文献速递腹部MR

3特斯拉肝脏磁共振弹性成像:梯度回波与自旋回波平面回波序列的比较及硬度测量的一致性

MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

在3特斯拉下对387例连续患者行2D-GRE和2D-SE-EPI磁共振弹性成像,比较肝脏硬度测量的一致性及诊断效能;2D-SE-EPI技术失败率较低,两种序列诊断效能相当,2D-GRE自由手测量敏感度最高、最大硬度测量特异度最高。

要点

  • 2D-SE-EPI技术失败率2.8%(11/387),低于2D-GRE的4.1%(16/387)。
  • 两种序列重复性均高(ICC=0.84-0.94)。
  • 鉴别轻度和进展期纤维化,2D-GRE自由手测量敏感度0.84最高,最大硬度测量特异度0.92最高。

核心结论

  • 2D-GRE与2D-SE-EPI磁共振弹性成像测量肝脏硬度均具有高组内和读片者内相关性,2D-SE-EPI失败率较低,两种序列诊断效能相当,2D-GRE自由手测量敏感度最高,2D-GRE最大硬度测量特异度最高。

研究设计与样本

  • 在3特斯拉下对387例连续患者行2D-GRE和2D-SE-EPI肝脏磁共振弹性成像,由两名独立读片者测量平均肝脏硬度、最大肝脏硬度和自由手肝脏硬度,并与97例活检患者的METAVIR纤维化评分相关,用受试者工作特征分析比较诊断效能。

诊断标准与关键数值

  • 鉴别轻度纤维化(F0-F2)与进展期纤维化(F3-F4)的最高敏感度为0.84(2D-GRE自由手测量),最高特异度为0.92(2D-GRE最大硬度测量),最高准确度为0.88(2D-GRE自由手测量)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare 2D gradient-recalled echo (GRE) and 2D spin-echo (SE) echo-planar imaging (EPI) MR elastography (MRE) for measurement of hepatic stiffness in adult patients with known or suspected liver disease at 3 Tesla.

MATERIALS AND METHODS: Three hundred and eighty-seven consecutive patients underwent MRE of the liver at 3 Tesla with 2D-GRE and 2D-SE-EPI sequences. 'Mean liver stiffness (LS)' calculated by averaging 3 ROIs in the right lobe, 'Maximum LS' calculated by an ROI in the right lobe; and 'Freehand LS' calculated by an ROI in the entire liver were measured by two independent readers. Inter-observer and inter-class variability in stiffness measurements were assessed. Stiffness values were correlated with degree of liver fibrosis (METAVIR scores) in 97 patients who underwent biopsy. The diagnostic performance was compared by a receiver-operating characteristic analysis.

RESULTS: The technical failure rate was 2.8% for 2D-SE-EPI (11/387) and 4.1% for 2D-GRE (16/387, 9 had R2* > 80 s-1 indicating iron overload). There is high reproducibility for both GRE and SE-EPI variants (ICC = 0.84-0.94 for both GRE and SE-EPI MRE). The highest sensitivity, specificity, and accuracy of differentiating mild fibrosis (F0-F2) from advanced fibrosis (F3-F4) are 0.84 (GRE Freehand measurement), 0.92 (GRE Maximum stiffness measurement), and 0.88 (GRE Freehand measurement), respectively.

CONCLUSIONS: High intra-class correlation and intra-reader correlation are seen on measured hepatic stiffness for both 2D-GRE and 2D-SE-EPI MRE. 2D-SE-EPI has lower failure rate. Diagnostic performance of both sequences is equivalent, with highest sensitivity for 2D-GRE Freehand stiffness measurement, and highest specificity 2D-GRE Maximum stiffness measurement.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zhan C, Kannengiesser S, Chandarana H, et al. MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements. Abdom Radiol (NY). 2019. PMID: 30796479. doi:10.1007/s00261-019-01932-5