儿童正常阑尾的可视化:单次对比增强径向梯度回波MRI序列的可行性
这项回顾性研究纳入7–18岁接受腹盆腔对比增强MRI的患者,比较对比增强径向GRE与对比增强3-D GRE及包含径向GRE的多序列方案对正常阑尾的检出率。对比增强径向GRE检出率显著高于对比增强3-D GRE(76% vs 57.3%,P=0.003),径向GRE单独与多序列MRI间无显著差异(76% vs 81.3%,P=0.267)。
要点
- 对比增强径向GRE对正常阑尾检出率显著高于对比增强3-D GRE(76% vs 57.3%,P=0.003)。
- 包含径向GRE的多序列MRI检出率显著高于对比增强3-D GRE(81.3% vs 57%,P<0.001)。
- 径向GRE单独与包含径向GRE的多序列MRI检出率无显著差异(76% vs 81.3%,P=0.267)。
核心结论
- 对比增强径向GRE对正常阑尾的检出优于对比增强3-D GRE;径向GRE单独判读的检出率与结合其他序列判读接近。
研究设计与样本
- 回顾性研究,纳入2012年1月1日至2016年4月1日期间接受腹盆腔对比增强MRI的7–18岁患者,由两名儿科放射科医生共识评估阑尾可视化,采用McNemar检验比较各序列及序列组合的阑尾检出率。
诊断标准与关键数值
- 对比增强径向GRE对正常阑尾检出率为76%,对比增强3-D GRE为57.3%(P=0.003)。
- 包含对比增强径向GRE的多序列MRI对正常阑尾检出率为81.3%,对比增强3-D GRE为57%(P<0.001)。
- 对比增强径向GRE单独与包含径向GRE的多序列MRI检出率分别为76%与81.3%(P=0.267)。
临床应用与阅片要点
- 对比增强径向GRE为自由呼吸、运动稳健序列,可能有助于儿童阑尾评估。
- 作者结论认为对比增强径向GRE对正常阑尾的检出优于对比增强3-D GRE。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Magnetic resonance imaging (MRI) assessment for appendicitis is limited by exam time and patient cooperation. The radially sampled 3-dimensional (3-D) T1-weighted, gradient recalled echo sequence (radial GRE) is a free-breathing, motion robust sequence that may be useful in evaluating appendicitis in children.
OBJECTIVE: To compare the rate of detection of the normal appendix with contrast-enhanced radial GRE versus contrast-enhanced 3-D GRE and a multi-sequence study including contrast-enhanced radial GRE.
MATERIALS AND METHODS: This was a retrospective study of patients ages 7-18 years undergoing abdominal-pelvic contrast-enhanced MRI between Jan. 1, 2012, and April 1, 2016. Visualization of the appendix was assessed by consensus between two pediatric radiologists. The rate of detection of the appendix for each sequence and combination of sequences was compared using a McNemar test.
RESULTS: The rate of detection of the normal appendix on contrast-enhanced radial GRE was significantly higher than on contrast-enhanced 3-D GRE (76% vs. 57.3%, P=0.003). The rate of detection of the normal appendix with multi-sequence MRI including contrast-enhanced radial GRE was significantly higher than on contrast-enhanced 3-D GRE (81.3% vs. 57%, P<0.001). There was no significant difference between the rate of detection of the normal appendix on contrast-enhanced radial GRE alone and multi-sequence MRI including contrast-enhanced radial GRE (76% vs. 81.3%, P=0.267).
CONCLUSION: Contrast-enhanced radial GRE allows superior detection of the normal appendix compared to contrast-enhanced 3-D GRE. The rate of detection of the normal appendix on contrast-enhanced radial GRE alone is nearly as good as when the contrast-enhanced radial GRE is interpreted with additional sequences.
引用
- Lala SV, Strubel N, Nocera N, et al. Visualization of the normal appendix in children: feasibility of a single contrast-enhanced radial gradient recalled echo MRI sequence. Pediatr Radiol. 2019. PMID: 30783687. doi:10.1007/s00247-019-04352-1