography, or follow-up abnormality. By using the conventional criterion (no HA enhancement) to diagnose HAO in patients overall, the sensitivity, specificity, and AUC were 58.5%, 100%, and 0.793, respectively. Modified criteria for HAO (no HA enhancement, abnormal enhancement, or parenchymal perfusion defect) showed statistically significantly increased sensitivity (97.6%, 40/41) and AUC (0.959) (p < 0.001), although the specificity (95.4%, 83/87) was slightly decreased. The sensitivity and specificity of the modified criteria in Groups A and B were 97.1% (33/34) and 95.7% (22/23), and 100% (7/7) and 95.3% (61/64), respectively.
CONCLUSION: Modified criteria could improve diagnostic performance of CEUS for HAO, particularly by increasing sensitivity. CEUS could be useful for diagnosing HAO even in patients with a tardus-parvus HA pattern on Doppler US, using modified criteria.
引用
- Kim JS, Kim KW, Choi SH, et al. Hepatic Artery Occlusion after Liver Transplantation in Patients with Doppler Ultrasound Abnormality: Increasing Sensitivity of Contrast-Enhanced Ultrasound Diagnosis. Korean J Radiol. 2019. PMID: 30799577. doi:10.3348/kjr.2018.0464
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。