文献速递腹部MR

表观扩散系数在鉴别浆液性与产黏液性胰腺囊性肿瘤中的附加价值

Added value of apparent diffusion coefficient in distinguishing between serous and mucin-producing pancreatic cystic neoplasms.
PubMed 文献 · Eur Radiol · 2019-02-14

纳入117例最大径≥10 mm的胰腺囊性肿瘤患者,三位阅片者分别独立评估使用与不使用表观扩散系数(ADC)的MRI。使用ADC使三位阅片者鉴别浆液性与产黏液性肿瘤的诊断信心均提高(p<0.001),且两位经验较少的阅片者诊断准确率提高(87.2% vs. 80.8%;91.5% vs. 80.8%)。弥散加权成像(DWI)可能作为常规形态学MRI的补充工具,对腹部MRI阅片经验较少的读者可能价值更大。

要点

  • DWI/ADC可使三位阅片者鉴别浆液性与产黏液性胰腺囊性肿瘤的诊断信心分别提高44.8%、73.6%、78.2%。
  • 使用ADC后诊断信心提高的比值比随阅片经验减少分别为5.8、6.8、12.7。
  • 两位经验较少的阅片者使用ADC后诊断准确率分别为87.2% vs. 80.8%和91.5% vs. 80.8%。

核心结论

  • DWI可能作为常规形态学MRI的补充工具用于鉴别浆液性与产黏液性胰腺囊性肿瘤,对腹部MRI阅片经验较少的读者可能价值更大。

研究设计与样本

  • 纳入117例最大径≥10 mm的胰腺囊性肿瘤患者,三位阅片者独立评估使用与不使用ADC的MRI,采用逻辑回归分析诊断信心评分差异并比较诊断性能。

诊断标准与关键数值

  • 三位阅片者使用DWI/ADC后鉴别浆液性与产黏液性胰腺囊性肿瘤的诊断信心分别提高44.8%、73.6%、78.2%。
  • 三位阅片者使用ADC后诊断信心提高的比值比随阅片经验减少分别为5.8、6.8、12.7,使用ADC较形态学成像获得更高诊断信心的概率增加(p<0.001)。
  • 两位经验较少的阅片者使用ADC的形态学MRI诊断准确率高于不使用ADC(87.2% vs. 80.8%;91.5% vs. 80.8%)。

临床应用与阅片要点

  • 作者认为DWI可能作为常规形态学MRI的补充工具,用于鉴别浆液性与产黏液性胰腺囊性肿瘤。
  • 作者认为DWI对腹部MRI阅片经验较少的读者可能价值更大。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the added value of diffusion-weighted imaging (DWI) on MRI in differentiating serous from mucin-producing pancreatic cystic neoplasms (PCNs).

METHODS: One hundred seventeen patients with PCN measuring ≥ 10 mm were included. Three readers independently evaluated MRI with and without the use of apparent diffusion coefficient (ADC). Logistic regression was used to analyze whether confidence scores were different with the use of different image sets. Diagnostic performance with and without ADC was compared.

RESULTS: DWI/ADC improved confidence in 44.8%, 73.6%, and 78.2% of patients by the three readers in distinguishing serous from mucin-producing PCNs. The use of ADC increased the probability of a higher confidence in the differentiation as compared to morphological imaging for all three readers (p < 0.001). Odds ratio for increase in the diagnostic confidence with the use of ADC for the three readers with decreasing years of experience were 5.8, 6.8, and 12.7. The diagnostic accuracy of morphological MRI with ADC was higher than that without ADC for two of three readers with lesser experience (87.2% vs. 80.8%; 91.5% vs. 80.8%).

CONCLUSION: DWI may have added value as a complementary tool to conventional morphological MRI in differentiating between serous and mucin-producing PCNs with possibly greater value for readers with less experience in reading abdominal MRI.

KEY POINTS: • Optimal management of PCNs requires differentiation of serous from mucin-producing PCNs. • ADC measurements allow increased confidence in differentiating serous from mucin-producing PCNs. • ADC measurements increase the accuracy in diagnosing serous versus mucin-producing PCNs.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Pandey P, Pandey A, Shao N, et al. Added value of apparent diffusion coefficient in distinguishing between serous and mucin-producing pancreatic cystic neoplasms. Eur Radiol. 2019. PMID: 30762111. doi:10.1007/s00330-019-6010-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。