超声心动图功能正常患者的高帧率应变定量参数
研究用高帧率超声心动图(最高2500帧/秒)对17例超声心动图功能正常患者行心尖四腔切面成像,以斑点追踪算法分析左心室六个区域应变曲线并定义四个机械事件;发现心肌组织缩短起始时间在不同节段间差异有统计学意义(p < 0.01),空间起点位于室间隔中部附近。
要点
- 高帧率超声(500-1000帧/秒)可定量左心室纵向应变并定义四个机械事件的时间序列。
- 功能正常者心肌组织缩短起始时间在左心室不同节段间存在统计学显著差异(p < 0.01)。
- 组织缩短的空间起点位于室间隔中部附近,各事件相对Q波的时间模式可能成为评估心功能的新指标。
核心结论
- 基于高帧率应变成像在超声心动图功能正常患者中定义的定量参数,可作为评估心肌收缩异常程度和识别收缩传播的基线,各事件相对Q波的时间模式可能成为评估心功能的新指标并可能改善诊断与预后。
研究设计与样本
- 研究论文;采用杜克大学相控阵超声系统T5采集17例超声心动图功能正常患者的心尖四腔切面高帧率图像,B型图像以接收16:1或32:1并行处理、扫描深度≤14 cm、80°视野、3.5 MHz 96阵元线阵探头在500-1000帧/秒下获取,图像用Aalborg与杜克大学开发的高帧率斑点追踪算法分析。
关键影像表现/征象
- 沿左心室心肌轮廓六个区域定义四个特定机械事件,应变曲线测量心肌局部形变事件且独立于整体心脏运动。
- 所描述的第一个机械事件即心肌组织缩短起始,在不同心肌节段间的时间序列差异有统计学意义(p < 0.01)。
- 在超声心动图功能正常患者中,组织缩短的空间起点位于室间隔中部附近。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Recently, we developed a high-frame-rate echocardiographic imaging system capable of acquiring images at rates up to 2500 per second. High imaging rates were used to quantify longitudinal strain parameters in patients with echocardiographically normal function. These data can serve as a baseline for comparing strain parameters in disease states. The derived timing data also reveal the propagation of mechanical events in the left ventricle throughout the cardiac cycle. High-frame-rate echocardiographic images were acquired from 17 patients in the apical four-chamber view using Duke University's phased array ultrasound system, T5. B-Mode images were acquired at 500-1000 images per second by employing 16:1 or 32:1 parallel processing in receive, a scan depth ≤14 cm and an 80° field of view with a 3.5-MegaHertZ (MHz), 96-element linear array. The images were analyzed using a speckle tracking algorithm tailored for high-frame-rate echocardiographic images developed at Aalborg and Duke University. Four specific mechanical events were defined using strain curves from six regions along the myocardial contour of the left ventricle. The strain curves measure the local deformation events of the myocardium and are independent of the overall cardiac motion. We observed statistically significant differences in the temporal sequence among different myocardial segments for the first mechanical event described, myocardial tissue shortening onset (p < 0.01). We found that the spatial origin of tissue shortening was located near the middle of the interventricular septum in patients with echocardiographically normal function. The quantitative parameters defined here, based on high-speed strain measurements in patients with echocardiographically normal function, can serve as a means of assessing degree of contractile abnormality in the myocardium and enable the identification of contraction propagation. The relative timing pattern among specific events with respect to the Q wave may become an important new metric in assessing cardiac function and may, in turn, improve diagnosis and prognosis.
引用
- Andersen MV, Moore C, Søgaard P, et al. Quantitative Parameters of High-Frame-Rate Strain in Patients with Echocardiographically Normal Function. Ultrasound Med Biol. 2019. PMID: 30773380. doi:10.1016/j.ultrasmedbio.2018.11.007